大鼠脂肪肝异质性的双能CT多参数定量分析评估
研究采用快速kVp切换双能CT(rsDECT)对大鼠脂肪肝异质性进行多参数定量分析,24只雄性大鼠随机分为实验组(n=16)和对照组(n=8),自第8周起每3周检查4只实验组和2只对照组大鼠。结果显示左肝叶各参数与病理脂肪百分比的相关性优于右肝叶,左肝叶ROC曲线下面积也大于右肝叶,rsDECT多参数成像可定量评估肝脏脂肪沉积的异质性。
要点
- 左肝叶rsDECT参数与病理脂肪百分比的相关性优于右肝叶。
- 左肝叶的ROC曲线下面积大于右肝叶。
- 左肝叶脂肪百分比显著高于右肝叶,而(L/S)70 keV和(L-S)70 keV显著低于右肝叶。
核心结论
- rsDECT多参数成像可定量评估大鼠肝脏脂肪沉积的异质性,为准确有效评估脂肪肝异质性提供有价值的信息。
研究设计与样本
- 动物实验,24只雄性大鼠随机分为实验组(n=16)和对照组(n=8),自第8周起每3周对4只实验组和2只对照组大鼠行rsDECT检查,以病理分析脂肪百分比为参考标准。
诊断标准与关键数值
- 不同脂肪肝组间(L/S)70 keV、(L-S)70 keV、Slope和LFC均存在显著差异(p < 0.05);左右肝叶rsDECT结果与病理脂肪百分比相关(p < 0.05),左肝叶相关性更好;左肝叶ROC曲线下面积大于右肝叶。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: To investigate the value of using rapid kVp switching dual energy computed tomography (rsDECT) for the multi-parameter analysis of the heterogeneity of fatty liver in rat.
MATERIALS AND METHODS: Twenty-four male rats were randomly divided into experimental (n = 16) and control (n = 8) groups. Four rats in the experimental group and two in the control group were examined by rsDECT every 3 weeks starting from week 8. The liver fat contents (LFC) of the left and right liver lobes were measured on the fat(water)-based material decomposition images to calculate fat content and CT value of liver and spleen were measured on the 70keV monochromatic images to calculate the liver-to-spleen CT value ratio [(L/S)70 keV] and difference at 70keV[(L-S)70 keV], and the spectral curve slopes of the left and right liver lobes (Slope-L, Slope-R). Measurements were evaluated statistically.
RESULTS: The statistical analysis showed that the (L/S)70 keV, (L-S)70 keV, Slope and LFC in the different fatty liver groups were all significantly different (p < 0.05). Pearson correlation analysis results showed that the rsDECT results of the left and right liver lobes correlated with the fat percentage from pathological analysis (p < 0.05), with the left liver lobe having better correlation. Paired t-tests showed that the fat percentage of the left liver lobe was significantly higher than that of the right one, while (L/S)70 keV, and (L-S)70 keV were significantly lower. Diagnostic analysis using ROC curve showed that the areas under the curves with parameters of the left liver lobe were also greater than those of the right liver lobe.
CONCLUSION: rsDECT multi-parameter imaging could quantitatively evaluate the heterogeneity of fat deposition in the liver, providing valuable information for the accurate and effective assessment of the heterogeneity of fatty liver.
引用
- Cao Q, Shang S, Han X, et al. Evaluation on Heterogeneity of Fatty Liver in Rats: A Multiparameter Quantitative Analysis by Dual Energy CT. Acad Radiol. 2018. PMID: 30041922. doi:10.1016/j.acra.2018.05.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。