多排CT评估胰槽脂肪间隙
回顾性分析460例正常人与25例胰槽胰腺炎或癌患者,用5mm和1mm层厚平扫多排CT按4级法评估胰槽脂肪间隙显示程度;正常组>80岁者4级显示更常见,病理组均未见4级显示,≤50%显示阈值在>60岁患者中检出可能异常的敏感度95%、特异度82%。
要点
- 正常人群胰槽脂肪间隙4级显示在>80岁者占78.6%,高于较年轻年龄组。
- 胰槽癌或胰槽胰腺炎患者均未见胰槽脂肪间隙4级显示。
- >60岁患者中,胰槽脂肪间隙显示≤50%检出可能异常的敏感度95%、特异度82%。
核心结论
- 胰槽脂肪间隙显示程度可能是检出胰槽异常的良好预测指标。
研究设计与样本
- 回顾性研究,正常组460例、病理组25例(胰槽胰腺炎或癌),采用5mm和1mm层厚平扫轴位多排CT图像,由两名研究者独立按4级法评估胰槽脂肪间隙显示程度。
关键影像表现/征象
- 正常组中胰槽脂肪间隙4级显示在>80岁者占78.6%,较年轻年龄组更常见。
- 胰腺萎缩和脂肪浸润显著改善脂肪间隙显示。
- 病理组中胰槽癌和胰槽胰腺炎均未见胰槽脂肪间隙4级显示。
诊断标准与关键数值
- 胰槽脂肪间隙显示程度采用4级法:1级显示0-25%,2级显示26-50%,3级显示51-75%,4级显示76-100%。
- 观察者间一致性的k值为0.95。
- 以胰槽脂肪间隙显示≤50%为阈值,在>60岁患者中检出可能异常的敏感度95%、特异度82%。
临床应用与阅片要点
- 阅片时可关注胰槽脂肪间隙的显示程度,正常人群中随年龄增长及胰腺萎缩、脂肪浸润显示更充分。
- 在>60岁患者中,胰槽脂肪间隙显示≤50%时需警惕胰槽异常的可能。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To assess the pancreatic groove fat plane in the normal population and compare this with the fat plane in patients with groove pancreatitis or carcinoma using multidetector computed tomography (CT).
MATERIAL AND METHODS: The pancreatic groove fat plane was evaluated retrospectively in 460 normal subjects (normal group), and in 25 patients with groove pancreatitis or carcinoma (pathology group) using 5 mm- and 1 mm-thick slices of unenhanced axial multidetector CT images. Two investigators independently assessed the degree of pancreatic groove fat plane visualisation using a four-point scale (grade 1: visualisation of 0-25%, grade 2: 26-50%, grade 3: 51-75%, grade 4: 76-100%). Pancreatic parenchymal condition, age, sex, body mass index, diabetes mellitus, and dyslipidaemia were also evaluated.
RESULTS: The interobserver agreement for the visualisation grades was almost perfect (k-value = 0.95). In the normal group, grade 4 visualisation of the pancreatic groove fat plane was more common in those aged >80 years (78.6%) compared with younger age groups. Pancreatic atrophy and fatty infiltration significantly improved fat plane visualisation. In the pathology group, grade 4 visualisation of the pancreatic groove fat plane was not seen in either groove carcinoma or pancreatitis. A cut-off point of ≤50% visualisation of the pancreatic groove fat plane showed 95% sensitivity and 82% specificity for detecting possible abnormalities in older patients (>60 years). The clinical factors investigated were not significantly related to pancreatic groove fat plane visualisation.
CONCLUSION: Pancreatic groove fat plane visualisation could be a good predictor for detecting groove abnormalities.
引用
- Silman C, Matsumoto S, Mori H, et al. Evaluation of the fat plane of the pancreatic groove using multidetector CT. Clin Radiol. 2018. PMID: 30029836. doi:10.1016/j.crad.2018.06.009
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。