文献速递介入技术与安全US

轻度防腐尸体作为介入放射学常用超声引导操作的培训工具

Lightly Embalmed Cadavers as a Training Tool for Ultrasound-Guided Procedures Commonly Used in Interventional Radiology.
PubMed 文献 · Acad Radiol · 2018-07-17

该文介绍使用轻度防腐尸体模拟介入放射学常见超声引导操作(肝活检、肾活检、胸腔穿刺和血管穿刺)的可行性。尸体可摆为仰卧、俯卧和坐位,医学生和放射科住院医师成功完成操作,组织层次触感真实,模拟图像与活体患者预期图像相似。作者认为这是一种创新且可行的真实感训练工具。

要点

  • 轻度防腐尸体可摆为仰卧、俯卧和直立坐位,支持完整操作模拟。
  • 医学生和放射科住院医师成功完成肝活检、肾活检、胸腔穿刺和血管穿刺。
  • 组织层次触感为进针或扩张组织提供真实反馈,模拟图像与活体预期图像相似。

核心结论

  • 轻度防腐尸体是创新且可行的工具,能以真实方式模拟介入放射学常见超声引导操作,供首次接触患者前进行刻意练习。

研究设计与样本

  • 描述性可行性研究,使用轻度防腐尸体模拟介入放射学常见超声引导操作,包括肝活检、肾活检、胸腔穿刺和血管穿刺;未报告样本量、中心数和参考标准。

临床应用与阅片要点

  • 作者认为轻度防腐尸体可在首次接触患者前用于介入放射学常见超声引导操作的真实感刻意练习。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Competency in ultrasound (US) imaging and US-guided procedures is often difficult for medical students and residents to master. The use of simulation training has been strongly encouraged but the quality of phantom models available for US-guided procedures is limited. As a feasible alternative, we describe the innovative use of a lightly embalmed cadaver for realistic practice of common interventional radiology (IR) procedures prior to direct patient care.

MATERIALS AND METHODS: Lightly embalmed cadavers were positioned as patients would be in the IR suite: supine, prone, and erect seated position. Lidocaine was injected and visualized under standard percutaneous techniques and sonographic guidance was used to simulate common US-guided procedures performed in IR including liver biopsy, kidney biopsy, thoracentesis, and vascular access.

RESULTS: The ability to position cadavers was a key factor that allowed entire procedures to be simulated. Medical students with very limited exposure to US imaging and diagnostic radiology residents with minimal exposure to US imaging successfully completed common US-guided procedures. Arterial and venous vascular access was obtained. Wires were passed and catheters easily placed via both access sites. The texture of the tissue layers provided realistic feedback for the trainees as they advanced the needle or dilated the tissues. Images from each simulated procedure resembled images expected in a living patient.

CONCLUSION: Lightly embalmed cadavers are an innovative and feasible tool to simulate common IR US-guided procedures in a realistic fashion for deliberate practice in advance of first-attempt encounters with patients.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Meek MEM, Meek JC, Hollowoa B, et al. Lightly Embalmed Cadavers as a Training Tool for Ultrasound-Guided Procedures Commonly Used in Interventional Radiology. Acad Radiol. 2018. PMID: 30017501. doi:10.1016/j.acra.2018.05.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。