文献速递腹部技术与安全US

二维剪切波弹性成像评估慢性乙型肝炎肝纤维化:根据丙氨酸氨基转移酶水平调整截断值可提高准确性

Shear wave elastography for liver fibrosis in chronic hepatitis B: Adapting the cut-offs to alanine aminotransferase levels improves accuracy.
PubMed 文献 · Eur Radiol · 2018-07-23

该研究纳入慢性乙型肝炎感染并接受肝活检评估肝纤维化的患者,建立并验证基于丙氨酸氨基转移酶(ALT)水平的二维剪切波弹性成像(2D-SWE)肝硬度测量双截断值。结果显示,ALT≤2倍正常上限(ULN)与>2×ULN患者分别采用不同的排除和确认截断值,对显著纤维化(≥F2)和肝硬化(F4)的诊断总体准确率均超过90%,且衍生队列与验证队列间准确率无显著差异(均p>0.05)。

要点

  • ALT≤2×ULN者排除显著纤维化(≥F2)的截断值为5.4 kPa,确认截断值为9.0 kPa;ALT>2×ULN者分别为7.1 kPa和11.2 kPa。
  • ALT≤2×ULN者排除肝硬化(F4)的截断值为8.1 kPa,确认截断值为12.3 kPa;ALT>2×ULN者分别为11.9 kPa和24.7 kPa。
  • ALT调整后的双截断值对显著纤维化和肝硬化的诊断总体准确率均超过90%。

核心结论

  • 基于ALT水平调整的2D-SWE肝硬度测量双截断值对慢性乙型肝炎患者显著纤维化和肝硬化的诊断具有高准确率。

研究设计与样本

  • 研究纳入接受肝活检评估肝纤维化的慢性乙型肝炎感染患者,连续纳入;前515例为衍生队列,后421例为验证队列;采用二维剪切波弹性成像测量肝硬度,以肝活检为参考标准。

诊断标准与关键数值

  • 显著纤维化(≥F2):ALT≤2×ULN者排除截断值5.4 kPa、确认截断值9.0 kPa;ALT>2×ULN者排除截断值7.1 kPa、确认截断值11.2 kPa。
  • 肝硬化(F4):ALT≤2×ULN者排除截断值8.1 kPa、确认截断值12.3 kPa;ALT>2×ULN者排除截断值11.9 kPa、确认截断值24.7 kPa。
  • 确认阈值定义为阳性似然比≥10,排除阈值定义为阴性似然比≤0.1。
  • 双截断值在衍生队列和验证队列中对显著纤维化和肝硬化存在或缺失的诊断总体准确率均超过90%,两队列间准确率无显著差异(均p>0.05)。

临床应用与阅片要点

  • 解读2D-SWE肝硬度值时,应按患者ALT水平(≤2×ULN或>2×ULN)选用相应的排除和确认截断值。
  • ALT>2×ULN患者的ALT调整截断值明显高于ALT≤2×ULN患者。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To determine and validate alanine aminotransferase (ALT)-adapted dual cut-offs of liver stiffness measurements (LSMs) for assessing liver fibrosis with two-dimensional shear wave elastography (2D-SWE) in patients with chronic hepatitis B (CHB) infection.

METHODS: Patients with CHB infection who underwent liver biopsy to assess liver fibrosis were consecutively included. 2D-SWE confirmation thresholds with a positive likelihood ratio ≥10 and 2D-SWE exclusion thresholds with a negative likelihood ratio ≤0.1 were identified to rule in or rule out significant fibrosis and cirrhosis, respectively.

RESULTS: The first 515 patients (index cohort) and the next 421 patients (validation cohort) were included in the final analysis. The low and high cut-offs to rule out and rule in patients with significant fibrosis (≥ F2) were 5.4 kPa and 9.0 kPa, respectively, in patients with ALT levels ≤ 2 × the upper limit of normal (ULN) and 7.1 kPa and 11.2 kPa in patients with ALT levels > 2 × ULN. For cirrhosis (F4), the corresponding values were 8.1 kPa and 12.3 kPa in patients with ALT levels ≤ 2 × ULN and 11.9 kPa and 24.7 kPa in patients with ALT levels > 2 × ULN. The dual cut-off values showed an overall accuracy of more than 90% for diagnosis of the presence or absence of significant fibrosis and cirrhosis in the index and validation cohorts. There were no significant differences in the accuracy values between the cohorts (all p>0.05).

CONCLUSION: The ALT-adapted dual cut-offs of LSMs showed high accuracy for diagnosis of the presence or absence of significant fibrosis and cirrhosis in patients with CHB infection.

KEY POINTS: • The ALT-adapted dual cut-off values of LSMs showed high accuracy for diagnosis of the presence or absence of significant fibrosis and cirrhosis. • ALT levels did not influence the overall diagnostic accuracy for predicting significant fibrosis and cirrhosis. • The ALT-adapted dual cut-offs in patients with ALT levels > 2 × ULN were markedly higher than those in patients with ALT levels ≤ 2 × ULN.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Zeng J, Zheng J, Jin JY, et al. Shear wave elastography for liver fibrosis in chronic hepatitis B: Adapting the cut-offs to alanine aminotransferase levels improves accuracy. Eur Radiol. 2018. PMID: 30039224. doi:10.1007/s00330-018-5621-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。