DCE-MRI影像组学特征预测乳腺癌Ki67表达
该回顾性研究纳入2015年377例中国浸润性乳腺癌患者,其中Ki67低表达(增殖指数<14%)53例、高表达(>14%)324例,从DCE-MRI病灶分割区提取56个影像组学特征,用LASSO筛选特征后以朴素贝叶斯、k近邻和支持向量机分类,朴素贝叶斯表现最佳(AUC 0.773),提示影像组学特征与Ki67表达相关。
要点
- DCE-MRI影像组学特征与乳腺癌Ki67表达相关。
- 朴素贝叶斯分类器表现最佳,AUC 0.773。
- LASSO筛选的对比度、熵和线样性是预测特征(p<0.05)。
核心结论
- 从DCE-MRI提取的乳腺肿瘤定量影像组学特征与乳腺癌Ki67表达相关,未来需更大规模研究进一步评估。
研究设计与样本
- 经机构审查委员会批准的回顾性研究,纳入2015年377例中国浸润性乳腺癌女性,其中Ki67低表达(增殖指数<14%)53例、高表达(>14%)324例。
诊断标准与关键数值
- 从分割病灶区提取56个定量影像组学特征(形态学、灰度统计和纹理特征),LASSO筛选最具预测性特征集;朴素贝叶斯分类器AUC 0.773、准确率0.757、敏感度0.777、特异度0.769;对比度、熵和线样性三个特征被LASSO选中且在分类中具统计学显著性(p<0.05)。
局限性
- 未来需更大规模研究以进一步评估该发现。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To investigate whether quantitative radiomics features extracted from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) are associated with Ki67 expression of breast cancer.
MATERIALS AND METHODS: This institutional review board-approved retrospective study comprised 377 Chinese women who were diagnosed with invasive breast cancer in 2015. This cohort included 53 low-Ki67 expression (Ki67 proliferation index less than 14%) and 324 cases with high-Ki67 expression (Ki67 proliferation index more than 14%). A binary-classification of low-versus high- Ki67 expression was performed. A set of 56 quantitative radiomics features, including morphological, greyscale statistic, and texture features, were extracted from the segmented lesion area. Three machine learning classification methods, including naive Bayes, k-nearest neighbour and support vector machine, were employed for the classification and the least absolute shrink age and selection operator (LASSO) method was used to select most predictive features set for the classifiers. Classification performance was evaluated by the area under receiver operating characteristic curve (AUC), accuracy, sensitivity, and specificity.
RESULES: The model that used naive Bayes classification method achieved the best performance than the other two methods, yielding 0.773 AUC, 0.757 accuracy, 0.777 sensitivity and 0.769 specificity. Three most predictive features, i.e., contrast, entropy and line likeness, were selected by the LASSO method and showed a statistical significance (p<0.05) in the classification.
CONCLUSION: The present study showed that quantitative radiomics imaging features of breast tumour extracted from DCE-MRI are associated with breast cancer Ki67 expression. Future larger studies are needed in order to further evaluate the findings.
引用
- Ma W, Ji Y, Qi L, et al. Breast cancer Ki67 expression prediction by DCE-MRI radiomics features. Clin Radiol. 2018. PMID: 29970244. doi:10.1016/j.crad.2018.05.027
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。