文献速递神经MR

基于术前术后MRI图像的支持向量机分类器鉴别高级别胶质瘤患者血管源性水肿与非强化肿瘤

On differentiation between vasogenic edema and non-enhancing tumor in high-grade glioma patients using a support vector machine classifier based upon pre and post-surgery MRI images.
PubMed 文献 · Eur J Radiol · 2018-07-20

本研究纳入9例高级别胶质瘤患者的术前术后MRI及9例转移瘤患者术前MRI,以术后非强化FLAIR高信号区(经组织学验证主要为肿瘤组织)作为非强化肿瘤的替代参考标准,以转移瘤非强化FLAIR高信号区作为血管源性水肿,利用DCE-MRI的T1灌注参数构建SVM分类器鉴别两者,ROC分析显示邻域平滑后误分类误差由8.4%降至2.4%。

要点

  • 术后非强化FLAIR高信号区经组织学验证主要为肿瘤组织,可作为非强化肿瘤的替代参考标准。
  • SVM分类器鉴别非强化肿瘤与血管源性水肿的误分类误差为8.4%,邻域平滑后降至2.4%。
  • 仅凭T2-W/FLAIR高信号难以区分血管源性水肿与非强化肿瘤,需结合T1灌注MRI参数。

核心结论

  • 本研究提出一种基于SVM分类器的半自动分割方法,用于鉴别高级别胶质瘤患者的非强化肿瘤与血管源性水肿,该分类器以独立于放射科医生手动勾画的替代参考标准进行训练。

研究设计与样本

  • 研究纳入9例高级别胶质瘤患者(含术前和术后MRI数据)和9例转移瘤患者(含术前MRI数据),MRI序列包括常规T1-W、T2-W、FLAIR及DCE-MRI动态图像,以术后非强化FLAIR高信号区作为非强化肿瘤的替代参考标准并经组织学验证,以转移瘤非强化FLAIR高信号区作为血管源性水肿,采用SVM分类并进行ROC分析,输出经邻域平滑后处理。

关键影像表现/征象

  • 高级别胶质瘤和转移瘤的非强化FLAIR高信号区在T2-W/FLAIR图像上均表现为高信号,肉眼难以区分血管源性水肿与非强化肿瘤。
  • 组织学检查显示切除组织主要由肿瘤组织构成,水肿占7.21 ± 4.05%,并含少量健康组织。

诊断标准与关键数值

  • SVM分类器鉴别非强化肿瘤与血管源性水肿的误分类误差为8.4%。
  • 经邻域平滑后处理,SVM分类器的误分类误差降至2.4%。

临床应用与阅片要点

  • 作者认为,所提出的方法可能成为胶质瘤患者术前和术后评估的有用工具。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: High grade gliomas (HGGs) are infiltrative in nature. Differentiation between vasogenic edema and non-contrast enhancing tumor is difficult as both appear hyperintense in T2-W/FLAIR images. Most studies involving differentiation between vasogenic edema and non-enhancing tumor consider radiologist-based tumor delineation as the ground truth. However, analysis by a radiologist can be subjective and there remain both inter- and intra-rater differences. The objective of the current study is to develop a methodology for differentiation between non-enhancing tumor and vasogenic edema in HGG patients based on T1 perfusion MRI parameters, using a ground truth which is independent of a radiologist's manual delineation of the tumor.

MATERIAL AND METHODS: This study included 9 HGG patients with pre- and post-surgery MRI data and 9 metastasis patients with pre-surgery MRI data. MRI data included conventional T1-W, T2-W, and FLAIR images and DCE-MRI dynamic images. In this study, the authors hypothesize that surgeried non-enhancing FLAIR hyperintense tissue, which was obtained using pre- and post-surgery MRI images of glioma patients, should be largely comprised of non-enhancing tumor. Hence this could be used as an alternative ground truth for the non-enhancing tumor region. Histological examination of the resected tissue was done for validation. Vasogenic edema was obtained from the non-enhancing FLAIR hyperintense region of metastasis patients, as they have a clear boundary between enhancing tumor and edema. DCE-MRI data analysis was performed to obtain T1 perfusion MRI parameters. Support Vector Machine (SVM) classification was performed using T1 perfusion MRI parameters to differentiate between non-enhancing tumor and vasogenic edema. Receiver-operating-characteristic (ROC) analysis was done on the results of the SVM classifier. For improved classification accuracy, the SVM output was post-processed via neighborhood smoothing.

RESULTS: Histology results showed that resected tissue consists largely of tumorous tissue with 7.21 ± 4.05% edema and a small amount of healthy tissue. SVM-based classification provided a misclassification error of 8.4% in differentiation between non-enhancing tumor and vasogenic edema, which was further reduced to 2.4% using neighborhood smoothing.

CONCLUSION: The current study proposes a semiautomatic method for segmentation between non-enhancing tumor and vasogenic edema in HGG patients, based on an SVM classifier trained on an alternative ground truth to a radiologist's manual delineation of a tumor. The proposed methodology may prove to be a useful tool for pre- and post-operative evaluation of glioma patients.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Sengupta A, Agarwal S, Gupta PK, et al. On differentiation between vasogenic edema and non-enhancing tumor in high-grade glioma patients using a support vector machine classifier based upon pre and post-surgery MRI images. Eur J Radiol. 2018. PMID: 30150045. doi:10.1016/j.ejrad.2018.07.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。