文献速递甲状腺与浅表US

超声计算机辅助诊断甲状腺结节:初步临床经验

Computer-Aided Diagnosis of Thyroid Nodules via Ultrasonography: Initial Clinical Experience.
PubMed 文献 · Korean J Radiol · 2018-06-14

研究纳入2016年6月至7月间50例连续患者的117个甲状腺结节,由放射科医师使用集成实时CAD的超声扫描仪进行检查,比较医师、CAD系统及CAD辅助医师对甲状腺癌的诊断性能。CAD系统与医师的诊断性能无显著差异;CAD辅助医师较单独医师敏感度提高但特异度与阳性预测值降低,较单独CAD系统敏感度与阴性预测值提高;CAD系统可能作为放射学干预的辅助手段。

要点

  • CAD系统诊断甲状腺癌的敏感度80.0%、特异度88.1%,与放射科医师无显著差异。
  • CAD辅助医师较单独医师敏感度提高(92.0% vs. 84.0%),但特异度(85.1% vs. 95.5%)与阳性预测值(82.1% vs. 93.3%)降低。
  • CAD辅助医师较单独CAD系统敏感度与阴性预测值提高,特异度与阳性预测值无显著差异。

核心结论

  • CAD系统可能作为放射学干预中诊断甲状腺癌的辅助手段。

研究设计与样本

  • 前瞻性研究,纳入2016年6月至2016年7月间50例连续患者的117个甲状腺结节,由一名放射科医师使用集成实时CAD的超声扫描仪进行检查,比较医师、CAD系统及CAD辅助医师对甲状腺癌的诊断性能。

诊断标准与关键数值

  • CAD系统诊断甲状腺癌的敏感度80.0%、特异度88.1%、阳性预测值83.3%、阴性预测值85.5%、准确率84.6%,与放射科医师无显著差异(p > 0.05)。
  • CAD辅助医师诊断甲状腺癌的敏感度92.0% vs. 单独医师84.0%(p = 0.037),特异度85.1% vs. 95.5%(p = 0.005),阳性预测值82.1% vs. 93.3%(p = 0.008)。
  • CAD辅助医师诊断甲状腺癌的敏感度92.0% vs. 单独CAD系统80.0%(p = 0.009),阴性预测值93.4% vs. 88.9%(p = 0.013),特异度85.1% vs. 88.1%(p = 0.151),阳性预测值82.1% vs. 83.3%(p = 0.613)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To prospectively evaluate the diagnostic performance of computer-aided diagnosis (CAD) for detection of thyroid cancers via ultrasonography (US).

MATERIALS AND METHODS: This study included 50 consecutive patients with 117 thyroid nodules on US during the period between June 2016 and July 2016. A radiologist performed US examinations using real-time CAD integrated into a US scanner. We compared the diagnostic performance of radiologist, the CAD system, and the CAD-assisted radiologist for the detection of thyroid cancers.

RESULTS: The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of the CAD system were 80.0, 88.1, 83.3, 85.5, and 84.6%, respectively, and were not significantly different from those of the radiologist (p > 0.05). The CAD-assisted radiologist showed improved diagnostic sensitivity compared with the radiologist alone (92.0% vs. 84.0%, p = 0.037), while the specificity and PPV were reduced (85.1% vs. 95.5%, p = 0.005 and 82.1% vs. 93.3%, p = 0.008). The radiologist assisted by the CAD system exhibited better diagnostic sensitivity and NPV than the CAD system alone (92.0% vs. 80.0%, p = 0.009 and 93.4% vs. 88.9%, p = 0.013), while the specificities and PPVs were not significantly different (88.1% vs. 85.1%, p = 0.151 and 83.3% vs. 82.1%, p = 0.613, respectively).

CONCLUSION: The CAD system may be an adjunct to radiological intervention in the diagnosis of thyroid cancer.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Yoo YJ, Ha EJ, Cho YJ, et al. Computer-Aided Diagnosis of Thyroid Nodules via Ultrasonography: Initial Clinical Experience. Korean J Radiol. 2018. PMID: 29962872. doi:10.3348/kjr.2018.19.4.665

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。