PubMed 文献 · Eur Radiol · 2018-08-07

回顾性分析20例大脑中动脉梗死患者,比较Gd增强3D T1W黑血FSE与T2-FLAIR上高信号动脉的对比噪声比及一致性。Gd增强序列对比更高(2.27±1.65 vs 0.94±0.86,p=0.01),两序列一致性极好(ρ=0.76,p<0.01);高信号动脉评分较高组灌注缺损大于评分较低组(196.7±41.4 vs 100.1±130.1,p=0.03)。

要点

  • Gd增强3D T1W黑血FSE上高信号动脉可能代表缓慢的侧支血流。
  • 该序列高信号动脉与T2-FLAIR高信号血管影匹配良好,且对比度更高。
  • 高信号动脉分布范围较广的患者灌注缺损大于范围较窄者。

核心结论

  • 急性大脑中动脉卒中患者Gd增强3D T1W黑血FSE上的高信号动脉可能代表缓慢的侧支血流,其分布区域与FLAIR高信号血管影对应但对比更好,且高信号动脉范围较广者灌注缺损更大。

研究设计与样本

  • 回顾性分析20例大脑中动脉梗死患者,测量高信号动脉与邻近灰质的对比噪声比,比较Gd增强3D T1W黑血FSE与T2-FLAIR,并用组内相关系数评估两序列高信号动脉的一致性;按高信号动脉评分将队列二分为两组比较临床数据。

关键影像表现/征象

  • Gd增强3D T1W黑血FSE上高信号动脉与灰质的对比度显著高于T2-FLAIR(2.27±1.65 vs 0.94±0.86,p=0.01)。
  • T2-FLAIR与Gd增强3D T1W黑血FSE上高信号动脉的一致性极好(ρ=0.76,p<0.01)。
  • 高信号动脉评分较高的患者灌注缺损大于评分较低者(196.7±41.4 vs 100.1±130.1,p=0.03)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To elucidate the pathogenesis of hyperintense arteries on Gd-enhanced 3D T1W BB FSE and their clinical significance in acute middle cerebral artery (MCA) stroke.

METHODS: We retrospectively reviewed 20 patients with MCA infarction. We measured the contrast-to-noise ratio between hyperintense artery and adjacent grey matter on T2-FLAIR and Gd-enhanced 3D T1W BB FSE and compared them by using Student's t test. The agreement of positive hyperintense artery between T2 FLAIR and Gd-enhanced 3D T1WI BB FSE was estimated with intraclass correlation coefficient. Our cohort was dichotomised into two groups depending on hyperintense artery scores, and clinical data were compared between two groups by using Student's t test and chi-square test.

RESULTS: The contrast between hyperintense artery and grey matter on Gd-enhanced 3D T1W BB FSE was significantly higher than that on T2-FLAIR (2.27 ± 1.65 versus 0.94 ± 0.86, p = 0.01). Overall, agreement of hyperintense arteries on T2-FLAIR and Gd-enhanced 3D T1W BB FSE was excellent (ρ = 0.76, p < 0.01). Patients with higher hyperintense artery scores had higher perfusion deficits that those with lower hyperintense artery scores (196.7 ± 41.4 vs 100.1 ± 130.1, p = 0.03).

CONCLUSION: Hyperintense arteries on Gd-enhanced 3D T1W BB FSE in acute MCA stroke may be associated with slow collateral flows. Their territories corresponded to those of FLAIR, but had a better contrast. The patients with hyperintense arteries in a wider territory showed larger perfusion deficit than those with hyperintense arteries in a narrower territory.

KEY POINTS: • Hyperintense arteries on Gd-enhanced 3D T1W BB FSE are slow collateral flows. • Hyperintense arteries on Gd-enhanced 3D T1W BB FSE are well matched with FLAIR hyperintense vessels. • Hyperintense arteries are associated with perfusion deficit in stroke patients.