文献速递头颈技术与安全CT

基于体视学与CT成像的离体眼眶容积测量:与手动平面测量法的比较

Ex vivo orbital volumetry using stereology and CT imaging: A comparison with manual planimetry.
PubMed 文献 · Eur Radiol · 2018-08-22

本研究以羊颅骨CT成像为实验对象,以水填充法作为验证技术,比较体视学与手动平面测量法在眼眶容积测量中的适用性,并在5名人类受试者中评估量化技术。结果显示体视学在用户操作负担和耗时方面优于手动平面测量法,1/8系统抽样方案误差系数低(2.59%)、测量时间短(1.9分钟),且在人类受试者中与手动平面测量法高度相关。

要点

  • 体视学可基于CT测量眼眶容积,1/8系统抽样方案误差系数2.59%、测量时间1.9分钟。
  • 体视学与金标准水填充法高度相关(r=0.893,p=0.001),但配对t检验显示方法间差异有统计学意义(p=0.014)。
  • 手动平面测量法与金标准水填充法高度相关(r=0.957,p≈0.001)且差异无统计学意义(p=0.154)。

核心结论

  • 体视学测量在用户操作负担和耗时方面优于手动平面测量法,1/8系统抽样方案成功应用于人类受试者,并与手动平面测量法高度相关。

研究设计与样本

  • 实验研究,使用羊颅骨进行CT成像,以水填充法作为验证技术,并在5名人类受试者中评估量化技术;检验了观察者内和观察者间一致性。

诊断标准与关键数值

  • 体视学1/8系统抽样方案误差系数低(2.59%),测量时间1.9分钟。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the applicability of stereology and planimetry in orbital volume measurements using computed tomography (CT) and to compare the results between the two measurements.

METHODS: Experimental study using sheep craniums for CT imaging. Water filling measurements were performed, as the validation technique. Quantification techniques were also evaluated in five human subjects. To examine the proportion of agreement among measurements, we tested intra- and inter-observer agreement.

RESULTS: For stereology customization, a 1/8 systematic sampling scheme was considered as optimal; this resulted in a low coefficient of error (2.59 %) and low measurement time (1.9 mins). In sheep craniums, mean volume measured by water displacement, planimetry and stereology was 17.81 ± 0.59 cm3, 17.87 ± 0.68 cm3 and 17.54 ± 0.49 cm3, respectively. Total volumes, obtained by stereology, were highly correlated with the water-filling method (r=0.893; p = 0.001) and a paired t-test showed significant difference between methods (t=3.047; p = 0.014). Planimetry results displayed a high correlation with the water-filling method (r=0.957; p ≈ 0.001) but no statistically significant difference was found (p = 0.154). Mean difference using planimetry and stereology was 0.332 ± 0.322 cm3. In human subjects, using stereology, the estimated volume ranged between 18.57 cm3 and 19.27 cm3, and the mean orbital volume was 19.05 ± 0.50 cm3 with CE=3.75 ± 0.16 %. Mean measure time was 2.1 ± 0.1 mins.

CONCLUSIONS: Stereological measurements were superior to manual planimetry in terms of user effort and time spent. Stereology sampling of 1/8 was successfully applied in human subjects and yielded a strong correlation with manual planimetry.

KEY POINTS: • Stereology can be applied to measure the orbital volume using computed tomography. • Stereological measurements display high correlation with gold standard planimetry and combine low coefficient of error (2.59%) with low measurement time (1.9 min). • Stereology is superior in terms of user effort and time spent.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Bontzos G, Mazonakis M, Papadaki E, et al. Ex vivo orbital volumetry using stereology and CT imaging: A comparison with manual planimetry. Eur Radiol. 2018. PMID: 30135979. doi:10.1007/s00330-018-5691-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。