MR纹理分析:预测结直肠癌肝转移患者化疗反应的潜在影像生物标志物
本研究纳入26例连续患者的193个不可切除结直肠癌肝转移灶,在治疗前T2加权图像上提取直方图与灰度共生矩阵纹理特征,按病灶大小变化分为反应组与无反应组。方差、熵1、对比度、熵2升高及角二阶矩、相关性、逆差矩降低与化疗良好反应独立相关,AUC为0.602-0.784。方差与角二阶矩联合模型最高AUC为0.814。
要点
- 治疗前T2WI纹理特征中,方差与角二阶矩是鉴别化疗反应病灶的潜在预测因子,联合模型AUC最高达0.814。
- 方差、熵1、对比度、熵2升高及角二阶矩、相关性、逆差矩降低与化疗良好反应独立相关(P<0.05)。
- 纹理分析在病灶最大横截面上手动勾画感兴趣区,由两名放射科医师共识完成。
核心结论
- 治疗前T2图像上的MR纹理特征有潜力预测结直肠癌肝转移的化疗治疗反应。
研究设计与样本
- 研究纳入2014年8月至2016年2月本机构26例连续不可切除结直肠癌肝转移患者共193个肝转移灶,按病灶大小变化分为反应组与无反应组;在T2加权图像上由两名放射科医师共识于病灶最大横截面积手动勾画感兴趣区行纹理分析。
诊断标准与关键数值
- 提取5个直方图特征(均值、方差、偏度、峰度、熵1)和5个灰度共生矩阵特征(角二阶矩、熵2、对比度、相关性、逆差矩);方差、熵1、对比度、熵2升高及角二阶矩、相关性、逆差矩降低与化疗良好反应独立相关(P<0.05),AUC为0.602-0.784;多变量logistic回归中方差(P<0.001)与角二阶矩(P=0.001)仍为潜在预测因子,二者联合最高AUC为0.814。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The purpose of the study was to determine whether the pre-treated MR texture features of colorectal liver metastases (CRLMs) are predictive of therapeutic response after chemotherapy.
METHODS: The study included twenty-six consecutive patients (a total of 193 liver metastasis) with unrespectable CRLMs at our institution from August 2014 to February 2016. Lesions were categorized into either responding group or non-responding group according to changes in size. Texture analysis was quantified on T2-weighted images by two radiologists with consensus on regions of interest which were manually drawn on the largest cross-sectional area of the lesions. Five histogram features (mean, variance, skewness, kurtosis, and entropy1) and five gray level co-occurrence matrix features (GLCM; angular second moment (ASM), entropy2, contrast, correlation, and inverse difference moment (IDM)) were extracted. The texture parameters were statistically analyzed to identify the differences between the two groups, and the potential predictive parameters to differentiate the responding group from the non-responding group were subsequently tested using multivariable logistic regression analysis.
RESULTS: A total of 107 responding and 86 non-responding lesions were evaluated. A higher variance, entropy1, contrast, entropy2 and a lower ASM, correlation, IDM were independently (P < 0.05) associated with a good response to chemotherapy with the areas under the ROC curves (AUCs) of 0.602-0.784. Variance (P < 0.001) and ASM (P = 0.001) remained potential predictive values to discriminate responding lesions from non-responding lesions when tested using multivariable logistic regression analysis. The highest AUC of the predictors from the association of variance and ASM was 0.814.
CONCLUSION: MR texture features on pre-treated T2 images have the potential to predict the therapeutic response of colorectal liver metastases.
引用
- Zhang H, Li W, Hu F, et al. MR texture analysis: potential imaging biomarker for predicting the chemotherapeutic response of patients with colorectal liver metastases. Abdom Radiol (NY). 2019. PMID: 29967982. doi:10.1007/s00261-018-1682-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。