双源双能CT中管电压组合对图像伪影和辐射剂量的影响:痛风方案常规80/140 kV与80/150 kV加锡滤过比较
研究纳入74例疑似痛风患者,分别行双源双能CT 80/140 kV(37例)与80/150 kV加锡滤过(37例)扫描,两组年龄、性别及血清尿酸水平匹配。80/150 kV加锡滤过组出现伪影的患者比例显著低于80/140 kV组,剂量长度乘积和有效剂量也显著更低。
要点
- 80/150 kV加锡滤过组伪影发生率30%(11/37),低于80/140 kV组的94.6%(35/37),P<0.001。
- 除运动伪影外,皮肤、甲床、亚毫米、血管、线束硬化及肌腱团块伪影在80/150 kV加锡滤过组均显著更少。
- 80/150 kV加锡滤过组剂量长度乘积104.46±10.66 mGy·cm、有效剂量1.04±0.11 mSv,均显著低于80/140 kV组。
核心结论
- 双源双能CT采用80/150 kV加锡滤过电压组合,与常规80/140 kV相比,可作为减少伪影并降低痛风方案辐射剂量的方法之一。
研究设计与样本
- 研究纳入74例疑似痛风患者,行双源双能CT检查,80/140 kV组37例、80/150 kV加锡滤过组37例,两组年龄、性别及血清尿酸水平匹配。
关键影像表现/征象
- 80/150 kV加锡滤过组出现伪影的患者为11/37(30%),80/140 kV组为35/37(94.6%),P<0.001。
- 除运动伪影外,皮肤、甲床、亚毫米、血管、线束硬化及肌腱团块伪影在80/150 kV加锡滤过组均显著更少。
诊断标准与关键数值
- 80/150 kV加锡滤过组剂量长度乘积104.46±10.66 mGy·cm,80/140 kV组344.70±56.39 mGy·cm,P<0.001。
- 80/150 kV加锡滤过组有效剂量1.04±0.11 mSv,80/140 kV组3.45±0.56 mSv,P<0.001。
临床应用与阅片要点
- 作者认为,双源双能CT系统采用80/150 kV加锡滤过电压组合,与常规80/140 kV相比,可作为减少伪影并降低辐射剂量的方法之一。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: In dual-source CT, dual-energy (DE) performance is affected by various X-ray tube voltage combinations with and without tin filter (Sn). The purpose of this study was to assess the utility of the 80/150 Sn kV voltage combination in terms of image artefact and radiation dose for DECT gout protocol, compared with the conventional 80/140 kV.
METHODS: Seventy-four patients with suspected gout who underwent dual-source DECT examinations scanned at 80/140 kV (n = 37) and at 80/150 Sn kV (n = 37) were included. Patients' age, sex, and serum uric acid levels were matched between the two groups. The types and incidence of image artefacts and radiation dose were evaluated.
RESULTS: The 80/150 Sn kV group had significantly fewer patients with artefacts, compared to the 80/140 kV group [11 (30 %) of 37 vs 35 (94.6 %) of 37, p < 0.001]. Except for the motion artefact, the rest of the artefacts-skin, nail bed, submillimetre, motion, vascular, beam-hardening, clumpy artefact along tendon-were significantly less observed in the 80/150 Sn kV acquisitions. The dose-length product (DLP) and effective dose were significantly lower for the 80/150 Sn kV acquisitions compared with the 8s0/140 kV scans (DLP: 104.46 ± 10.66 mGy·cm vs 344.70 ± 56.39 mGy·cm, p < 0.001; effective dose: 1.04 ± 0.11 mSv vs 3.45 ± 0.56 mSv, p < 0.001).
CONCLUSIONS: The 80/150 Sn kV voltage combination in dual-source DECT system could be used as one of the artefact reduction methods while reducing radiation dose for gout protocol when compared to the conventional 80/140 kV.
KEY POINTS: • DECT has emerged as the leading modality for non-invasive diagnosis of gout. • Various X-ray tube voltage combinations are now feasible in dual-source DECT. • The 80/150 Sn kV acquisition could facilitate artefact reduction in gout protocol.