下肢血管内与杂交血运重建术中的患者剂量
该回顾性研究分析了259例下肢血管内或杂交血运重建患者的剂量参数,发现血管入路类型对患者剂量影响最大,肱动脉和対侧股总动脉入路的KAP与峰值皮肤剂量最高,所有术式剂量均未超过国际原子能机构(IAEA)提出的患者随访触发值。
要点
- 血管入路类型对患者辐射剂量影响最大,肱动脉和対侧股总动脉入路剂量最高。
- 所有术式的剂量面积乘积(KAP)和透视时间(FT)均未超过IAEA随访触发值。
- 置入支架数量增加和复杂程度提高会显著增加剂量,规划时需考虑。
核心结论
- 不同术式的注册剂量值和FT均未超过IAEA提出的辐射诱导皮肤损伤患者随访触发值。
- 血管入路类型对辐射剂量水平及 resultant KAP、PSD和FT值有最大的负面影响。
- 随着置入支架数量增加和复杂程度提高,剂量值显著增加,规划时应考虑,尤其是接受多次诊断和治疗操作的患者。
研究设计与样本
- 回顾性提取并分析259例患者的数据。
- 按介入类型、血管入路和复杂程度对操作进行分组。
- 分析包括剂量值与手术团队的相关性。
诊断标准与关键数值
- 肱动脉入路:KAP 347 Gy.cm2,FT不适用(NA);対侧股总动脉(CFA)入路:KAP 207 Gy.cm2,FT 153 s;同侧CFA:KAP 96 Gy.cm2,FT 78 s;杂交手术:KAP 77 Gy.cm2,FT 41 s;同侧逆行腘动脉入路:KAP 61 Gy.cm2,FT 53 s。
- 峰值皮肤剂量(PSD):肱动脉入路2053 mGy,対侧CFA 1325 mGy,同侧CFA 748 mGy,杂交手术649 mGy,同侧逆行腘动脉入路566 mGy。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE:: Hybrid surgical methods such as remote endarterectomy and endovascular revascularization are fluoroscopy-guided procedures successfully replacing conventional open surgery for treatment of peripheral artery disease (PAD). The aim of this study was to: (1) evaluate the dose parameters describing exposure of patients undergoing endovascular or hybrid revascularization of the lower limb (below the inguinal ligament); (2) compare the data available in the literature with the evaluations of patients' dose values and related factors for patients undergoing such procedures; (3) examine the correlation of doses with certain parameters; (4) estimate the peak skin dose and assess the potential for radiation-induced skin injuries during the procedures.
METHODS:: Data for 259 patients were extracted retrospectively and analyzed. The procedures were grouped by type of intervention, vascular approach, and level of complexity. The analyses included the correlation of dose values with the operating team.
RESULTS:: The air kerma-area product (KAP) and fluoroscopy time (FT) values greatly varied depending on the procedure type but also among patients undergoing the same procedure. The type of vascular access has the largest impact on patients' doses. The KAP and FT values for brachial artery were: 347 Gy.cm2 and FT: NA; for contralateral common femoral artery (CFA) approach: 207 Gy.cm2 and 153 s; e.g. significantly higher than for ipsilateral CFA: 96 Gy.cm2 and 78 s; for hybrid surgery: 77 Gy.cm2 and 41 s; and for ipsilateral retrograde popliteal approach: 61 Gy.cm2 and 53 s. The same tendency is observed for the peak skin dose (PSD) values: the highest are for brachial artery (2053 mGy) and contralateral CFA (1325 mGy) approach, followed by the ipsilateral CFA (748 mGy), hybrid surgery (649 mGy), and ipsilateral retrograde popliteal approach (566 mGy).
CONCLUSION:: Registered dose values and FT for the different procedures do not exceed the International Atomic Energy Agency (IAEA) proposed trigger values for patients' follow-up for radiation-induced skin injuries. The type of vascular access has the highest negative impact on radiation dose levels and resultant KAP, PSD, and FT values. There is a significant increase of the dose values with increase of the number of inserted stents and the level of complexity. This should be considered in planning, especially for patients who undergo multiple diagnostic and therapeutic procedures.
ADVANCES IN KNOWLEDGE:: This study gives a systematic understanding for patient radiation exposure in endovascular and hybrid revascularization of the lower extremities, thus far absent in the literature.
引用
- Kostova-Lefterova DD, Nikolov NN, Stanev SS, et al. Patient doses in endovascular and hybrid revascularization of the lower extremities. Br J Radiol. 2018. PMID: 30028182. doi:10.1259/bjr.20180176