文献速递心血管胸部CTDRUS

心脏导线穿孔评估:胸部X线摄影、经胸超声心动图与心电门控增强心脏CT的比较

Assessment of Cardiac Lead Perforation: Comparison Among Chest Radiography, Transthoracic Echocardiography and Electrocardiography-gated Contrast-enhanced Cardiac CT.
PubMed 文献 · Eur Radiol · 2018-07-17

该回顾性研究纳入2010年5月至2017年10月共52例临床疑似心脏导线穿孔患者,其中13例确诊,比较胸部X线摄影、经胸超声心动图与心电门控增强心脏CT的诊断效能,以手术、电生理结果及临床随访为复合参考标准,结果显示心电门控增强心脏CT准确率98.1%,AUROC高于胸部X线摄影(p<0.001)和经胸超声心动图(p<0.001)。

要点

  • 心电门控增强心脏CT诊断心脏导线穿孔准确率98.1%,高于胸部X线摄影的73.1%和经胸超声心动图的82.7%。
  • 心电门控增强心脏CT的AUROC高于胸部X线摄影(p<0.001)和经胸超声心动图(p<0.001)。
  • 心电门控增强心脏CT在心脏导线穿孔评估中优于胸部X线摄影和经胸超声心动图。

核心结论

  • 心电门控增强心脏CT在心脏导线穿孔评估中优于胸部X线摄影和经胸超声心动图。

研究设计与样本

  • 回顾性研究,经中山大学孙逸仙纪念医院(中国广州)伦理审查委员会批准,豁免知情同意。
  • 2010年5月至2017年10月纳入52例临床疑似心脏导线穿孔并接受胸部X线摄影、经胸超声心动图及心电门控增强心脏CT的患者,其中13例确诊心脏导线穿孔。
  • 以手术和电生理结果及临床随访组成的复合参考标准评估三种检查的诊断效能,采用ROC曲线,AUROC比较采用McNemar检验。

诊断标准与关键数值

  • 胸部X线摄影诊断心脏导线穿孔准确率为73.1%。
  • 经胸超声心动图诊断心脏导线穿孔准确率为82.7%。
  • 心电门控增强心脏CT诊断心脏导线穿孔准确率为98.1%。
  • 心电门控增强心脏CT的AUROC高于胸部X线摄影(p<0.001)和经胸超声心动图(p<0.001)。

临床应用与阅片要点

  • 原文结论认为心电门控增强心脏CT在心脏导线穿孔评估中优于胸部X线摄影和经胸超声心动图。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Cardiac lead perforation is a rare but potentially life-threatening event. The purpose of this study was to investigate the diagnostic performances of chest radiography, transthoracic echocardiography (TTE) and electrocardiography (ECG)-gated contrast-enhanced cardiac CT in the assessment of cardiac lead perforation.

METHODS: This retrospective study was approved by the ethics review board of Sun Yat-Sen Memorial Hospital at Sun Yat-Sen University (Guangzhou, China), and the need to obtain informed consent was waived. Between May 2010 and Oct 2017, 52 patients were clinically suspected to have a cardiac lead perforation and received chest radiography, TTE and ECG-gated contrast-enhanced cardiac CT. Among them, 13 patients were identified as having cardiac lead perforation. The diagnostic performances of these three modalities were evaluated by receiver-operating characteristic (ROC) curves using a composite reference standard of surgical and electrophysiological results and clinical follow-up. The areas under ROCs (AUROCs) were compared with the McNemar test.

RESULTS: The accuracies of chest radiography, TTE and ECG-gated contrast-enhanced cardiac CT imaging for the diagnosis of cardiac lead perforation were 73.1%, 82.7% and 98.1%, respectively. ECG-gated contrast-enhanced cardiac CT had a higher AUROC than chest radiography (p < 0.001) and TTE (p < 0.001).

CONCLUSIONS: ECG-gated contrast-enhanced cardiac CT is superior to both chest radiography and TTE imaging for the assessment of cardiac lead perforation.

KEY POINTS: • ECG-gated contrast-enhanced cardiac CT has an accuracy of 98.1% in the diagnosis of cardiac lead perforation. • The AUROC of ECG-gated contrast-enhanced cardiac CT is higher than those of chest radiography and TTE imaging. • ECG-gated contrast-enhanced cardiac CT imaging has better diagnostic performance than both chest radiography and TTE imaging for the assessment of cardiac lead perforation.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Zhang X, Zheng C, Wang P, et al. Assessment of Cardiac Lead Perforation: Comparison Among Chest Radiography, Transthoracic Echocardiography and Electrocardiography-gated Contrast-enhanced Cardiac CT. Eur Radiol. 2018. PMID: 30019144. doi:10.1007/s00330-018-5633-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。