文献速递泌尿生殖MR

扩散加权成像衍生的定量表观扩散系数有潜力避免对多参数MRI检出的PI-RADS 4和5病灶进行不必要的MRI引导活检

Quantitative Apparent Diffusion Coefficient Derived From Diffusion-Weighted Imaging Has the Potential to Avoid Unnecessary MRI-Guided Biopsies of mpMRI-Detected PI-RADS 4 and 5 Lesions.
PubMed 文献 · Invest Radiol · 2018-01-01

该回顾性研究纳入101例经MRI引导活检证实的PI-RADS 4和5前列腺病灶(52恶性、49良性),两位阅片者独立重复测量最小、平均和最大ADC值。最小ADC值诊断性能最佳(总体AUC R1:0.801、R2:0.796),并确定了纳入和排除阈值,显示有潜力避免32.7%(16/49)的不必要活检。

要点

  • 最小ADC值诊断性能最佳,总体AUC为R1:0.801、R2:0.796。
  • 最小ADC值的阅片者间一致性界限最窄,为-8.6%至9.9%。
  • 基于最小ADC值的纳入和排除阈值有潜力避免32.7%(16/49)的不必要活检。

核心结论

  • 多参数MRI检出的PI-RADS 4和5病灶中,定量ADC测量有潜力避免高达33%的不必要MRI引导活检。

研究设计与样本

  • 回顾性、机构审查委员会批准的研究,纳入101例男性(平均年龄62.8岁)的101个PI-RADS 4和5前列腺病灶(52恶性、49良性),均经MRI引导活检证实;两位阅片者在不知活检结果的情况下,按PI-RADS v2推荐在活检病灶周围绘制二维感兴趣区,独立重复测量最小、平均和最大ADC值。

诊断标准与关键数值

  • 最小ADC值诊断前列腺癌的总体AUC为R1:0.801、R2:0.796;外周带AUC为R1:0.814、R2:0.805;移行带AUC为R1:0.786、R2:0.779。
  • 最小ADC值的阅片者间一致性界限为-8.6%至9.9%。
  • 确定了诊断前列腺癌的纳入和排除阈值,有潜力避免32.7%(16/49)的不必要活检。

临床应用与阅片要点

  • 对多参数MRI检出的PI-RADS 4和5病灶,可测量最小ADC值以辅助判断是否可避免不必要的MRI引导活检。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The aim of this study was to evaluate the potential of diffusion-weighted imaging-derived apparent diffusion coefficient (ADC) measurements to obviate unnecessary biopsies in multiparametric MRI-detected PI-RADS 4 and 5 lesions.

MATERIALS AND METHODS: This retrospective, institutional review board-approved study investigated 101 PI-RADS 4 and 5 prostate lesions (52 malignant, 49 benign) verified by in-bore MRI-guided biopsy in 101 men (mean age, 62.8 years). Two readers, who were not aware of the biopsy results independently and repeatedly measured minimum, mean, and maximum ADC from diffusion-weighted imaging measurements (in line with PI-RADS v2 recommendations) using a 2-dimensional region of interest drawn around the biopsied lesions. Diagnostic performance was evaluated using receiver operating characteristic statistics and reproducibility statistics were calculated.

RESULTS: The best diagnostic performance (overall area under the receiver operating characteristic curve [AUC] R1: 0.801; R2: 0.796 peripheral zone AUC R1:0.814, R2: 0.805; transitional zone AUC R1:0.786, R2:0.779) and the tightest limits of interreader agreement (-8.6% to 9.9%) were found in minimum ADC values. Rule-in and rule-out thresholds for diagnosis of prostate cancer were identified, demonstrating a potential to avoid unnecessary biopsies in 32.7% (16/49).

CONCLUSIONS: Quantitative ADC measurement in multiparametric MRI-detected PI-RADS 4 and 5 lesions has the potential to avoid unnecessary MRI-guided biopsies in up to 33%.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Polanec SH, Helbich TH, Bickel H, et al. Quantitative Apparent Diffusion Coefficient Derived From Diffusion-Weighted Imaging Has the Potential to Avoid Unnecessary MRI-Guided Biopsies of mpMRI-Detected PI-RADS 4 and 5 Lesions. Invest Radiol. 2018. PMID: 29985792. doi:10.1097/RLI.0000000000000498

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。