文献速递泌尿生殖腹部CT

双源单能MDCT尿路造影中全剂量与半剂量图像重建的滤过反投影与正弦图确认迭代重建比较

Comparison of Full- and Half-Dose Image Reconstruction With Filtered Back Projection or Sinogram-Affirmed Iterative Reconstruction in Dual-Source Single-Energy MDCT Urography.
PubMed 文献 · AJR Am J Roentgenol · 2018-07-24

前瞻性随机研究纳入150例高尿路上皮癌风险患者,行双源单能CT尿路造影,分别以100%、50%、25%辐射剂量重建FBP和SAFIRE图像,7名放射科医师评估1200组数据集。结果显示50%剂量下FBP与SAFIRE的图像质量和病灶置信度均非劣于100%剂量FBP,而25%剂量SAFIRE则劣于100%剂量FBP。

要点

  • 50%辐射剂量下FBP或SAFIRE重建的图像质量与病灶置信度均非劣于100%剂量FBP。
  • 25%辐射剂量SAFIRE重建的图像质量显著低于100%剂量FBP。
  • 病灶存在置信度AUC在FBP 100%剂量为0.907、50%剂量为0.894;SAFIRE 50%剂量为0.900、25%剂量为0.799。

核心结论

  • 无论放射科医师经验如何,50%辐射剂量下FBP和SAFIRE重建的CT尿路造影图像在图像质量和病灶存在置信度方面非劣于100%剂量FBP,而25%剂量SAFIRE则劣于100%剂量FBP。

研究设计与样本

  • 前瞻性随机研究,150例高尿路上皮癌风险患者,使用双源单能扫描仪行CT尿路造影,调整每管辐射输出后以FBP和SAFIRE重建三个辐射剂量水平的数据集,7名放射科医师主观评估共1200组数据集的图像质量和病灶存在置信度,采用非参数聚类数据方法基于0.05非劣效界值估计AUC值。

诊断标准与关键数值

  • 图像质量方面,25%辐射剂量SAFIRE的平均AUC值显著低于100%辐射剂量FBP(所有p < 0.05);病灶存在置信度平均AUC值:FBP 100%剂量为0.907、50%剂量为0.894,SAFIRE 50%剂量为0.900、25%剂量为0.799;非劣效界值为0.05。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The purpose of this study is to prospectively compare the image quality of and confidence in the presence of a lesion on CT urography images acquired using filtered back projection (FBP) with 100% and 50% radiation doses with those for images simultaneously acquired using sinogram-affirmed iterative reconstruction with strength 3 (SAFIRE) with 50% and 25% radiation doses for patients with a high risk for urothelial carcinomas.

SUBJECTS AND METHODS: A total of 150 patients randomly underwent CT urography examinations performed using a dual-source single-energy scanner. After the radiation output of each tube was adjusted, datasets at three radiation dose levels were reconstructed using FBP and SAFIRE. Seven radiologists subjectively assessed image quality and confidence in the presence of a lesion for a total of 1200 datasets. Nonparametric methods for cluster data were used to estimate AUC values for variance methods on the basis of a noninferiority margin of 0.05.

RESULTS: The mean AUC value for image quality in SAFIRE with a 25% radiation dose was significantly lower than that of FBP with 100% radiation dose (p < 0.05 for all). The mean AUC values for the presence of a lesion were 0.907 and 0.894 for FBP, respectively, at 100% and 50% radiation doses, respectively, and 0.900 and 0.799 for SAFIRE at 50% and 25% radiation doses, respectively. However, the image quality of images acquired with SAFIRE at a 25% radiation dose was significantly inferior to that of images acquired with FBP at a 100% radiation dose.

CONCLUSION: Regardless of the experience of the radiologist, CT urography images acquired with FBP and SAFIRE with a 50% radiation dose were noninferior to those acquired with FBP with a 100% radiation dose in terms of image quality and confidence in the presence of a lesion, whereas those acquired with SAFIRE with 25% radiation dose were inferior.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。