关于魔角效应的新视角:肌骨放射科医生对该现象知道什么与不知道什么
该研究通过向学术骨放射学家学会成员发放问卷,调查肌骨放射科医生对魔角效应(MAE)在哪些脉冲序列、采集参数、组织及相对主磁场角度下最易出现的认知。结果显示,受访者知道MAE强烈依赖TE并常见于T1W、FSE和PD序列,但对T2W、STIR和DWI序列以及肌腱、韧带、软骨之外组织(如附着点、周围神经、椎间盘)的MAE认识不足,并低估了短TE下可见显著MAE的宽角度范围(半高全宽约40°)。
要点
- 短TE采集时,肌腱、韧带和半月板信号强度取决于其相对于主磁场B0的取向。
- 受访者知道MAE强烈依赖TE且常见于T1W、FSE和PD序列,但对T2W、STIR和DWI序列的MAE认识不足。
- 受访者知道肌腱、韧带和软骨的MAE,但对附着点、周围神经和椎间盘的MAE认识不足。
核心结论
- 含胶原且分子平行排列的组织在相对于B0呈55°取向时信号强度增高;经验丰富的肌骨放射科医生低估了可见显著MAE的图像参数、脉冲序列、组织和胶原取向组合;调查结果凸显对执业放射科医生持续进行MR物理教育的需要。
研究设计与样本
- 向学术骨放射学家学会(SABR)成员发放问卷调查,询问哪些脉冲序列、采集参数、组织及相对B0角度最可能产生MAE。
关键影像表现/征象
- 含胶原且分子平行排列的组织在相对于B0呈55°取向时信号强度增高。
- 短TE采集时,肌腱、韧带和半月板的信号强度取决于其相对于主磁场B0的取向。
诊断标准与关键数值
- 短TE下可见显著MAE的角度范围宽,半高全宽约40°。
临床应用与阅片要点
- 作者指出,调查结果凸显对执业放射科医生持续进行MR物理教育的需要。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Magic angle effects (MAE) are well-recognized in musculoskeletal (MSK) MRI. With short TE acquisitions, the signal intensity of tendons, ligaments, and menisci depend on their orientation relative to the main magnetic field (B0). An interactive resident physics teaching module simulating MR imaging of a tendon forced us to identify and correct several misconceptions we had about MAE. We suspected these misconceptions were shared by other MSK radiologists.
MATERIALS AND METHODS: We surveyed members of the Society of Academic Bone Radiologists (SABR) regarding which pulse sequences, acquisition parameters, tissues and angles relative to B0 were most likely to produce MAE.
RESULTS: Survey respondents knew that MAE strongly depend on TE and commonly appear on T1W, FSE and PD sequences, but were less aware that MAE may also appear on T2W, STIR and DWI sequences. They knew of MAE effects in tendons, ligaments and cartilage, but were less aware of those in entheses, peripheral nerves and intervertebral discs. Respondents underestimated the wide angular range (full-width at half-maximum ≈ 40∘) over which significant MAE can be seen with short TE.
CONCLUSIONS: Collagen-containing tissues with parallel molecular alignment exhibit increased signal intensity when oriented at 55∘ relative to B0. Experienced MSK radiologists were found to underestimate the combinations of image parameters, pulse sequences, tissues and collagen orientations in which significant MAE may be seen. Our survey results highlight the need for ongoing MR physics education for practicing radiologists.
引用
- Richardson ML, Amini B, Richards TL, et al. Some new angles on the magic angle: what MSK radiologists know and don't know about this phenomenon. Skeletal Radiol. 2018. PMID: 29995211. doi:10.1007/s00256-018-3011-8