利用信息学方法促进可回收下腔静脉滤器患者的临床管理
研究开发半自动滤器追踪应用,从放射信息系统提取下腔静脉滤器置入数据并建立网络界面促进介入放射团队与转诊医师沟通。采用回顾性观察队列方法,比较2016年7-12月与2015年同期6个月的滤器回收率,总体回收率从对照期23%升至试验期34%,滤器置入至回收平均时间无显著差异。
要点
- 半自动滤器追踪系统可促进可回收下腔静脉滤器患者的 care coordination 与临床决策。
- 试验期滤器回收率为34%,高于对照期23%。
- 两期滤器置入至回收平均时间无显著差异(88.9天 vs 102.7天,p=0.32)。
核心结论
- 半自动追踪下腔静脉滤器患者的方法可促进已知有潜在并发症器械的 care coordination 与临床决策,类似应用可复制推广。
研究设计与样本
- 回顾性观察队列研究,比较2016年7-12月试验期与2015年同期6个月对照期的滤器回收率;系统开发约100小时,共追踪293例滤器置入和83例滤器回收。
诊断标准与关键数值
- 总体滤器回收率:对照期23%,试验期34%。
- 滤器置入至回收平均时间:对照期88.9天 vs 试验期102.7天,差异无统计学意义(p=0.32)。
临床应用与阅片要点
- 系统通过查询放射信息系统提取滤器置入关键数据并存入数据库。
- 网络界面展示关键信息并促进介入放射临床团队与转诊医师沟通。
- 根据每例患者临床情况提供一套滤器管理选项。
- 系统开发约需100小时开发时间。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Long indwelling times for inferior vena cava (IVC) filters that are used to prevent venous thromboembolism can result in complications. To improve care for patients receiving retrievable IVC filters, we developed and evaluated an informatics-based initiative to facilitate patient tracking, clinical decision-making, and care coordination.
MATERIALS AND METHODS: A semiautomated filter-tracking application was custom-built to query our radiology information system to extract and transfer key data elements related to IVC filter insertion procedures into a database. A web-based interface displayed key information and facilitated communication between the interventional radiology clinical team and referring physicians. A set of filter management options was provided depending on each patient's clinical condition. The system was launched in April 2016. Using retrospective observational cohort methods, we compared filter retrieval rates during a test period from July through December 2016 with a control period of the same 6 months in 2015.
RESULTS: System development required approximately 100 hours of development time. Two hundred ninety-three IVC filter placements and 83 filter retrievals were tracked during the study periods. The overall filter retrieval rate was 23% in the control period and 34% in the test period. Mean times from filter placement to retrieval in the control and test periods were not significantly different (88.9 and 102.7 days, respectively; p = 0.32).
CONCLUSION: A semiautomated approach to tracking patients with IVC filters can facilitate care coordination and clinical decision-making for a device with known potential complications. Similar applications designed to improve provider communication and documentation of filter management plans, including appropriateness for retrieval, can be replicated.
引用
- Juluru K, Elnajjar P, Shih HH, et al. An Informatics Approach to Facilitate Clinical Management of Patients With Retrievable Inferior Vena Cava Filters. AJR Am J Roentgenol. 2018. PMID: 29975114. doi:10.2214/AJR.18.19561
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。