文献速递头颈神经MR

体素内不相干运动MRI鉴别鼻腔鼻窦小圆细胞恶性肿瘤与非小圆细胞恶性肿瘤:与动态对比增强MRI的比较及相关性研究

Intravoxel incoherent motion MRI for differentiating sinonasal small round cell malignant tumours (SRCMTs) from Non-SRCMTs: comparison and correlation with dynamic contrast-enhanced MRI.
PubMed 文献 · Clin Radiol · 2018-08-04

研究纳入90例经组织学确诊的鼻腔鼻窦恶性肿瘤患者(53例小圆细胞恶性肿瘤,37例非小圆细胞恶性肿瘤),治疗前均行常规MRI、IVIM及DCE-MRI检查。小圆细胞恶性肿瘤的D值低于非小圆细胞恶性肿瘤、D*值高于非小圆细胞恶性肿瘤、Ve值低于非小圆细胞恶性肿瘤;D值诊断效能最佳,以0.56×10-3 mm2/s为截断值,敏感度80.4%、特异度75%、准确率78.2%、AUC 0.825。IVIM与DCE-MRI参数间存在显著但弱至中等程度的相关性。

要点

  • 小圆细胞恶性肿瘤的D值低于非小圆细胞恶性肿瘤(p<0.001),D值诊断效能优于其他灌注及扩散参数。
  • D值截断值0.56×10-3 mm2/s鉴别两类肿瘤的敏感度80.4%、特异度75%、准确率78.2%、AUC 0.825。
  • 小圆细胞恶性肿瘤D*值高于非小圆细胞恶性肿瘤(p=0.011),Ve值低于非小圆细胞恶性肿瘤(p=0.020)。

核心结论

  • IVIM的D值、D*值及DCE-MRI的Ve值有助于鉴别鼻腔鼻窦小圆细胞恶性肿瘤与非小圆细胞恶性肿瘤,其中D值诊断效能最佳。

研究设计与样本

  • 纳入90例经组织学确诊的鼻腔鼻窦恶性肿瘤患者(53例小圆细胞恶性肿瘤,37例非小圆细胞恶性肿瘤),治疗前均行常规MRI、IVIM及DCE-MRI检查。

诊断标准与关键数值

  • D值截断值0.56×10-3 mm2/s鉴别小圆细胞恶性肿瘤与非小圆细胞恶性肿瘤的敏感度80.4%、特异度75%、准确率78.2%、AUC 0.825。

局限性

  • IVIM与DCE-MRI参数间相关性显著但仅为弱至中等程度。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To investigate the value of intravoxel incoherent motion (IVIM) in the differentiation of sinonasal small round cell malignant tumours (SRCMTs) from non-SRCMTs and to compare and correlate these results with those of dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI).

MATERIALS AND METHODS: Ninety patients with histologically confirmed sinonasal malignant tumours (53 SRCMTs and 37 non-SRCMTs) who underwent conventional MRI, IVIM, and DCE-MRI before treatment were enrolled. The IVIM and DCE-MRI parameters were measured. Statistical analyses were performed using Student's t-tests, receiver operating characteristic (ROC) curve analyses, and Spearman's correlation coefficients.

RESULTS: A lower pure diffusion coefficient (D) value and a higher pseudo-diffusion coefficient (D*) value were found in the sinonasal SRCMTs than in the non-SRCMTs (p<0.001 and p=0.011, respectively). Moreover, the mean extravascular extracellular space volume ratio (Ve) of the SRCMTs was significantly lower than that of the non-SRCMTs (p=0.020). ROC curve analysis showed that the diagnostic performance of D outperformed those of the other perfusion and diffusion parameters. A cut-off D value of 0.56 ×10-3 mm2/s yielded a sensitivity of 80.4%, a specificity of 75%, and an accuracy of 78.2%, with an AUC of 0.825. Significant but poor-to-fair correlations were found between the parameters from IVIM and DCE-MRI.

CONCLUSIONS: The D and D* values of IVIM and the Ve value of DCE-MRI are helpful in distinguishing sinonasal SRCMTs from non-SRCMTs, with the D values having the best diagnostic efficiency.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Zhong Y, Xiao Z, Tang Z, et al. Intravoxel incoherent motion MRI for differentiating sinonasal small round cell malignant tumours (SRCMTs) from Non-SRCMTs: comparison and correlation with dynamic contrast-enhanced MRI. Clin Radiol. 2018. PMID: 30086857. doi:10.1016/j.crad.2018.07.097

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。