文献速递神经MRCT

基于高分辨率MR血管壁成像的三维黑血腔内血管造影检测大脑中动脉狭窄的初步研究

3D Black-Blood Luminal Angiography Derived from High-Resolution MR Vessel Wall Imaging in Detecting MCA Stenosis: A Preliminary Study.
PubMed 文献 · AJNR Am J Neuroradiol · 2018-08-23

本研究以62例疑似大脑中动脉粥样硬化患者为对象,以CTA为参考标准,比较了基于三维血管壁成像源图像生成的黑血腔内血管造影、血管壁成像源图像与TOF-MRA检测大脑中动脉狭窄的诊断效能。结果显示黑血腔内血管造影对重度狭窄的敏感度和对闭塞的特异度均显著高于TOF-MRA,且评估狭窄长度的准确度优于血管壁成像源图像,可作为血管壁成像的衍生图像在不增加采集时间的情况下辅助血管壁成像和TOF-MRA。

要点

  • 黑血腔内血管造影对重度狭窄的敏感度为89.3%,显著高于TOF-MRA的64.3%(P = .039)。
  • 黑血腔内血管造影对闭塞的特异度为95.4%,显著高于TOF-MRA的84.6%(P = .039)。
  • 血管壁成像源图像测量的病变长度显著大于CTA和黑血腔内血管造影(P < .001和P = .010)。

核心结论

  • 黑血腔内血管造影在检测大脑中动脉重度狭窄和闭塞方面优于TOF-MRA,在评估狭窄长度方面较血管壁成像源图像更准确;该图像可作为血管壁成像的衍生物,在不增加额外采集时间的情况下作为血管壁成像和TOF-MRA的辅助手段。

研究设计与样本

  • 初步研究,纳入62例疑似大脑中动脉粥样硬化患者,患者接受TOF-MRA、血管壁成像和CTA检查。

关键影像表现/征象

  • 黑血腔内血管造影由血管壁成像源图像采用最小强度投影生成。
  • 黑血腔内血管造影的图像质量在多数患者中可满足诊断。
  • 黑血腔内血管造影评估狭窄程度和长度的观察者内及观察者间一致性均极好。

诊断标准与关键数值

  • 以CTA为参考标准,黑血腔内血管造影检测重度狭窄的敏感度为89.3%,TOF-MRA为64.3%,两者比较P = .039。
  • 以CTA为参考标准,黑血腔内血管造影检测闭塞的特异度为95.4%,TOF-MRA为84.6%,两者比较P = .039。
  • 黑血腔内血管造影在狭窄分级方面与血管壁成像源图像相当。

临床应用与阅片要点

  • 黑血腔内血管造影可由血管壁成像源图像衍生生成,不增加额外采集时间,可作为血管壁成像和TOF-MRA的辅助手段。
  • 在评估大脑中动脉重度狭窄和闭塞时,黑血腔内血管造影的诊断效能优于TOF-MRA。
  • 与血管壁成像源图像相比,黑血腔内血管造影评估狭窄长度更准确。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: 3D high-resolution vessel wall imaging is increasingly used for intracranial arterial diseases. This study compared the diagnostic performance of black-blood luminal angiography derived from 3D vessel wall imaging with source images of vessel wall imaging and TOF-MRA in detecting middle cerebral artery stenosis.

MATERIALS AND METHODS: Sixty-two patients with suspected MCA atherosclerosis underwent TOF-MRA, vessel wall imaging, and CTA. Intracranial black-blood luminal angiography was created from source images of vessel wall imaging using minimum intensity projection. The degree and length of MCA stenosis were measured on source images of vessel wall imaging, TOF-MRA, and black-blood luminal angiography and compared using CTA as a reference standard.

RESULTS: The image quality of black-blood luminal angiography was diagnostic in most patients. The intra- and interobserver agreement for both stenosis degree and length measurements was excellent for black-blood luminal angiography. It was comparable with that of source images of vessel wall imaging in grading stenosis. Compared with TOF-MRA, black-blood luminal angiography showed significantly higher sensitivity for the detection of severe stenosis (89.3% versus 64.3%, P = .039) and higher specificity for the detection of occlusion (95.4% versus 84.6%, P = .039). Lesion length estimated on source images of vessel wall imaging was significantly greater than that measured by CTA and black-blood luminal angiography (P < .001 and P = .010).

CONCLUSIONS: Black-blood luminal angiography is better than TOF-MRA in detecting severe stenosis and occlusion of the MCA. Compared with source images of vessel wall imaging, it is more accurate in evaluating stenosis length. Black-blood luminal angiography can be produced as a derivative from vessel wall imaging and implemented as an adjunct to vessel wall imaging and TOF-MRA without extra acquisition time.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Bai X, Lv P, Liu K, et al. 3D Black-Blood Luminal Angiography Derived from High-Resolution MR Vessel Wall Imaging in Detecting MCA Stenosis: A Preliminary Study. AJNR Am J Neuroradiol. 2018. PMID: 30139751. doi:10.3174/ajnr.A5770

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。