文献速递心血管CTMR

心肌延迟强化CT评估心力衰竭:与MRI的比较

Myocardial Delayed Enhancement CT for the Evaluation of Heart Failure: Comparison to MRI.
PubMed 文献 · Radiology · 2018-07-10

研究纳入44例心力衰竭患者,回顾性分析双能CT心肌延迟强化(MDE)与钆延迟强化(LGE)MRI,以MRI为参考标准。碘密度图检出MDE的敏感度92%、特异度98%,AUC为0.97,读者间一致性κ=0.82,结论为MDE CT能准确检出和定位心肌瘢痕。

要点

  • 碘密度图检出MDE敏感度92%(195/213节段)、特异度98%(481/491节段)。
  • 碘密度图AUC 0.97,40-keV虚拟单能图AUC 0.95(P<.001)。
  • 读者间一致性碘密度图κ=0.82,40-keV虚拟单能图κ=0.72。

核心结论

  • 以LGE MRI为参考标准,心肌延迟强化CT能准确检出和定位心力衰竭患者的心肌瘢痕。

研究设计与样本

  • 回顾性分析2013年至2016年间44例心力衰竭患者(30例男性,平均年龄66岁±14)的MDE CT与LGE MRI图像,以LGE MRI为参考标准。
  • 由两名独立读者评估碘密度图和虚拟单能图上的MDE有无及模式,并测量CNR和相对正常心肌的信号强度增加百分比。

关键影像表现/征象

  • 44例中35例(80%)可见局灶性LGE,其中非缺血型22例(50%)、缺血型13例(30%)。
  • 碘密度图在CT图像中CNR和信号强度增加百分比最高(P<.05)。

诊断标准与关键数值

  • 碘密度图检出任何MDE CT异常的敏感度92%(195/213节段)、特异度98%(481/491节段)。
  • 碘密度图检出MDE的AUC为0.97,40-keV虚拟单能图为0.95(P<.001)。
  • 读者间一致性κ值:碘密度图0.82,40-keV虚拟单能图0.72。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To assess the diagnostic performance of dual-energy CT with myocardial delayed enhancement (MDE) in the detection and classification of myocardial scar in patients with heart failure, with late gadolinium enhancement (LGE) MRI as the standard of reference. Materials and Methods MDE CT and LGE MRI were performed in 44 patients with heart failure (30 men; mean patient age, 66 years ± 14) between 2013 and 2016, and images were retrospectively analyzed. The presence and patterns of MDE on iodine-density and virtual monochromatic (VM) images were assessed by two independent readers. Contrast-to-noise ratio (CNR) and percentage signal intensity increase relative to normal myocardium were measured. Diagnostic performance and area under the receiver operating characteristic curve for MDE CT and kappa values for reader agreement were determined. Results Thirty-five of the 44 patients (80%) demonstrated a focal area of LGE, with a nonischemic pattern in 22 of the 44 patients (50%) and an ischemic pattern in 13 (30%). Iodine-density images demonstrated the highest CNR and percentage signal intensity increase on CT images (P < .05), resulting in the highest diagnostic performance in the detection of any MDE CT abnormality (92% sensitivity [195 of 213 segments] and 98% specificity [481 of 491 segments]). The areas under the receiver operating characteristic curve for iodine-density images and 40-keV VM images in the detection of MDE were 0.97 and 0.95, respectively (P < .001). Kappa values for reader agreement were 0.82 for iodine-density images and 0.72 for 40-keV VM images. Conclusion Myocardial delayed enhancement CT enables accurate detection and localization of scar in patients with heart failure when compared with late gadolinium enhancement MRI, the reference standard.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Ohta Y, Kitao S, Yunaga H, et al. Myocardial Delayed Enhancement CT for the Evaluation of Heart Failure: Comparison to MRI. Radiology. 2018. PMID: 29989514. doi:10.1148/radiol.2018172523

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。