基于变分网络的深度学习重建用于可变密度单次激发快速自旋回波MRI

Variable-Density Single-Shot Fast Spin-Echo MRI with Deep Learning Reconstruction by Using Variational Networks.
PubMed 文献 · Radiology · 2018-07-24

在3.0 T设备上对157例腹部成像患者行冠状位可变密度单次激发快速自旋回波序列(3.25倍加速),用130例训练变分网络、27例评估。与并行成像联合压缩感知重建相比,变分网络重建的总体图像质量更优(P=0.02),感知信噪比(P=0.01)和锐利度(P<0.001)改善,对比度和残余伪影无差异。重建时间由每层5.60秒±1.30缩短至0.19秒±0.04。

要点

  • 变分网络重建较并行成像联合压缩感知重建总体图像质量更优(P=0.02)。
  • 变分网络重建的感知信噪比(P=0.01)和锐利度(P<0.001)改善。
  • 变分网络重建每层时间0.19秒±0.04,并行成像联合压缩感知为5.60秒±1.30。

核心结论

  • 与常规并行成像联合压缩感知重建相比,变分网络方法加速了可变密度单次激发快速自旋回波序列的重建,并取得更优的总体图像质量、更高的感知信噪比和锐利度。

研究设计与样本

  • 方法学研究,157例腹部成像患者(男72例、女85例;平均年龄11岁,范围1-34岁),2016年3月至2017年4月在3.0 T设备上行冠状位可变密度单次激发快速自旋回波序列,加速倍数3.25;130例用于训练变分网络(基于并行成像联合压缩感知重建),27例用于评估;由三名放射科医师独立盲法评分。

诊断标准与关键数值

  • 图像质量由三名放射科医师盲法评分,包括总体图像质量、感知信噪比、图像对比度、锐利度和残余伪影,评分范围1分(不可诊断)至5分(优秀);变分网络与并行成像联合压缩感知重建比较:感知信噪比P=0.01、锐利度P<0.001、总体图像质量P=0.02、图像对比度P=0.24、残余伪影P=0.07。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To develop a deep learning reconstruction approach to improve the reconstruction speed and quality of highly undersampled variable-density single-shot fast spin-echo imaging by using a variational network (VN), and to clinically evaluate the feasibility of this approach. Materials and Methods Imaging was performed with a 3.0-T imager with a coronal variable-density single-shot fast spin-echo sequence at 3.25 times acceleration in 157 patients referred for abdominal imaging (mean age, 11 years; range, 1-34 years; 72 males [mean age, 10 years; range, 1-26 years] and 85 females [mean age, 12 years; range, 1-34 years]) between March 2016 and April 2017. A VN was trained based on the parallel imaging and compressed sensing (PICS) reconstruction of 130 patients. The remaining 27 patients were used for evaluation. Image quality was evaluated in an independent blinded fashion by three radiologists in terms of overall image quality, perceived signal-to-noise ratio, image contrast, sharpness, and residual artifacts with scores ranging from 1 (nondiagnostic) to 5 (excellent). Wilcoxon tests were performed to test the hypothesis that there was no significant difference between VN and PICS. Results VN achieved improved perceived signal-to-noise ratio (P = .01) and improved sharpness (P < .001), with no difference in image contrast (P = .24) and residual artifacts (P = .07). In terms of overall image quality, VN performed better than did PICS (P = .02). Average reconstruction time ± standard deviation was 5.60 seconds ± 1.30 per section for PICS and 0.19 second ± 0.04 per section for VN. Conclusion Compared with the conventional parallel imaging and compressed sensing reconstruction (PICS), the variational network (VN) approach accelerates the reconstruction of variable-density single-shot fast spin-echo sequences and achieves improved overall image quality with higher perceived signal-to-noise ratio and sharpness. © RSNA, 2018 Online supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。