3T黑血T1加权颅内血管壁成像显示豆纹动脉:与7T TOF-MRA比较
本研究在13名健康志愿者中于同一天行3T颅内T1加权血管壁成像(VWI)和7T TOF-MRA,比较两者显示豆纹动脉(LSA)主干、分支数目及影像质量;另纳入9例颅内动脉狭窄卒中患者,比较症状侧与无症状侧LSA分支。结果表明3T VWI能显示LSA,尤其主干和近段,影像质量与7T TOF-MRA相当。
要点
- 3T VWI可显示豆纹动脉主干及近段,影像质量与7T TOF-MRA相当。
- 3T VWI显示的分支数略低于7T TOF,但局部长度(距大脑中动脉5-15 mm)高度一致(ICC=0.970)。
- 一次3T VWI扫描可同时评估大血管壁病变和豆纹动脉血管病变。
核心结论
- 3T VWI能够显示豆纹动脉,尤其是主干和近段,影像质量与7T TOF-MRA相当。
研究设计与样本
- 13名健康志愿者在同一天接受3T VWI和7T TOF-MRA检查;另纳入9例颅内动脉狭窄卒中患者,比较症状侧与无症状侧LSA分支。
关键影像表现/征象
- 7T TOF-MRA与3T VWI提取的血管树一致性良好。
- 3T VWI显示的分支数略低于7T TOF。
- 卒中患者大脑中动脉节段共识别12个斑块,其中9个位于症状侧。
- 3T VWI显示的症状侧LSA平均数目为4.3±1.3,无症状侧为5.0±1.1。
诊断标准与关键数值
- 7T TOF-MRA与3T VWI显示LSA主干数目相似。
- 3T VWI测得LSA全长略低于7T TOF(p=0.011,ICC=0.917)。
- 距大脑中动脉5-15 mm的局部长度在VWI与TOF-MRA之间高度一致(p=0.098,ICC=0.970)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The objective of this study was to explore the feasibility of using intracranial T1-weighted vessel wall imaging (VWI) to visualize the lenticulostriate arteries (LSAs) at 3T.
MATERIAL AND METHODS: Thirteen healthy volunteers were examined with VWI at 3T and TOF-MRA at 7T during the same day. On the vascular skeletons obtained by manual tracing, the number of stems and branches of LSAs were counted. On the most prominent branch in every hemisphere, the contrast-to-noise ratio (CNR), the full length and the local length (5-15 mm above MCAs) were measured and compared between the two methods. Nine stroke patients with intracranial artery stenosis were also recruited into the study. The branches of LSAs were compared between the symptomatic and asymptomatic side.
RESULTS: The extracted vascular trees were in good agreement between 7T TOF-MRA and 3T VWI. The two acquisitions showed similar numbers of the LSA stems. The number of branches revealed by 3T VWI was slightly lower than 7T TOF. The full lengths were slightly lower by VWI at 3T (p = 0.011, ICC = 0.917). The measured local lengths (5-15 mm from MCAs) showed high coherence between VWI and TOF-MRA (p = 0.098, ICC = 0.970). In stroke patients, 12 plaques were identified on MCA segments, and nine plaques were located on the symptomatic side. The average numbers of LSA visualized by 3T VWI were 4.3±1.3 on the symptomatic side and 5.0±1.1 on the asymptomatic side.
CONCLUSION: 3T VWI is capable of depicting LSAs, particularly the stems and the proximal segments, with comparable image quality to that of 7T TOF-MRA.
KEY POINTS: • T1-weighted intracranial VWI at 3T allows for black-blood MR angiography of lenticulostriate artery. • 3T intracranial VWI depicts the stems and proximal segments of the lenticulostriate arteries comparable to 7T TOF-MRA. • It is feasible to assess both large vessel wall lesions and lenticulostriate vasculopathy in one scan.
引用
- Zhang Z, Fan Z, Kong Q, et al. Visualization of the lenticulostriate arteries at 3T using black-blood T1-weighted intracranial vessel wall imaging: comparison with 7T TOF-MRA. Eur Radiol. 2018. PMID: 30151642. doi:10.1007/s00330-018-5701-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。