文献速递腹部外周血管技术与安全CT

光谱CT最佳单能成像可能提高肝血管成像质量

Optimal Monochromatic Imaging of Spectral Computed Tomography Potentially Improves the Quality of Hepatic Vascular Imaging.
PubMed 文献 · Korean J Radiol · 2018-06-14

回顾性分析35例腹部CT血管造影数据,比较混合能量(QC)、70 keV与最佳单能模式下肝动脉、门静脉和肝静脉的CT值、噪声、CNR、SNR及主观评分。最佳单能值范围为49–53 keV(平均51 keV),各血管的客观参数和主观评分均显著优于70 keV和QC图像(p < 0.001)。

要点

  • 肝血管最佳单能值范围为49–53 keV(平均51 keV),可用于优化显示。
  • 最佳单能图像下肝总动脉、门静脉、肝静脉的CNR和主观评分均优于70 keV和QC图像。
  • 与混合能量(QC)和70 keV数据集相比,最佳单能成像可改善肝血管成像参数和图像质量。

核心结论

  • 与常规混合kV和70 keV数据集相比,最佳单能图像可改善肝总动脉、肝门静脉和肝静脉的成像参数并优化图像质量。

研究设计与样本

  • 回顾性分析35例腹部CT血管造影患者的影像数据,肝动脉、门静脉和肝静脉分别重建为混合能量(QC)、70 keV和最佳单能模式,比较CT值、图像噪声、CNR、SNR及主观定性分析。

诊断标准与关键数值

  • 评估肝总动脉、门静脉和肝静脉的最佳单能值范围为49–53 keV,平均51 keV;肝总动脉CNR在最佳单能、70 keV和QC组分别为24.6 ± 10.9、18.1 ± 8.3、11.6 ± 4.6(p < 0.001),主观评分分别为4.7 ± 0.2、4.0 ± 0.3、3.6 ± 0.4(p < 0.001);肝门静脉CNR分别为6.9 ± 2.7、4.3 ± 1.9、3.0 ± 2.1(p < 0.001),主观评分分别为4.5 ± 0.3、3.9 ± 0.4、3.3 ± 0.3(p < 0.001);肝静脉CNR分别为5.7 ± 2.3、4.2 ± 1.9、2.7 ± 1.4,主观评分分别为4.3 ± 0.3、3.8 ± 0.4、3.2 ± 0.3(p < 0.001)。

临床应用与阅片要点

  • 阅片及报告时可参考肝血管最佳单能值为49–53 keV(平均51 keV),该范围内图像CNR和主观评分均优于70 keV和混合能量(QC)图像。

局限性

  • 本文为回顾性分析。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the efficiency of spectral computed tomography (CT) optimal monochromatic images in improving imaging quality of liver vessels.

MATERIALS AND METHODS: The imaging data of 35 patients with abdominal CT angiography were retrospectively analyzed. Hepatic arteries, portal veins, and hepatic veins were reconstructed with mixed energy (quality check, QC), 70 keV and optimal monochromatic mode. Comparative parameters were analyzed including CT value, image noise (IN), contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), and subjective qualitative analysis.

RESULTS: The optimal monochromatic value for assessment of the common hepatic artery, portal vein, and hepatic vein ranged between 49 keV and 53 keV, with a mean of 51 keV. There were statistically significant differences (p < 0.001) among the optimal monochromatic, 70 keV and QC images with regards to the hepatic vascular CT value, IN, CNR, SNR, and subjective qualitative score. CNR of the common hepatic artery in the optimal monochromatic, 70 keV and QC groups was 24.6 ± 10.9, 18.1 ± 8.3, and 11.6 ± 4.6, respectively (p < 0.001) with subjective scores of 4.7 ± 0.2, 4.0 ± 0.3, and 3.6 ± 0.4, respectively (p < 0.001). CNR of the hepatic portal vein was 6.9 ± 2.7, 4.3 ± 1.9, and 3.0 ± 2.1, respectively (p < 0.001) with subjective scores of 4.5 ± 0.3, 3.9 ± 0.4, and 3.3 ± 0.3, respectively (p < 0.001). CNR of the hepatic vein was 5.7 ± 2.3, 4.2 ± 1.9, and 2.7 ± 1.4, respectively with subjective scores of 4.3 ± 0.3, 3.8 ± 0.4, and 3.2 ± 0.3, respectively (p < 0.001).

CONCLUSION: Optimal monochromatic images can lead to improvement in the imaging parameters and optimization of the image quality of the common hepatic artery, hepatic portal vein and hepatic vein compared with conventional mixed kV and with 70 keV datasets.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Yin XP, Gao BL, Li CY, et al. Optimal Monochromatic Imaging of Spectral Computed Tomography Potentially Improves the Quality of Hepatic Vascular Imaging. Korean J Radiol. 2018. PMID: 29962864. doi:10.3348/kjr.2018.19.4.578

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。