全剂量腹部CT加权滤波反投影与半剂量改进正弦图确认迭代重建(SAFIRE*)的图像噪声与图像质量比较
该回顾性研究纳入53例连续患者,采用双源单能腹部增强CT协议,比较全剂量图像经加权滤波反投影(wFBP)重建与半剂量图像经wFBP及SAFIRE*强度1-5重建的噪声、信噪比和主观图像质量。结果显示SAFIRE*强度递增时噪声逐步降低、SNR升高(p<0.01),半剂量SAFIRE*强度4和5的客观噪声低于全剂量wFBP、SNR更高(p<0.01),主观诊断可接受性、主观噪声和空间分辨率也随强度递增而改善(p<0.01)。作者结论为半剂量SAFIRE*强度4和5的图像质量优于全剂量wFBP,SAFIRE*可能允许约50%的剂量降低。
要点
- 半剂量SAFIRE*强度4和5的客观噪声低于全剂量wFBP、SNR更高(p<0.01)。
- SAFIRE*强度递增时主观诊断可接受性提高、主观噪声降低、空间分辨率提高(p<0.01)。
- 作者认为半剂量SAFIRE*强度4和5图像质量优于全剂量wFBP,可能允许约50%剂量降低。
核心结论
- 半剂量CT图像经SAFIRE*强度4和5重建后图像质量优于全剂量wFBP重建图像;SAFIRE*可能允许相对于wFBP约50%的剂量降低。
研究设计与样本
- 回顾性研究,纳入53例连续患者,采用标准化的双源单能腹部增强CT协议,半剂量图像由单侧探测器数据回顾性生成;全剂量数据采用wFBP重建,半剂量数据采用wFBP及SAFIRE*强度1-5重建;以感兴趣区分析评估SNR和噪声,并由两名读者采用10分制对诊断可接受性、主观噪声和空间分辨率进行评分;统计分析采用重复测量方差分析、Wilcoxon符号秩检验和Cohen κ检验。
诊断标准与关键数值
- SAFIRE*强度1-5递增时噪声逐步降低、SNR升高(p<0.01);半剂量SAFIRE*强度4和5较全剂量wFBP客观噪声降低、SNR升高(p<0.01);主观诊断可接受性随强度递增而提高、主观噪声降低、空间分辨率提高(p<0.01)。
临床应用与阅片要点
- 作者结论认为半剂量SAFIRE*强度4和5图像质量优于全剂量wFBP,SAFIRE*可能允许约50%的剂量降低。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To retrospectively compare the image noise, signal-to-noise ratio (SNR), and subjective image quality between CT images acquired with a dual-source, split-dose imaging protocol reconstructed at full and half doses with weighted filtered back projection (wFBP) and an improved sinogram-affirmed iterative reconstruction algorithm (SAFIRE*).
METHODS: Fifty-three consecutive patients underwent contrast-enhanced CT of the abdomen using a standardized dual-source, single energy CT protocol. Half-dose images were retrospectively generated using data from one detector only. Full-dose datasets were reconstructed with wFBP, while half-dose datasets were reconstructed with wFBP and SAFIRE* strengths 1-5. Region of interest analysis was performed to assess SNR and noise. Diagnostic acceptability, subjective noise, and spatial resolution were graded on a 10-point scale by two readers. Statistical analysis was carried out with repeated measures analysis of variance, Wilcoxon signed rank test, and Cohen's κ test.
RESULTS: With the increasing strengths of SAFIRE*, a progressive reduction in noise and increase in SNR (p < 0.01) was observed. There was a statistically significant decrease in objective noise and increase in SNR in half-dose SAFIRE* strength 4 and 5 reconstructions compared to full-dose reconstructions using wFBP (p < 0.01). Qualitative analysis revealed a progressive increase in diagnostic acceptability, decrease in subjective noise and increase in spatial resolution for half-dose images reconstructed with the increasing strengths of SAFIRE* (p < 0.01).
CONCLUSIONS: Half-dose CT images reconstructed with SAFIRE* at strength 4 and 5 have superior image quality compared to full-dose images reconstructed with wFBP. SAFIRE* potentially allows dose reductions in the order of 50% over wFBP.
引用
- Choy S, Parhar D, Lian K, et al. Comparison of image noise and image quality between full-dose abdominal computed tomography scans reconstructed with weighted filtered back projection and half-dose scans reconstructed with improved sinogram-affirmed iterative reconstruction (SAFIRE*). Abdom Radiol (NY). 2019. PMID: 29980828. doi:10.1007/s00261-018-1687-9