指南与共识骨肌US

脊柱关节炎与银屑病关节炎附着点炎共识超声定义及评分的信度:一项OMERACT超声研究

Reliability of a consensus-based ultrasound definition and scoring for enthesitis in spondyloarthritis and psoriatic arthritis: an OMERACT US initiative.
指南 / 共识 · Ann Rheum Dis · 2018-08-03

本研究评估OMERACT共识超声定义附着点炎各基本成分的信度,11名超声医师对5例脊柱关节炎/银屑病关节炎患者的40个附着点进行评分,九项病变中附着点骨赘(55%)和骨不规则(54%)最常见,校正低患病率后附着点插入处多普勒信号(kappa 0.9)和滑囊炎(kappa 0.8)信度最佳,最终定义纳入低回声、附着点增厚、骨侵蚀、钙化/骨赘及插入处多普勒信号。

要点

  • 附着点炎超声基本病变包括低回声、增厚、骨赘、钙化、骨侵蚀、骨不规则、滑囊炎及插入处/周围多普勒信号。
  • 校正低患病率后,插入处多普勒信号(kappa 0.9)和滑囊炎(kappa 0.8)信度最佳。
  • 最终共识定义纳入低回声、附着点增厚、骨侵蚀、钙化/骨赘及插入处多普勒信号。

核心结论

  • 通过共识逐步法,产生了可靠的脊柱关节炎/银屑病关节炎附着点炎超声评分和定义,需进一步研究以在临床试验和实践中实施该评分。

研究设计与样本

  • 信度研究,11名超声医师评估5例脊柱关节炎/银屑病关节炎患者的40个附着点(四个双侧部位),对九项超声基本病变进行二分类评分,采用kappa统计评估信度,并以至少75%的附着点中被评为存在的病变纳入最终定义。

关键影像表现/征象

  • 除骨赘(55%)和骨不规则(54%)外,检出病变的患病率相当低。
  • 信度从差到好不等,最低为附着点增厚(kappa 0.1,95%CI 0至0.7),最高为骨赘(kappa 0.6,95%CI 0.5至0.7)。
  • 校正低患病率后,所有病变的kappa值均增加,最佳为插入处多普勒信号(0.9)和滑囊炎(0.8)。

诊断标准与关键数值

  • 最终定义纳入的超声成分为低回声、附着点厚度增加、骨侵蚀、钙化/骨赘及插入处多普勒信号。
  • 仅将在至少75%的被认为有附着点炎的附着点中评为存在的病变纳入最终定义。

临床应用与阅片要点

  • 超声医师在评估附着点炎时,应关注低回声、附着点增厚、骨侵蚀、钙化/骨赘及插入处多普勒信号这些共识定义成分。
  • 插入处多普勒信号和滑囊炎在低患病率条件下信度较好,可作为报告重点。
  • 原文结论指出需进一步研究以在临床试验和实践中实施该评分。

局限性

  • 原文结论指出需进一步研究以在临床试验和实践中实施该评分。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the reliability of consensus-based ultrasound (US) definitions of elementary components of enthesitis in spondyloarthritis (SpA) and psoriatic arthritis (PsA) and to evaluate which of them had the highest contribution to defining and scoring enthesitis.

METHODS: Eleven sonographers evaluated 40 entheses from five patients with SpA/PsA at four bilateral sites. Nine US elementary lesions were binary-scored: hypoechogenicity, thickened insertion, enthesophytes, calcifications, erosions, bone irregularities, bursitis and Doppler signal inside and around enthesis. Kappa statistics were used to evaluate reliability. Sonographers were also asked to state which lesions can be considered as inflammatory or structural and should be included in the final definition of enthesitis. Only the lesions, scored as present in at least 75% of the entheses considered as having an enthesitis, were included in the final definition.

RESULTS: The prevalence of detected lesions was quite low except for enthesophytes (55%) and bone irregularities (54%). Reliability ranged from poor to good (the lowest for thickened enthesis (kappa 0.1 (95% CI 0 to 0.7)) and the highest for enthesophytes (kappa 0.6 (95% CI 0.5 to 0.7)). When adjusted for low prevalence, kappa values increased for all lesions, with the best result observed for detecting Doppler signal at insertion (0.9) and for bursitis (0.8). The US components included in the final definition were hypoechogenicity, increased thickness at enthesis, erosions and calcifications/enthesophytes and Doppler signal at insertion.

CONCLUSION: By using a consensus-based stepwise approach, a final reliable US score and definition of enthesitis in SpA/PsA were produced. Further studies are sought for implementing this score in clinical trials and practice.

来源:Ann Rheum Dis,查看原文。版权归原作者所有。

引用

  1. Balint PV, Terslev L, Aegerter P, et al. Reliability of a consensus-based ultrasound definition and scoring for enthesitis in spondyloarthritis and psoriatic arthritis: an OMERACT US initiative. Ann Rheum Dis. 2018. PMID: 30076154. doi:10.1136/annrheumdis-2018-213609

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。