经皮椎体成形术中的心内骨水泥栓塞:发生率、危险因素与临床管理
该单中心回顾性分析纳入1512例连续患者的1854次经皮椎体成形术,心内骨水泥栓塞发生率为3.9%(72例,92处栓塞),其中86.1%伴肺动脉骨水泥渗漏;有症状者6例(占所有心内栓塞的8.3%,占全部手术的0.32%),无死亡或永久后遗症;同次手术处理多个椎体是危险因素(OR 3.59),使用平板探测器技术发生率较低(OR 0.51)。
要点
- 心内骨水泥栓塞发生率为3.9%,有症状者仅占全部手术的0.32%且无永久后遗症。
- 同次手术处理多个椎体显著增加心内栓塞风险(OR 3.59,95%CI 1.98-6.51,p<0.001)。
- 使用平板探测器技术者心内栓塞发生率较低(OR 0.51,95%CI 0.32-0.83,p=0.007)。
核心结论
- 经皮椎体成形术后心内骨水泥栓塞发生率低(本研究为3.9%),相关有症状并发症罕见(0.3%),本系列中无导致临床后遗症者。
研究设计与样本
- 单中心回顾性分析,纳入1512例连续患者共1854次经皮椎体成形术,仅限胸椎或腰椎,使用低黏度聚甲基丙烯酸甲酯骨水泥在透视引导下操作。
关键影像表现/征象
- 心内骨水泥栓塞在72例患者中检出,共92处栓塞。
- 86.1%的病例同时检出肺动脉骨水泥渗漏。
- 有症状心内骨水泥栓塞6例,占所有心内栓塞的8.3%,占全部椎体成形术的0.32%。
诊断标准与关键数值
- 对临床高度怀疑心内骨水泥栓塞的患者,术后同日行胸部X线或CT检查,由两名放射科医师共识判读。
- 同次手术处理多个椎体与较高的心内栓塞率相关(OR 3.59,95%CI 1.98-6.51,p<0.001)。
- 使用平板探测器技术与较低的心内栓塞发生率相关(OR 0.51,95%CI 0.32-0.83,p=0.007)。
临床应用与阅片要点
- 术后对临床高度怀疑心内骨水泥栓塞者应同日行胸部X线或CT检查,并注意是否合并肺动脉骨水泥渗漏。
- 同次手术处理多个椎体时心内栓塞风险较高(OR 3.59),阅片时需留意心内及肺动脉内骨水泥影。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate the incidence and risk factors for ICE during a PV.
MATERIALS AND METHODS: Single-center retrospective analysis of 1512 consecutive patients who underwent 1854 PV procedures for osteoporotic (34 %), malignant (39.9 %) or other cause (26.1 %) of vertebral compression fractures (VCFs)/spine tumor lesions. Only thoracic or lumbar PVs were included. PVs were performed with polymethylmethacrylate (PMMA) low-viscosity bone cement under fluoroscopic guidance. Chest imaging (X-ray or CT) was performed the same day after PV in patients with high clinical suspicion of ICE. All post-procedural chest-imaging examinations were reviewed, and all ICEs were agreed upon in consensus by two radiologists.
RESULTS: ICEs were detected in 72 patients (92 cement embolisms). In 86.1 % of the cases, concomitant pulmonary artery cement leakage was detected. Symptomatic ICEs were observed in six cases (8.3% of all ICEs; 0.32% of all PV procedures). No ICE led to death or permanent sequelae. Multiple levels treated during the same PV session were associated with a higher ICE rate [OR: 3.59, 95% CI: (1.98-6.51); p < 0.001]; the use of flat panel technology with a lower ICE occurrence [OR: 0.51, 95% CI: (0.32-0.83); p = 0.007].
CONCLUSION: Intracardiac cement embolism after PV has a low incidence (3.9 % in our study). Symptomatic complications related to ICE are rare (0.3%); none was responsible for clinical sequelae in our series.
KEY POINTS: • The incidence of intracardiac cement embolism (ICE) during PVP is low (3.9%). • Having a high number of treated vertebrae during the same session is a significant risk factor for ICE. • Symptomatic intracardiac cement embolisms have a low incidence (8.3% of patients with ICE).
引用
- Fadili Hassani S, Cormier E, Shotar E, et al. Intracardiac cement embolism during percutaneous vertebroplasty: incidence, risk factors and clinical management. Eur Radiol. 2018. PMID: 30054794. doi:10.1007/s00330-018-5647-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。