文献速递腹部儿科影像技术与安全CT

儿科腹盆腔CT多期相采集是常见做法,并导致不必要的辐射剂量

Multiphase acquisitions in pediatric abdominal-pelvic CT are a common practice and contribute to unnecessary radiation dose.
PubMed 文献 · Pediatr Radiol · 2018-07-07

本研究回顾性分析2012年1月1日至2015年12月31日上传至PACS的院外腹盆腔增强CT 754例,并与本院939例对比;院外53%为两期相、2%为三期相及以上,本院多期相仅12%;院外CTDIvol为9.4 mGy,本院为3.5 mGy,院外是本院2.7倍。

要点

  • 院外儿科腹盆腔增强CT中53%(399/754)为两期相,2%(14/754)为三期相及以上,多期相比例高于本院。
  • 院外有剂量资料的增强CT中,CTDIvol均值为9.4 mGy,本院为3.5 mGy,院外是本院2.7倍(P<0.0001)。
  • 作者主张多期相率高的机构应取消儿童常规腹盆腔增强CT的多期相采集。

核心结论

  • 院外影像机构的常规儿童腹盆腔增强CT多期相采集比专门的儿科机构更频繁,并导致不必要的辐射剂量;院外两期相检查的剂量可能高达儿科影像中心单期相检查的4至6倍;作者主张多期相率高的机构应取消儿童常规腹盆腔增强CT的多期相采集。

研究设计与样本

  • 回顾性分析,纳入2012年1月1日至2015年12月31日上传至PACS的院外腹盆腔增强CT 754例(来自104家院外影像机构),并与通过美国放射学会剂量指数注册库查询的本院939例腹盆腔增强CT对比;排除腹部或盆腔肿块、创伤或尿漏指征的检查;研究经机构审查委员会批准并符合HIPAA。

诊断标准与关键数值

  • 多期相定义为增强CT包含2期相、3期相或更多期相;院外754例中53%(399/754)有2期相,2%(14/754)有3期相或更多;本院939例中12%(115)为多期相检查;院外74%的多期相检查由104家机构中的9家完成。

临床应用与阅片要点

  • 作者主张多期相率高的影像机构应取消儿童常规腹盆腔增强CT的多期相采集。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Many patients at our pediatric hospital have had a contrast-enhanced CT of the abdomen and pelvis performed by an outside imaging facility before admission. We have noticed that many of these exams are multiphase, which may contribute to unnecessary radiation dose.

OBJECTIVE: To determine the frequency of multiphase acquisitions and radiation dose indices in contrast-enhanced CTs of the abdomen and pelvis performed by outside imaging facilities in patients who were subsequently transferred to our pediatric hospital for care, and compare these metrics to contrast-enhanced CTs of the abdomen and pelvis performed internally.

MATERIALS AND METHODS: A retrospective analysis was performed of contrast-enhanced CTs of the abdomen and pelvis from outside imaging facilities uploaded to our picture archiving and communication system (PACS) between January 1, 2012, and December 31, 2015. CT images and dose pages were reviewed to determine the number of phases and dose indices (CT dose index-volume [CTDIvol], dose-length product, size-specific dose estimate). Exams for abdominal or pelvic mass, trauma or urinary leak indications were excluded. Data were compared to internally acquired contrast-enhanced CTs of the abdomen and pelvis by querying the American College of Radiology (ACR) Dose Index Registry. This review was institutional review board and HIPAA compliant.

RESULTS: There were 754 contrast-enhanced CTs of the abdomen and pelvis from 104 outside imaging facilities. Fifty-three percent (399/754) had 2 phases, and 2% (14/754) had 3 or more phases. Of the 939 contrast-enhanced CTs of the abdomen and pelvis performed internally, 12% (115) were multiphase exams. Of 88% (664) contrast-enhanced CTs of the abdomen and pelvis from outside imaging facilities with dose data, CTDIvol was 2.7 times higher than our institution contrast-enhanced CTs of the abdomen and pelvis (939) for all age categories as defined by the ACR Dose Index Registry (mean: 9.4 vs. 3.5 mGy, P<0.0001). The majority (74%) of multiphase exams were performed by 9 of 104 outside imaging facilities.

CONCLUSION: Multiphase acquisitions in routine contrast-enhanced CT of the abdomen and pelvis exams at outside imaging facilities are more frequent than those at a dedicated pediatric institution and contribute to unnecessary radiation dose. A contrast-enhanced CT of the abdomen and pelvis exam from an outside imaging facility with two passes may have as much as four times to six times the dose as the same exam performed with a single pass at a pediatric imaging center. We advocate for imaging facilities with high multiphase rates to eliminate multiple phases from routine contrast-enhanced CT of the abdomen and pelvis exams in children.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Rostad BS, Applegate KE, Kim T, et al. Multiphase acquisitions in pediatric abdominal-pelvic CT are a common practice and contribute to unnecessary radiation dose. Pediatr Radiol. 2018. PMID: 29980861. doi:10.1007/s00247-018-4192-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。