文献速递胸部外周血管CT

分次团注对比剂注射方案可提高胸部CT检查中胸部血管的可视化并降低辐射剂量

Split-bolus contrast injection protocol enhances the visualization of the thoracic vasculature and reduced radiation dose during chest CT.
PubMed 文献 · Br J Radiol · 2018-10-01

该回顾性研究纳入300例已知胸部恶性肿瘤患者,比较双团注方案(A方案)与多相注射方案(B方案)在胸部CT中的表现。B方案动脉强化较A方案最高增加24%(p<0.032),静脉强化显著降低且最大降幅达84%(p<0.0001),动静脉对比比(AVCR)显著改善(p<0.002),辐射剂量显著降低(p<0.004),ROC与VGC的Az评分均显著提高(p<0.0001),阅片者间一致性从差提升至优。

要点

  • B方案动脉强化较A方案最高增加24%,静脉强化最大降低84%,动静脉对比比显著改善。
  • B方案辐射剂量显著低于A方案,ROC与VGC的Az评分均显著高于A方案。
  • 两方案中心与外周肺动脉CT值均>263 HU,差异无统计学意义。

核心结论

  • 采用多相对比剂注射方案可显著改善胸部CT中胸部血管的强化程度及纵隔淋巴结的可视化。

研究设计与样本

  • 经机构审查委员会批准的回顾性研究,纳入300例已知胸部恶性肿瘤患者,分为A方案(双团注)与B方案(多相注射),比较胸部动静脉强化及动静脉对比比。

关键影像表现/征象

  • B方案动脉强化较A方案最高增加24%(p<0.032)。
  • B方案静脉强化显著低于A方案,最大降幅达84%(p<0.0001)。
  • 两方案中心与外周肺动脉CT值均>263 HU,差异无统计学意义。
  • B方案在多个解剖部位的动静脉对比比显著改善(p<0.002)。

诊断标准与关键数值

  • B方案较A方案辐射剂量显著降低(p<0.004)。
  • ROC与VGC分析显示B方案Az评分显著高于A方案(p<0.0001),阅片者间一致性从差提升至优。

临床应用与阅片要点

  • 多相注射方案使胸部动静脉强化更均匀,有助于区分血管与淋巴结。
  • 采用多相对比剂注射方案时可降低辐射剂量。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the visualization of mediastinal lymph nodes during thoracic CT employing a multiphasic contrast media (CM) protocol.

METHODS: Institutional review board approved retrospective study consisting of 300 patients with known chest malignancy. Patients were allocated to one of two CM protocols: Protocol A, consisted of dual bolus (Phase 1:100 ml CM followed by 100 ml saline chaser) i.v. injected at 2.5 ml s-1; Protocol B employed 100 ml of CM using a multiphasic injection protocol (Phase 1 and 2:60 ml contrast and saline, followed by Phase 3 and 4:40 ml contrast and saline injected at 2.5 ml s-1) with a fixed scan delay of 70 s for each acquisition. Attenuation profiles of the thoracic arteries and veins were calculated as well as the arterio-venous contrast ratios (AVCR). Receiver operating characteristic (ROC), visual grading characteristic (VGC), and Cohen's kappa analysis were assessed.

RESULTS: Arterial opacification was up to 24% (p < 0.032) higher in protocol B than A, whereas, in the veins it was significantly lower in protocol B than A, with a maximum reduction of up to 84% (p < 0.0001). There was no statistical significance between the central and peripheral pulmonary arteries [>263 Hounsfield units (HU)] in each protocol. Protocol B, demonstrated significant improvement in AVCR at various anatomical sites (p < 0.002). Radiation dose was significantly reduced in protocol B compared to A (p < 0.004). Both ROC and VGC demonstrated significantly higher Az score for protocol B compared to A (p < 0.0001) with an increased inter reader agreement from poor to excellent.

CONCLUSION: Employing a multiphasic CM protocol significantly improves opacification of the thoracic vasculature and visualization of mediastinal lymph nodes during thoracic CT.

ADVANCES IN KNOWLEDGE: Uniform opacification between thoracic arteries and veins increases the delineation between vasculature and lymph nodes, reduces radiation dose when employing a multiphase contrast media injection protocol.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Zein-El-Dine S, Bou Akl I, Mohamad M, et al. Split-bolus contrast injection protocol enhances the visualization of the thoracic vasculature and reduced radiation dose during chest CT. Br J Radiol. 2018. PMID: 30160182. doi:10.1259/bjr.20180509

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。