厚层重叠MIP对比增强3D T1加权CUBE图像检测颅内转移瘤的评估:与不重叠CUBE MIP、CUBE及反转恢复准备快速扰相梯度回波脑容积成像在病灶检出、判读时间和敏感度比较的先导研究

Evaluation of Thick-Slab Overlapping MIP Images of Contrast-Enhanced 3D T1-Weighted CUBE for Detection of Intracranial Metastases: A Pilot Study for Comparison of Lesion Detection, Interpretation Time, and Sensitivity with Nonoverlapping CUBE MIP, CUBE, and Inversion-Recovery-Prepared Fast-Spoiled Gradient Recalled Brain Volume.
PubMed 文献 · AJNR Am J Neuroradiol · 2018-08-09

回顾性纳入48例脑转移瘤患者,比较重叠CUBE MIP、不重叠CUBE MIP、CUBE与IR-FSPGR-BRAVO的病灶检出、判读时间及敏感度。各序列检出转移瘤总数无显著差异,CUBE MIP判读时间较CUBE和IR-FSPGR-BRAVO平均至少缩短50秒(P < .001),重叠CUBE MIP与CUBE敏感度最高(0.93-0.97)。作者认为重叠或不重叠CUBE MIP可在不牺牲敏感度的情况下减少判读时间,重叠CUBE MIP病灶对比噪声比最高。

要点

  • CUBE MIP判读时间较CUBE和IR-FSPGR-BRAVO平均至少缩短50秒(P < .001)。
  • 各图像类型检出转移瘤总数无显著差异,重叠CUBE MIP与CUBE敏感度最高(0.93-0.97)。
  • 小病灶(<4 mm)平均对比噪声比不重叠CUBE MIP为1.55,低于重叠CUBE MIP的2.35。

核心结论

  • 本研究提示,使用重叠CUBE MIP或不重叠CUBE MIP检测脑转移瘤可减少判读时间而不牺牲敏感度,其中重叠CUBE MIP的病灶对比噪声比最高。

研究设计与样本

  • 回顾性研究,纳入本院2016年6月至2017年10月48例脑转移瘤患者,脑MRI在多台3T扫描仪上采集,包括钆增强T1加权IR-FSPGR-BRAVO和CUBE,并生成不重叠CUBE MIP和重叠CUBE MIP;两名盲法放射科医师识别各图像类型上转移瘤的总数和位置,采用Cohen κ评估阅片者间一致性,评估敏感度、判读时间和病灶对比噪声比。

关键影像表现/征象

  • 所有图像类型识别转移瘤的阅片者间一致性为一般至中等(κ = 0.222-0.598)。
  • 各图像类型检出的转移瘤总数无显著差异。
  • CUBE MIP判读时间显著短于CUBE和IR-FSPGR-BRAVO,平均每例至少节省50秒(P < .001)。
  • 两种CUBE MIP的平均病灶对比噪声比均高于IR-FSPGR-BRAVO。
  • 小病灶(<4 mm)平均对比噪声比不重叠CUBE MIP为1.55,低于重叠CUBE MIP的2.35。

诊断标准与关键数值

  • 两名阅片者各图像类型病灶检出敏感度均高,重叠CUBE MIP与CUBE最高(0.93-0.97)。
  • 阅片者间一致性Cohen κ = 0.222-0.598。

临床应用与阅片要点

  • 作者认为重叠CUBE MIP或不重叠CUBE MIP可用于脑转移瘤检测,能减少判读时间而不牺牲敏感度。
  • 重叠CUBE MIP的病灶对比噪声比最高,小病灶(<4 mm)平均对比噪声比不重叠CUBE MIP为1.55、重叠CUBE MIP为2.35。

局限性

  • 原文未报告局限性(原文结论仅称本研究为先导研究,未列出具体局限)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Early and accurate identification of cerebral metastases is important for prognostication and treatment planning although this process is often time consuming and labor intensive, especially with the hundreds of images associated with 3D volumetric imaging. This study aimed to evaluate the benefits of thick-slab overlapping MIPs constructed from contrast-enhanced T1-weighted CUBE (overlapping CUBE MIP) for the detection of brain metastases in comparison with traditional CUBE and inversion-recovery prepared fast-spoiled gradient recalled brain volume (IR-FSPGR-BRAVO) and nonoverlapping CUBE MIP.

MATERIALS AND METHODS: A retrospective review of 48 patients with cerebral metastases was performed at our institution from June 2016 to October 2017. Brain MRIs, which were acquired on multiple 3T scanners, included gadolinium-enhanced T1-weighted IR-FSPGR-BRAVO and CUBE, with subsequent generation of nonoverlapping CUBE MIP and overlapping CUBE MIP. Two blinded radiologists identified the total number and location of metastases on each image type. The Cohen κ was used to determine interrater agreement. Sensitivity, interpretation time, and lesion contrast-to-noise ratio were assessed.

RESULTS: Interrater agreement for identification of metastases was fair-to-moderate for all image types (κ = 0.222-0.598). The total number of metastases identified was not significantly different across the image types. Interpretation time for CUBE MIPs was significantly shorter than for CUBE and IR-FSPGR-BRAVO, saving at least 50 seconds per case on average (P < .001). The mean lesion contrast-to-noise ratio for both CUBE MIPs was higher than for IR-FSPGR-BRAVO. The mean contrast-to-noise ratio for small lesions (<4 mm) was lower for nonoverlapping CUBE MIP (1.55) than for overlapping CUBE MIP (2.35). For both readers, the sensitivity for lesion detection was high for all image types but highest for overlapping CUBE MIP and CUBE (0.93-0.97).

CONCLUSIONS: This study suggests that the use of overlapping CUBE MIP or nonoverlapping CUBE MIP for the detection of brain metastases can reduce interpretation time without sacrificing sensitivity, though the contrast-to-noise ratio of lesions is highest for overlapping CUBE MIP.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Yoon BC, Saad AF, Rezaii P, et al. Evaluation of Thick-Slab Overlapping MIP Images of Contrast-Enhanced 3D T1-Weighted CUBE for Detection of Intracranial Metastases: A Pilot Study for Comparison of Lesion Detection, Interpretation Time, and Sensitivity with Nonoverlapping CUBE MIP, CUBE, and Inversion-Recovery-Prepared Fast-Spoiled Gradient Recalled Brain Volume. AJNR Am J Neuroradiol. 2018. PMID: 30093483. doi:10.3174/ajnr.A5747