特发性颅内高压视盘的弥散张量成像研究
前瞻性研究纳入31例特发性颅内高压患者和17例年龄性别匹配对照,行视神经弥散张量成像,由两名阅片者测量视盘各向异性分数(FA)和平均弥散率(MD)。患者视盘FA显著低于对照(p=0.001),MD显著高于对照(p=0.001),FA和MD鉴别诊断的AUC分别为0.921/0.914和0.943/0.922。视盘FA在早期视乳头水肿和视野缺损中显著低于晚期,MD显著高于晚期。
要点
- 视盘FA在特发性颅内高压患者中显著低于对照(p=0.001),MD显著高于对照(p=0.001)。
- FA鉴别诊断界值0.28和0.29,AUC 0.921和0.914,准确率92%和91%,敏感度97%和96%。
- MD鉴别诊断界值1.51和1.22×10-3 mm2/s,AUC 0.943和0.922,准确率94%和92%。
核心结论
- 视盘弥散张量成像参数是无创可靠的影像指标,可用于特发性颅内高压的诊断,并与视乳头水肿和视野缺损相关。
研究设计与样本
- 前瞻性研究纳入31例连续特发性颅内高压患者和17例年龄性别匹配对照,行视神经弥散张量成像,由两名阅片者测量视盘FA和MD,视乳头水肿分级和视野缺损由眼科医生评估。
关键影像表现/征象
- 特发性颅内高压患者视盘FA显著低于对照(p=0.001),两名阅片者间一致性极好(K=0.93)。
- 特发性颅内高压患者视盘MD显著高于对照(p=0.001),两名阅片者间一致性极好(K=0.91)。
- 视盘FA在早期视乳头水肿中显著低于晚期(p=0.001),在早期视野缺损中显著低于晚期(p=0.001)。
- 视盘MD在早期视乳头水肿中显著高于晚期(p=0.001),在早期视野缺损中显著高于晚期(p=0.001)。
诊断标准与关键数值
- FA鉴别特发性颅内高压与对照的界值为0.28和0.29(两名阅片者),AUC分别为0.921和0.914,准确率92%和91%,敏感度97%和96%。
- MD鉴别特发性颅内高压与对照的界值为1.51和1.22×10-3 mm2/s(两名阅片者),AUC分别为0.943和0.922,准确率94%和92%。
临床应用与阅片要点
- 视盘弥散张量成像参数可作为特发性颅内高压的无创诊断辅助指标,阅片时需关注视盘FA降低和MD升高。
- 视盘FA和MD与视乳头水肿及视野缺损的早晚分期相关,早期FA更低、MD更高。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To study optic disc in idiopathic intracranial hypertension (IIH) with diffusion tensor imaging.
METHODS: Prospective study was carried out on 31 consecutive patients with IIH and 17 age and sex-matched controls that underwent diffusion tensor imaging of optic nerve. Fractional anisotropy (FA) and mean diffusivity (MD) of optic disc were measured by two readers. Grades of papilledema and visual field defects were evaluated by ophthalmologist.
RESULTS: FA of optic disc was significantly lower in IIH than controls (p = 0.001) with excellent inter-observer agreement (K = 0.93) of both readers. The cutoff FA used to differentiating IIH from controls were 0.28 and 0.29 with area under curve (AUC) of 0.921 and 0.914, accuracy 92% and 91%, and sensitivity 97% and 96%. MD of optic disc were significantly higher in IIH than in controls (p = 0.001) with excellent inter-observer agreement (K = 0.91) of both readers. The cutoff MD used to differentiating IIH from controls was 1.51 and 1.22 × 10-3 mm2/s with AUC 0.943 and 0.922, and accuracy 94% and 92% respectively. FA of optic disc was significantly lower in early than advanced papilledema and visual field defects (p = 0.001, 0.001) respectively. The MD of optic disc was significantly higher in early than advanced papilledema and visual field defects (p = 0.001, 0.001) respectively.
CONCLUSION: Diffusion tensor imaging parameters of optic disc are non-invasive reliable imaging parameters that can be used for diagnosis of IIH and well correlated with papilledema and visual field defects.
引用
- Razek AAKA, Batouty N, Fathy W, et al. Diffusion tensor imaging of the optic disc in idiopathic intracranial hypertension. Neuroradiology. 2018. PMID: 30136119. doi:10.1007/s00234-018-2078-1