以50%葡萄糖为造影剂的对比经胸超声心动图筛查卵圆孔未闭
本研究评估以50%葡萄糖为造影剂的对比经胸超声心动图(cTTE)筛查卵圆孔未闭(PFO)的可行性、优势、诊断敏感度和准确度,并与振荡生理盐水对比。结果显示50%葡萄糖产生的微泡峰值时间、有效持续时间及持续时间均长于生理盐水;生理盐水cTTE检出PFO的敏感度为83%(20/24),50%葡萄糖cTTE为100%(24/24),但两者差异无统计学显著意义。
要点
- 50%葡萄糖cTTE检出PFO敏感度100%(24/24),生理盐水cTTE为83%(20/24)。
- 50%葡萄糖微泡峰值时间、有效持续时间及持续时间均长于生理盐水。
- 两种造影剂cTTE检出PFO的敏感度差异无统计学显著意义。
核心结论
- 以50%葡萄糖为造影剂的cTTE便于超声技师观察PFO的右向左分流,但其检出PFO的敏感度与生理盐水cTTE相比无统计学显著差异。
研究设计与样本
- 研究评估50%葡萄糖与振荡生理盐水作为造影剂行cTTE筛查PFO的可行性、优势、诊断敏感度和准确度,以经食管超声心动图(TEE)提示PFO的24例患者为参照。
关键影像表现/征象
- 50%葡萄糖产生的微泡峰值时间、有效持续时间及持续时间均长于生理盐水产生的微泡。
- cTTE可观察到PFO的右向左分流。
诊断标准与关键数值
- 生理盐水cTTE检出PFO的敏感度为83%(20/24)。
- 50%葡萄糖cTTE检出PFO的敏感度为100%(24/24)。
- TEE在两组共24例患者中提示PFO。
- 两种造影剂cTTE检出PFO的敏感度差异无统计学显著意义。
临床应用与阅片要点
- 以50%葡萄糖为造影剂行cTTE检查便于超声技师观察PFO的右向左分流。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
A patent foramen ovale (PFO) is considered a risk factor for neurologic events. The goal of the study described here was to assess the feasibility, advantages, diagnostic sensitivity and accuracy of contrast transthoracic echocardiography examination (cTTE) using 50% glucose as a contrast agent in comparison with the use of agitated saline as contrast to screen for PFO. In our study, we found that the peak time, effective duration and duration of microbubbles produced by 50% glucose were all longer than those produced by the physiologic saline. The sensitivities for detection of PFO with cTTE using physiologic saline and 50% glucose as contrast were 83% (20/24) and 100% (24/24), respectively. TEE suggested a PFO in 24 patients in two groups. Use of 50% glucose as a contrast agent in cTTE examination enables ultrasound technicians to easily observe the right-to-left shunt across the PFO. However, the sensitivities for detection of PFO with cTTE using 50% glucose did not statistically significantly differ from those for physiologic saline.
引用
- Li X, Gao YH, Wu SZ, et al. Contrast Transthoracic Echocardiography Using 50% Glucose as a Contrast Agent for Screening of a Patent Foramen Ovale. Ultrasound Med Biol. 2018. PMID: 30077414. doi:10.1016/j.ultrasmedbio.2018.06.007