文献速递心血管外周血管CT

迭代重建算法在低kV CT血管造影(CTA)低对比剂用量下用于经导管主动脉瓣植入术(TAVI)术前规划中的诊断价值:图像质量与辐射剂量暴露

Diagnostic value of iterative reconstruction algorithm in low kV CT angiography (CTA) with low contrast medium volume for transcatheter aortic valve implantation (TAVI) planning: image quality and radiation dose exposure.
PubMed 文献 · Br J Radiol · 2018-08-13

前瞻性纳入79例TAVI候选患者,42例采用100 kV、50 ml对比剂、迭代重建的研究组方案,37例采用120 kV、100 ml对比剂、FBP重建的标准方案。研究组各测量点平均衰减值更高,图像质量主观评分两组无显著差异,平均辐射剂量较对照组降低20%。作者结论认为低kV低对比剂用量CTA方案可在高质量图像下完成TAVI规划并显著降低辐射剂量。

要点

  • 低kV(100 kV)低对比剂(50 ml)迭代重建CTA方案用于TAVI术前评估时,全主动脉7个节段管腔平均衰减值均高于标准方案。
  • 两组图像质量4分制主观评分无显著差异,研究组平均辐射剂量较对照组降低20%。
  • 作者认为该方案可降低对比剂用量,从而降低对比剂诱导肾病风险。

核心结论

  • 低kV低对比剂用量CTA方案用于TAVI术前规划可获得高质量图像,且与标准CTA方案相比辐射剂量显著降低。

研究设计与样本

  • 前瞻性研究,共纳入79例TAVI候选患者,均使用256层MDCT检查;研究组42例采用100 kV、全身回顾性心电门控、50 ml对比剂、迭代重建算法,对照组37例采用120 kV、胸部心电门控、100 ml对比剂、FBP重建。

关键影像表现/征象

  • 研究组方案在所有测量中均获得更高的平均衰减值(HU),高于标准方案。
  • 图像质量采用4分制评估,两组图像质量评分无显著差异。
  • 研究组平均辐射剂量值显著低于对照组,降低20%。

临床应用与阅片要点

  • 作者认为低kV CTA用于TAVI术前评估可实现辐射剂量暴露和对比剂用量的显著降低,减少对比剂诱导肾病风险。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE:: To evaluate image quality and radiation dose exposure of low-kV (100 kV) and low contrast medium (CM) volume CT angiography (CTA) in patients candidate to Transcatheter Aortic Valve Implantation (TAVI), in comparison with standard CTA protocol.

METHODS:: 79 patients candidate for TAVI were prospectively enrolled in this study and examined with 256-MDCT. 42 patients were evaluated using study-group protocol (100 kV; whole-body retrospective ECG-gating; with 50 ml of CM; iterative reconstruction algorithm) while 37 patients underwent a standard CTA study (120 kV; ECG-gating for chest; 100 ml of CM; FBP reconstruction). Overall image quality was evaluated using a 4-point scale. Vascular enhancement (HU) was then assessed in each patient by manually drawing multiple ROIs in lumen of 7 segments of the whole aorta. The radiation dose exposure of both groups was calculated and all data were compared and statistically analyzed.

RESULTS:: On low-kV protocol, higher mean attenuation values were achieved in all the measurements as compared to standard protocol. There were no significant differences in the image quality evaluation in both groups. Mean radiation dose value of study group was significantly lower than in control group (reduction of 20%).

CONCLUSION:: Low kV and low CM volume CTA protocols allow TAVI planning to be carried out with high quality images and a significant reduction in the radiation dose as compared to the standard CTA protocol.

ADVANCES IN KNOWLEDGE:: Low-kV CTA for pre-operative assessment of patients candidates for TAVI, permits to achieve a significant reduction of radiation dose exposure and contrast medium volume, reducing the risk of contrast induced nephropathy.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Talei Franzesi CR, Ippolito D, Riva L, et al. Diagnostic value of iterative reconstruction algorithm in low kV CT angiography (CTA) with low contrast medium volume for transcatheter aortic valve implantation (TAVI) planning: image quality and radiation dose exposure. Br J Radiol. 2018. PMID: 30074831. doi:10.1259/bjr.20170802

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。