对比增强MRA与时间飞跃法MRA在急性缺血性卒中MRI中的价值
该回顾性研究纳入123例大血管闭塞急性缺血性卒中患者,于血栓切除术前行3T MR成像,比较TOF-MRA与对比增强MRA识别血管闭塞及侧支循环状态的诊断准确性,以DSA为参考标准。结果显示对比增强MRA在闭塞定位、侧支评估及采集时间与覆盖范围方面均优于TOF-MRA,支持将对比增强MRA纳入急性卒中MR成像方案。
要点
- 对比增强MRA闭塞定位与DSA无显著差异(P=.75),TOF-MRA与DSA差异显著(P<.001)。
- 对比增强MRA与DSA侧支评估一致率94.9%(P=.25),TOF-MRA仅23.2%(P<.001)。
- 对比增强MRA采集时间更短、覆盖范围更大(含颅外血管),诊断准确性优于TOF-MRA。
核心结论
- 对比增强MRA在急性缺血性卒中中诊断准确性优于TOF-MRA,闭塞定位与侧支评估更准确,支持将对比增强MRA纳入急性卒中MR成像。
研究设计与样本
- 回顾性研究纳入123例血栓切除术前大血管闭塞卒中患者,术前行3T MR成像(颅内动脉常规3D TOF-MRA及颅内、外动脉对比增强MRA),由2名神经放射科医生独立评估,以DSA为参考标准。
诊断标准与关键数值
- TOF-MRA与对比增强MRA的观察者间一致性分别为κ=0.74(95%CI 0.66-0.83)和κ=0.72(95%CI 0.63-0.80)。
- TOF-MRA与DSA闭塞定位差异显著(P<.001),对比增强MRA与DSA无显著差异(P=.75)。
- 对比增强MRA与DSA侧支评估一致率94.9%(P=.25),TOF-MRA与DSA一致率23.2%(P<.001)。
临床应用与阅片要点
- 作者结论支持将对比增强MRA纳入急性卒中MR成像,可能使TOF-MRA变为多余。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Vessel imaging in acute ischemic stroke is essential to select patients with large-vessel occlusion for mechanical thrombectomy. Our aim was to compare the diagnostic accuracy of time-of-flight MR angiography and contrast-enhanced MR angiography for identification of vessel occlusion and collateral status in acute ischemic stroke.
MATERIALS AND METHODS: One hundred twenty-three patients with stroke with large-vessel occlusion before thrombectomy were included in this retrospective study. Before thrombectomy, 3T MR imaging, including conventional 3D TOF-MRA of the intracranial arteries and contrast-enhanced MRA of intra- and extracranial arteries, was performed. Both techniques were assessed independently by 2 neuroradiologists for location of the occlusion, imaging quality, and collateral status. Findings were compared, with subsequent DSA as the reference standard.
RESULTS: Both techniques had good interrater agreement of κ = 0.74 (95% CI, 0.66-0.83) for TOF-MRA and κ = 0.72 (95% CI, 0.63-0.80) for contrast-enhanced MRA. Occlusion localization differed significantly on TOF-MRA compared with DSA (P < .001), while no significant difference was observed between DSA and contrast-enhanced MRA (P = .75). Assessment of collaterals showed very good agreement between contrast-enhanced MRA and DSA (94.9% with P = .25), but only fair agreement between TOF-MRA and DSA (23.2% with P < .001).
CONCLUSIONS: Contrast-enhanced MRA offers better diagnostic accuracy than TOF-MRA in acute ischemic stroke. Contrast-enhanced MRA was superior in localizing vessel occlusion within a shorter acquisition time while providing a larger coverage, including extracranial vessels, and a more accurate assessment of collateral status. These results support inclusion of contrast-enhanced MRA in acute stroke MR imaging, perhaps making TOF-MRA superfluous.
引用
- Boujan T, Neuberger U, Pfaff J, et al. Value of Contrast-Enhanced MRA versus Time-of-Flight MRA in Acute Ischemic Stroke MRI. AJNR Am J Neuroradiol. 2018. PMID: 30115678. doi:10.3174/ajnr.A5771
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。