文献速递心血管外周血管CTDSA

采用宽体探测器第三代扫描仪行TAVI术前CT血管成像:可行性、肾脏安全性和冠状动脉树诊断准确性

CT angiography prior to TAVI procedure using third-generation scanner with wide volume coverage: feasibility, renal safety and diagnostic accuracy for coronary tree.
PubMed 文献 · Br J Radiol · 2018-07-24

研究纳入115例连续TAVI患者,使用第三代宽体CT扫描仪和50 ml对比剂行术前CT成像,评估图像质量、冠状动脉树诊断准确性(与有创冠状动脉造影对照)及肾脏安全性。结果显示图像质量良好,冠状动脉评估敏感度97%、特异度85%、准确率88%,血肌酐术前与术后72小时无显著变化。

要点

  • 第三代宽体CT联合50 ml对比剂方案行TAVI术前评估可行,图像质量中位评分>3分。
  • 与有创冠状动脉造影对照,CT冠状动脉评估敏感度97%、特异度85%、准确率88%。
  • 术前与术后72小时血肌酐分别为1.21±0.52与1.22±0.49 mg/dl,未见显著变化。

核心结论

  • 低对比剂用量CT可行且临床有用,能实现精确的TAVI术前规划并准确评估冠状动脉树。

研究设计与样本

  • 连续纳入115例TAVI患者(51例女性,平均年龄82.5±6.2岁,平均BMI 26.7±3.6),采用第三代宽体CT扫描仪联合扫描方案,对比剂总量50 ml。

关键影像表现/征象

  • 主动脉根部、升/降主动脉、肾下主动脉、右/左股总动脉水平平均CNR分别为14.8±2.3、15.7±1.7、14.9±3.1、15.8±4.7、20.3±9.9、20.8±6.9。
  • 图像质量采用4分视觉量表(4-1)评估,中位质量评分>3分。
  • 仅1例患者出现中度瓣周反流。

诊断标准与关键数值

  • 以有创冠状动脉造影为参考,CT冠状动脉树按节段分析敏感度97%、特异度85%、阴性预测值99%、阳性预测值62%、准确率88%。
  • 主动脉瓣环测量与最终手术结果进行比较。

临床应用与阅片要点

  • 本方案使用50 ml对比剂即可完成TAVI术前主动脉和冠状动脉评估,图像质量良好且冠状动脉诊断准确性高,术后72小时血肌酐未见显著变化。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE:: To evaluate feasibility, image quality and accuracy of a reduced contrast volume protocol for pre-procedural CT imaging in transcatheter aortic valve implantation (TAVI) using a third generation wide array CT scanner.

METHODS:: 115 consecutive patients (51F, mean age 82.5 ± 6.2 y, mean BMI 26.7 ± 3.6) referred for TAVI were examined with wide-array CT scanner with a combined scan protocol and a total amount of 50 ml contrast agent. A 4-point visual scale (4-1) was used to assess image quality . Contrast attenuation values (HU) and contrast-to-noise ratio (CNR) were measured at the level of the aortic root, ascending/descending aorta, subrenal aorta and at the level of right and left common femoral arteries. Coronary tree was assessed and compared with invasive coronary angiography (ICA). Aortic annulus measurements were compared with final procedural results. Patients creatinine was monitored at the baseline and 72 h after procedure.

RESULTS:: Median quality score value was >3. Mean CNR at the level of the aortic root, ascending/descending aorta, subrenal aorta and at the level of right and left common femoral arteries were 14.8 ± 2.3, 15.7 ± 1.7, 14.9 ± 3.1, 15.8 ± 4.7, 20.3 ± 9.9, 20.8 ± 6.9 respectively. Only 1 patient had moderate paravalvular regurgitation. In comparison with ICA for coronary assessment CTA showed in a segment based analysis sensitivity, specificity, negative predictive value, positive predictive value and accuracy of 97, 85, 99,62 and 88% respectively. Mean creatinine before CT and 72 h after procedure were 1.21 ± 0.52 and1.22 ± 0.49 mg dl-1. Mean DLP was 442.4 ± 21.2 mGy/cm.

CONCLUSION:: CT with low contrast volume is feasible and clinically useful, allowing precise pre-procedural TAVI planning with accurate assessment of coronary tree.

ADVANCES IN KNOWLEDGE:: third generation CT scanner with whole heart coverage allows examinations for assessment of aorta and coronary arteries in TAVI planning using low dose of contrast medium maintaining good quality and high diagnostic accuracy.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Annoni AD, Andreini D, Pontone G, et al. CT angiography prior to TAVI procedure using third-generation scanner with wide volume coverage: feasibility, renal safety and diagnostic accuracy for coronary tree. Br J Radiol. 2018. PMID: 30004788. doi:10.1259/bjr.20180196

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。