超声造影时间-强度曲线分析在甲状腺结节鉴别诊断中的价值
该回顾性研究分析了98例患者共103个甲状腺结节的超声造影图像,采用时间-强度曲线分析比较良恶性结节的灌注参数。恶性结节表现为较低的△PI、较晚的△RT和△TTP、较平缓的△MSCWI、较小的△AUCR、△AUCF和△AUC以及较早的△MTT(P<0.05)。多因素分析显示△MSCWI(OR=0.112)和△MTT(OR=0.099)为保护因素。结论认为超声造影时间-强度曲线是鉴别甲状腺结节良恶性的有前景的技术。
要点
- 恶性结节超声造影时间-强度曲线表现为△PI较低、△RT和△TTP较晚、△MSCWI较平缓。
- 恶性结节△AUCR、△AUCF和△AUC较小,△MTT较早。
- 多因素分析中△MSCWI和△MTT为保护因素,OR分别为0.112和0.099。
核心结论
- 超声造影时间-强度曲线分析是鉴别甲状腺结节良恶性的非常有前景且有价值的技术。
研究设计与样本
- 回顾性分析98例患者共103个甲状腺结节的超声造影图像,最终诊断经手术切除后组织学或细针穿刺后细胞学确认。
关键影像表现/征象
- 与良性结节相比,恶性结节时间-强度曲线显示较低的△PI(119.73(115.34, 129.7)vs -15.82(-17.7, -4.31))。
- 恶性结节显示较晚的△RT(-0.27(-0.51, -0.2)vs 0.58(-0.26, 0.65))和△TTP(-0.52(-0.55, -0.36)vs 0.69(-0.04, 0.74))。
- 恶性结节显示较平缓的△MSCWI(6.18(5.29, 7.44)vs -6.1(-7.6, 2.14))和较小的△AUCR(75.7(56.95, 93.22)vs -88.43(-108.89, -73.21))。
- 恶性结节显示较小的△AUCF(112.92(87.77, 137.58)vs -75.55(-105.28, -59.32))、较小的△AUC(181.7(151.50, 219.06)vs -160.64(-200.08, -144.11))和较早的△MTT(2.00(1.85, 3.14)vs -2.09(-2.48, -0.95))(P<0.05)。
诊断标准与关键数值
- 多因素分析显示△MSCWI(OR=0.112;95%CI 0.025-0.507)和△MTT(OR=0.099;95%CI 0.028-0.346)为保护因素。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To assess the feasibility of time-intensity curve (TIC) analysis of contrast-enhanced ultrasound (CEUS) in demonstrating features of benign and malignant thyroid nodules.
METHODS: CEUS images of 98 patients with 103 thyroid nodules were retrospectively analyzed. The final diagnosis was confirmed by histology after surgical excision, or cytology after fine needle aspiration (FNA). Among the benign nodules, which were confirmed using cytology and not surgically removed, those with a >50% cystic component that showed no changes for 1 year on follow-up US, were diagnosed as clinically benign nodules. Similarly, nodules with a <50% cystic component that were aspirated twice and showed no changes for 1 year on follow-up US were also regarded as clinically benign nodules. TIC parameters, including perfusion parameters of relative values (RV) of peak intensity (PI) (△PI), RV of rise time (△RT), RV of time to peak (△TTP), RV of maximum slope coefficient (MSC) of wash-in (△MSCWI), RV of area under the rising curve (△AUCR), clearance parameters of RV of area under the falling curve (△AUCF), RV of MSC of washout (△MSCWO), comprehensive parameters of RV of mean transit time (△MTT), and area under the falling curve (△AUCF) were observed.
RESULTS: Compared with benign thyroid nodules, malignant nodules on TIC analysis of CEUS showed a lower △PI (119.73 (115.34, 129.7), -15.82 (-17.7, -4.31)), later △RT (-0.27 (-0.51, -0.2), 0.58 (-0.26, 0.65)) and △TTP (-0.52 (-0.55, -0.36), 0.69 (-0.04, 0.74)), gentler △MSCWI (6.18 (5.29, 7.44), -6.1 (-7.6, 2.14)), and smaller △AUCR (75.7 (56.95, 93.22), -88.43 (-108.89, -73.21)) in perfusion parameters; a smaller △AUCF (112.92 (87.77, 137.58), -75.55 (-105.28, -59.32)) in clearance parameters; and a smaller △AUC (181.7 (151.50, 219.06), -160.64 (-200.08, -144.11)), and an earlier △MTT (2.00 (1.85, 3.14), -2.09 (-2.48, -0.95)) in comprehensive parameters (P < 0.05). Multivariate analysis of RV of TIC parameters demonstrated that △MSCWI (OR = 0.112; 95% confidence interval [CI], 0.025-0.507) and △MTT (OR = 0.099; 95% CI, 0.028-0.346) were protective factors.
CONCLUSIONS: TIC of CEUS is a very promising and valuable technique for differentiating benign and malignant thyroid nodules.
引用
- Gu F, Han L, Yang X, et al. Value of time-intensity curve analysis of contrast-enhanced ultrasound in the differential diagnosis of thyroid nodules. Eur J Radiol. 2018. PMID: 30017277. doi:10.1016/j.ejrad.2018.05.013