文献速递妇产影像腹部MR

胎盘附着异常MRI个体化诊断标准的观察者间一致性与诊断效能

Interobserver agreement and diagnostic performance of individual MRI criteria for diagnosis of placental adhesion disorders.
PubMed 文献 · Clin Radiol · 2018-07-02

对28例孕妇胎盘MRI进行盲法评估,3名不同年资放射科医生判断7项诊断标准,以病理和临床信息为参考标准。T2加权像胎盘内暗带是最敏感、最特异且一致性最高(kappa=0.7)的标准;子宫膨出和胎盘异质性未提高诊断准确率;DWI对经验最少者提高敏感度但降低特异度,对经验较多者无变化。

要点

  • T2加权像胎盘内暗带是诊断胎盘附着异常最敏感、最特异且一致性最高(kappa=0.7)的MRI标准。
  • 子宫膨出(kappa=0.42)和胎盘异质性(kappa=0.48)未提高诊断准确率。
  • DWI对经验最少者提高敏感度但降低特异度,对经验较多者敏感度和特异度无变化。

核心结论

  • 评估胎盘内暗带是MRI诊断胎盘附着异常最敏感、最特异且可重复性最高的标准。

研究设计与样本

  • 盲法评估28例随机选取孕妇的胎盘MRI,其中18例有胎盘附着异常、10例无胎盘附着异常。
  • 由3名分别具有10年、5年和2年胎盘MRI判读经验的放射科医生独立评估。
  • 参考标准为盲法复习的胎盘组织学及分娩时临床信息。

关键影像表现/征象

  • 评估的MRI征象包括前置胎盘、胎盘内暗带、胎盘异质性、子宫膨出、子宫浆膜「蓬乱狗」样表现、主观印象的胎盘外侵犯及弥散加权成像上的胎盘内暗带。

诊断标准与关键数值

  • T2加权成像上胎盘内暗带在3名读者中均为最敏感、最特异且一致性最高(kappa=0.7)的胎盘附着异常诊断标准。
  • 子宫膨出的观察者间一致性kappa=0.42,胎盘异质性的观察者间一致性kappa=0.48,二者未提高诊断准确率。
  • DWI对经验最少的读者提高敏感度但降低特异度,对经验较多的读者敏感度和特异度均无变化。

临床应用与阅片要点

  • 判读胎盘MRI时可将T2加权像胎盘内暗带作为诊断胎盘附着异常的主要可靠征象。
  • 子宫膨出和胎盘异质性的观察者间一致性中等,单独用于诊断时价值有限。
  • 经验较少的判读者使用DWI需注意其可能提高敏感度但降低特异度。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To assess the diagnostic accuracy of several criteria for the diagnosis of placental adhesion disorder (PAD) on magnetic resonance imaging (MRI) and to assess interobserver agreement and reader accuracy based on years of interpretive experience.

MATERIALS AND METHODS: Blinded evaluation of the placental MRI studies of 28 randomly selected women, 18 with PADs and 10 without PADs, was undertaken by three radiologists with 10, 5, and 2 years' experience in placental MRI interpretation. The presence of placenta praevia, dark intraplacental bands, heterogeneity, uterine bulging, "shaggy dog" appearance of the uterine serosa, subjective impression of extraplacental invasion, and dark intraplacental bands on diffusion-weighted imaging were assessed. Placental histology was reviewed blinded to the original reports and to MRI interpretation and this, along with clinical information at the time of delivery, formed the reference standard.

RESULTS: Dark intraplacental bands on T2-weighted imaging were the most sensitive and specific as well as the most agreed upon (kappa=0.7) criterion for PAD for the three readers. Assessment of uterine bulging (kappa=0.42) and placental heterogeneity (kappa=0.48) did not improve diagnostic accuracy. DWI improved sensitivity but decreased specificity for the least experienced reader and did not change sensitivity or specificity for the more experienced readers.

CONCLUSION: Assessment of the placenta for dark bands is the most sensitive, specific, and reproducible criterion for diagnosis of PADs using MRI.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Goergen SK, Posma E, Wrede D, et al. Interobserver agreement and diagnostic performance of individual MRI criteria for diagnosis of placental adhesion disorders. Clin Radiol. 2018. PMID: 30041952. doi:10.1016/j.crad.2018.05.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。