文献速递腹部泌尿生殖MR

化学位移成像评估肾上腺肿块:系统综述与荟萃分析

Chemical shift imaging for evaluation of adrenal masses: a systematic review and meta-analysis.
PubMed 文献 · Eur Radiol · 2018-07-16

该系统综述与荟萃分析纳入18项研究、1138例患者共1280个病灶(859个腺瘤、421个非腺瘤),评估化学位移成像鉴别肾上腺腺瘤与非腺瘤的效能。汇总敏感度0.94(95%CI 0.88-0.97),特异度0.95(95%CI 0.89-0.97),SROC曲线AUC为0.98(95%CI 0.96-0.99),视觉评估与定量指标诊断准确性相近。

要点

  • 化学位移成像鉴别肾上腺腺瘤的汇总敏感度0.94、特异度0.95、AUC 0.98。
  • 视觉评估AUC 0.95,与信号强度指数(0.98)和肾上腺/脾比值(0.99)接近。
  • 使用定量指标并未在视觉评估基础上进一步提高诊断准确性。

核心结论

  • 化学位移成像对肾上腺腺瘤具有高敏感度、高特异度和高准确性,使用定量指标并未提高诊断效能。

研究设计与样本

  • 系统综述与荟萃分析,检索MEDLINE、Web of Science核心合集、EMBASE和Cochrane对照试验中心注册库,纳入18项研究、1138例患者、1280个病灶(859个腺瘤、421个非腺瘤),采用QUADAS-2工具评价方法学质量,使用双变量随机效应模型计算汇总敏感度、特异度及SROC曲线。

诊断标准与关键数值

  • 化学位移成像鉴别肾上腺腺瘤的汇总敏感度0.94(95%CI 0.88-0.97)、汇总特异度0.95(95%CI 0.89-0.97)、SROC曲线AUC 0.98(95%CI 0.96-0.99);信号强度指数(978个病灶,14项研究)AUC 0.98,肾上腺/脾比值(394个病灶,7项研究)AUC 0.99,视觉评估(560个病灶,5项研究)AUC 0.95。

临床应用与阅片要点

  • 作者结论认为,将化学位移成像纳入腹部MRI方案可为MR检查中发现的肾上腺肿块分类提供有效解决方案;视觉评估肾上腺化学位移成像已足够,使用定量指标并不提高诊断准确性。

局限性

  • 基于诊断比值比(DOR)的异质性分析显示存在相当大的异质性,不一致指数I²为94%。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To perform a systematic review and meta-analysis of published data to evaluate the utility of chemical shift imaging (CSI) for differentiating between adrenal adenomas and non-adenomas.

METHODS: A systematic search of the MEDLINE, Web of Science Core Collection, EMBASE and Cochrane Central Register of Controlled Trials electronic databases was performed. The methodological quality of the included studies was assessed by using the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies) tool. A bivariate random effect model was used to determine summary and subgroup sensitivity and specificity and calculate summary receiver operating characteristic curves (SROC).

RESULTS: Eighteen studies with 1138 patients and 1280 lesions (859 adenomas, 421 non-adenomas) in total were included. In addition to summary analysis, quantitative analyses of the adrenal signal intensity index (SII, 978 lesions, 14 studies), adrenal-to-spleen ratio (ASR; 394 lesions, 7 studies) and visual analysis (560 lesions, 5 studies) were performed. The resultant data showed considerable heterogeneity (inconsistency index I2 of 94%, based on the diagnostic odds ratio, DOR). The pooled sensitivity of CSI for adenoma was 0.94 [95% confidence interval (CI) 0.88-0.97] and pooled specificity was 0.95 (95% CI 0.89-0.97). The area (AUC) under the SROC curve was 0.98 (95% CI 0.96-0.99). The corresponding AUCs were 0.98, 0.99 and 0.95 for SII, ASR and visual evaluation, respectively.

CONCLUSION: CSI has high sensitivity, specificity and accuracy for adrenal adenoma. Diagnostic performance does not improve when quantitative indices are used.

KEY POINTS: • Inclusion of CSI in abdominal MRI protocols provides an effective solution for classifying adrenal masses discovered on MR exams • Visual evaluation of adrenal CSI is sufficient; use of quantitative indices does not improve diagnostic accuracy.

来源:Eur Radiol,查看原文。版权归原作者所有。