文献速递胸部CT

新型基于模型迭代重建算法在低剂量胸部CT气道树定量分析中的应用:与常规剂量CT自适应统计迭代重建的比较

Quantitative Analysis of Airway Tree in Low-dose Chest CT with a New Model-based Iterative Reconstruction Algorithm: Comparison to Adaptive Statistical Iterative Reconstruction in Routine-dose CT.
PubMed 文献 · Acad Radiol · 2018-07-13

研究纳入30例同时行常规剂量(噪声指数14 HU)和低剂量(30%水平,噪声指数28 HU)胸部CT的患者,低剂量图像分别用ASIR、MBIRSTND和MBIRRP20重建,常规剂量用ASIR重建,用CAD软件测量右中叶支气管尺寸。低剂量CT较常规剂量降低70.76%剂量(0.88±0.83 mSv vs 3.01±1.89 mSv),MBIRSTND和MBIRRP20在支气管长度测量、测量变异性及支气管壁连续性和完整性方面优于常规剂量ASIR(P<.05)。

要点

  • 低剂量CT在30%辐射剂量水平下,MBIRSTND和MBIRRP20的气道定量测量优于常规剂量ASIR(P<.05)。
  • MBIRSTND在主观噪声方面更优,MBIRRP20在显示远端分支方面更优。
  • 低剂量CT较常规剂量CT降低70.76%辐射剂量(0.88±0.83 mSv vs 3.01±1.89 mSv)。

核心结论

  • MBIRSTND和MBIRRP20算法在30%辐射剂量下提供优于常规剂量CT ASIR的气道定量分析。

研究设计与样本

  • 纳入30例因肺部疾病同时行常规剂量(噪声指数14 HU)和低剂量(30%水平,噪声指数28 HU)胸部CT检查的患者,管电压120 kVp,自动管电流调制;常规剂量用ASIR重建,低剂量用ASIR、MBIRSTND和MBIRRP20重建,用CAD软件测量右中叶支气管尺寸。

诊断标准与关键数值

  • 两名放射科医生采用半定量5分评分标准(-2为劣于、-1为稍劣于、0为等于、+1为稍优于、+2为优于常规剂量CT的ASIR)对MBIRSTND和MBIRRP20的气道树主观图像质量进行评分。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: We aimed to evaluate a new model-based iterative reconstruction (MBIRn) algorithm either with spatial resolution and noise reduction balance (MBIRSTND) or spatial resolution preference (MBIRRP20) for quantitative analysis of airway in low-dose chest computed tomography (CT) with a computer-aided detection (CAD) software, in comparison to adaptive statistical iterative reconstruction (ASIR) in routine-dose CT.

METHODS: Thirty patients who underwent both the routine-dose (noise index [NI] = 14 HU) and low-dose (at 30% level with NI = 28 HU) CT examination for pulmonary disease were included. Image acquisition was performed with 120 kVp tube voltage and automatic tube current modulation. Routine-dose scans were reconstructed with ASIR, whereas low-dose scans were reconstructed with ASIR, MBIRSTND, and MBIRRP20. Airway dimensions of the right middle lobe bronchus from the four reconstructions were measured using CAD software. Two radiologists used a semiquantitative 5 scoring criteria (-2, inferior to; +2, superior to; -1 slightly inferior to; +1, slightly superior to; and 0, equal to ASIR in routine-dose CT) to rate the subjective image quality of MBIRSTND and MBIRRP20 of airway trees. The paired t test and Wilcoxon signed-rank test were used for statistical comparison.

RESULTS: The low-dose CT provided 70.76% dose reduction compared to the routine-dose CT (0.88 ± 0.83 mSv vs 3.01 ± 1.89 mSv). MBIRSTND and MBIRRP20 with low-dose CT provided longer bronchial length measurements and were better in measurement variability and continuity and completeness of bronchial walls than ASIR in routine-dose CT (P < .05). MBIRSTND was better for subjective noise and MBIRRP20 for showing distal branches. CONCLUSIONS: MBIRSTND and MBIRRP20 algorithms provide better airway quantification at 30% of the radiation dose, compared to ASIR at routine-dose CT.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Jia Y, Ji X, He T, et al. Quantitative Analysis of Airway Tree in Low-dose Chest CT with a New Model-based Iterative Reconstruction Algorithm: Comparison to Adaptive Statistical Iterative Reconstruction in Routine-dose CT. Acad Radiol. 2018. PMID: 30017502. doi:10.1016/j.acra.2018.03.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。