颈动脉支架置入术中血管内超声检测支架内突出(ISP):支架内套叠置入治疗ISP的有效性
在142例采用双重保护与血液抽吸法行颈动脉支架置入术(CAS)并于支架置入后行血管内超声(IVUS)的患者中,ISP发生率为12%(17/142),全部ISP病例均行支架内套叠置入;易损斑块和术中碎屑捕获率与ISP发生显著相关,所有ISP患者均未出现神经症状。
要点
- IVUS检测CAS术中ISP很重要,ISP阳性与NASCET≥80%、易损斑块和支架长度相关。
- ISP发生率为12%(17/142),全部ISP病例均行支架内套叠置入。
- ISP阳性患者经可靠保护下充分附加支架内套叠治疗,围手术期并发症低。
核心结论
- 易损斑块和碎屑捕获与ISP发生显著相关;全部ISP病例均行支架内套叠置入并获得良好结果。
研究设计与样本
- 研究纳入142例连续接受CAS并使用双重保护和血液抽吸法、支架置入后行IVUS的患者(128例男性,平均年龄71.7岁;69例有症状),评估CAS结局、ISP发生率及相关因素(斑块特征、支架设计、术中碎屑捕获率和术后弥散加权成像(DWI)阳性率)。
诊断标准与关键数值
- ISP发生率为12%(17/142);17例ISP病例中易损斑块占12例(71%),闭合型支架占13例(71%);术中碎屑捕获率为100%;ISP易感性显著增加与易损斑块和术中碎屑捕获率相关;ISP阳性患者与NASCET≥80%、易损斑块和支架长度相关。
临床应用与阅片要点
- 对CAS术中支架置入后行IVUS检测ISP,ISP阳性患者行支架内套叠置入。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: As in-stent protrusion (ISP) during carotid artery stenting (CAS) may cause postoperative embolism, ISP detection is important. Intravascular ultrasound examination (IVUS) is useful for ISP detection because the blood vessel cross-section can be drawn as a tomogram from the lumen. Our objective was to clarify the occurrence of ISP during CAS using IVUS and relevant factors, and to report the usefulness of stent-in-stent placement when treating ISP.
METHODS: In 142 consecutive patients (128 men, average age 71.7 years; 69 symptomatic) who underwent CAS using dual protection and the blood aspiration method, and subsequent IVUS after stent placement were included. The outcome of CAS, and the occurrence rate of ISP and related factors (plaque characteristics, stent design, intraoperative debris capture rate and postoperative diffusion-weighted imaging (DWI) positive rate) were examined.
RESULTS: All CAS procedures were successful and no major adverse events (MAEs) were observed at 30 days. ISP was found in 12% (17/142), and stent-in-stent placement was performed in all cases. Vulnerable plaques were observed in 12 of 17 ISP cases (71%). A closed stent was used in 13 of 17 ISP cases (71%). The intraoperative debris capture rate was 100%, and no neurological symptoms were observed in any patients. A significant increase in ISP susceptibility was related to vulnerable plaques and the intraoperative debris capture rate.
CONCLUSIONS: Vulnerable plaques and debris capture were significantly correlated with ISP occurrence. In all ISP cases, stent-in-stent placement was performed and good results were obtained.
KEY POINTS: • ISP detection during CAS using IVUS is important. • ISP-positive patients were correlated with NASCET ≥ 80%, vulnerable plaques and stent length. • Adequate additional treatment of stent in stenting under reliable protection against ISP-positive patients achieved low perioperative complications.
引用
- Okazaki T, Sakamoto S, Shinagawa K, et al. Detection of in-stent protrusion (ISP) by intravascular ultrasound during carotid stenting: Usefulness of stent-in-stent placement for ISP. Eur Radiol. 2018. PMID: 30027409. doi:10.1007/s00330-018-5636-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。