文献速递胸部技术与安全CT

光谱CT虚拟单色图像减少胸部对比剂所致线束硬化伪影的最佳能量水平

The Optimal Energy Level of Virtual Monochromatic Images From Spectral CT for Reducing Beam-Hardening Artifacts Due to Contrast Media in the Thorax.
PubMed 文献 · AJR Am J Roentgenol · 2018-07-05

本研究回顾性纳入101例胸部增强CT患者,比较70–200 keV虚拟单色图像与常规多色图像,发现130 keV虚拟单色图像主观图像质量最佳且噪声显著更低,100与130 keV的CT衰减差异显著低于常规图像,结论认为100与130 keV是胸部CT评估的最佳能量水平。

要点

  • 130 keV虚拟单色图像的主观图像质量评分最佳,且图像噪声显著低于常规多色图像。
  • 100与130 keV虚拟单色图像的CT衰减差异均显著低于常规多色图像。
  • SNR与CNR随能量水平升高而降低,130 keV的SNR与常规多色图像相似。

核心结论

  • 虚拟单色成像可减少线束硬化伪影并改善图像质量,胸部CT评估在100与130 keV时最佳。

研究设计与样本

  • 回顾性研究纳入101例连续胸部增强CT患者,全组采用相同对比剂与注射方案,获取70–200 keV虚拟单色图像与常规多色图像,由读者对常规多色及70、100、130、200 keV虚拟单色图像进行主观图像质量评分。

关键影像表现/征象

  • 130 keV虚拟单色图像的主观图像质量评分最佳。
  • 130 keV虚拟单色图像的图像噪声显著低于常规多色图像(所有p < 0.001)。
  • 100与130 keV虚拟单色图像的CT衰减差异均显著低于常规多色图像(所有p < 0.001)。
  • 100 keV虚拟单色图像的CT衰减差异最低,但与130 keV虚拟单色图像间无显著差异。
  • SNR与CNR随能量水平升高而降低,130 keV虚拟单色图像的SNR与常规多色图像相似。

诊断标准与关键数值

  • 主观图像质量评分在常规多色图像及70、100、130、200 keV虚拟单色图像间比较,130 keV评分最佳。
  • 图像噪声在130 keV虚拟单色图像显著低于常规多色图像(p < 0.001)。
  • CT衰减差异在100与130 keV虚拟单色图像均显著低于常规多色图像(p < 0.001),100 keV最低但与130 keV无显著差异。
  • SNR在130 keV虚拟单色图像与常规多色图像间相似,SNR与CNR均随能量水平升高而降低。

临床应用与阅片要点

  • 胸部增强CT评估对比剂所致线束硬化伪影时,可参考100与130 keV虚拟单色图像。
  • 130 keV虚拟单色图像主观质量最佳且噪声显著低于常规多色图像。
  • SNR与CNR随能量水平升高而降低,130 keV的SNR与常规多色图像相似。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The purpose of this study is to determine the optimal energy level of virtual monochromatic images from spectral CT compared with conventional polychromatic images for reducing beam-hardening artifacts caused by contrast media in the thorax.

MATERIALS AND METHODS: A total of 101 consecutive patients who underwent chest CT with contrast enhancement were retrospectively included in this study. The same contrast media and injection protocols were applied to the whole study population. Virtual monochromatic image datasets ranging from 70 to 200 keV and conventional polychromatic images were obtained. Readers' subjective image quality scores were recorded for conventional polychromatic and virtual monochromatic images obtained at 70, 100, 130, and 200 keV. Image noise, CT attenuation difference, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) were also obtained in each algorithm. Comparisons of parameters between algorithms were performed.

RESULTS: The best subjective image quality score and significantly lower image noise were observed for 130-keV virtual monochromatic images compared with conventional polychromatic images (all p < 0.001). Also, CT attenuation differences were significantly lower for both 100- and 130-keV virtual monochromatic images than for conventional polychromatic images (all p < 0.001). Meanwhile, the lowest differences in CT attenuation were observed for 100-keV virtual monochromatic images compared with conventional polychromatic images. However, there were no significant differences in CT attenuation between 100- and 130-keV virtual monochromatic images. SNR was similar between 130-keV virtual monochromatic images and conventional polychromatic images, although both SNR and CNR decreased as the energy level increased.

CONCLUSION: Virtual monochromatic imaging reduced beam-hardening artifacts and improved image quality, and optimal evaluation of chest CT was best achieved at 100 and 130 keV.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Kim C, Kim D, Lee KY, et al. The Optimal Energy Level of Virtual Monochromatic Images From Spectral CT for Reducing Beam-Hardening Artifacts Due to Contrast Media in the Thorax. AJR Am J Roentgenol. 2018. PMID: 29975117. doi:10.2214/AJR.17.19377

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。