三维MRI显示膝关节软骨缺损的诊断性能:一项Meta分析
该Meta分析纳入27项研究(共1710次MRI检查),以关节镜和/或开放手术为参考标准,评估三维MRI对膝关节软骨缺损的诊断性能。三维多平面重建特异性高于常规二维MRI(P=.001),三维快速自旋回波序列敏感度和特异度均高于二维MRI(P<.05)。结论认为三维MRI目前诊断性能与二维MRI相当,3.0-T场强、三维快速自旋回波序列和多平面重建可提高诊断性能。
要点
- 三维MRI诊断膝关节软骨缺损的性能与二维MRI相当,3.0-T场强相对1.5-T或更低场强相对诊断比值比为4.05(P=.01)。
- 三维多平面重建特异性高于常规轴位、矢状位和冠状位二维MRI平面(P=.001)。
- 三维快速自旋回波序列敏感度和特异度均高于二维MRI(P<.05)。
核心结论
- 三维MRI目前提供的诊断性能与二维MRI相当,使用3.0-T场强、三维快速自旋回波序列和多平面重建可提高诊断性能。
诊断标准与关键数值
- 3.0-T场强三维MRI相对1.5-T或更低场强的相对诊断比值比为4.05(P=.01)。
- 三维多平面重建特异性高于常规轴位、矢状位和冠状位二维MRI平面(P=.001)。
- 三维快速自旋回波序列敏感度和特异度均高于二维MRI(P<.05)。
临床应用与阅片要点
- 作者结论认为三维MRI目前诊断性能与二维MRI相当。
- 作者结论认为使用3.0-T场强、三维快速自旋回波序列和多平面重建可提高诊断性能。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To determine the diagnostic performance of three-dimensional (3D) MRI for the depiction and characterization of cartilage defects within the knee joint by using arthroscopy and/or open surgery as the standard of reference. Materials and Methods A systematic literature search was performed to extract diagnostic studies published between January 1985 and October 2017. Two independent investigators assessed the methodologic quality of each study by using Quality Assessment of Diagnostic Accuracy Studies 2. Bivariate random-effects model was used to compare the diagnostic odds ratio (DOR) of 3D and two-dimensional (2D) MRI for helping to detect knee cartilage defects and to assess the effect of relevant covariates on diagnostic performance of 3D MRI. Meta-regression analysis was performed to assess DOR of 3D MRI during the last 3 decades. Results Twenty-seven studies (composed of 1710 MRI examinations) were included. Of those, 16 (59%) studies compared the diagnostic performance of 3D and 2D MRI. The diagnostic performance of 3D MRI statistically significantly improved over the last 3 decades (P = .003). Three-dimensional MRI obtained by using 3.0-T field strength had higher DOR relative to 1.5-T or lower field strength (relative DOR, 4.05; P = .01). Three-dimensional multiplanar reformation was associated with higher specificity (P = .001) compared with conventional axial, sagittal, and coronal 2D MRI planes. Three-dimensional fast-spin-echo sequences provided higher sensitivity and specificity (P < .05) than did 2D MRI. Conclusion Three-dimensional MRI currently provides comparable diagnostic performance to two-dimensional MRI, with improvement in diagnostic performance achieved by using 3.0-T field strength, three-dimensional fast-spin-echo sequences, and multiplanar reformation. © RSNA, 2018 Online supplemental material is available for this article.
引用
- Shakoor D, Guermazi A, Kijowski R, et al. Diagnostic Performance of Three-dimensional MRI for Depicting Cartilage Defects in the Knee: A Meta-Analysis. Radiology. 2018. PMID: 30015587. doi:10.1148/radiol.2018180426
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。