使用包含扩散加权MRI的MRI检测复发性头颈部鳞状细胞癌的观察者间一致性
十名经验丰富的头颈放射科医生对10例临床怀疑(放)化疗后局部复发的头颈部鳞状细胞癌患者的随访MRI(含DW-MRI)进行两分类评估,观察者间一致性κ=0.55,观察者内一致性κ=0.80,既往经验和DW-MRI经验对评分无显著影响。
要点
- 基于DW-MRI评估HNSCC复发,观察者间一致性为中等(κ=0.55)。
- 同一观察者重复评估的一致性为基本一致至高度一致(κ=0.80)。
- 放射科经验和DW-MRI经验对评分无显著影响。
核心结论
- 使用DW-MRI评估(放)化疗后HNSCC复发时,观察者间一致性为中等(κ=0.55),观察者内一致性为基本一致(κ=0.80)。
研究设计与样本
- 10名经验丰富的头颈放射科医生对10例临床怀疑局部复发的HNSCC患者的随访MRI(含DW-MRI序列)进行两分类评估(局部复发或局部控制)。
- 患者为(放)化疗后临床怀疑复发的喉癌(n=3)、下咽癌(n=3)或口咽癌(n=4)。
- 采用Fleiss' Kappa评估观察者间一致性,采用Cohen's Kappa评估观察者内一致性。
诊断标准与关键数值
- 两分类决策量表:局部复发或局部控制。
- 观察者间一致性:κ=0.55(中等)。
- 观察者内一致性:κ=0.80(基本一致)。
- 既往放射科领域经验和DW-MRI经验对评分无显著影响。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
INTRODUCTION: For the detection of local recurrences of head and neck squamous cell carcinomas (HNSCC) after (chemo)radiation, diagnostic imaging is generally performed. Diffusion weighted magnetic resonance imaging (DW-MRI) has been proven to be able to adequately diagnose the presence of cancer. However evaluation of DW-MR images for recurrences is difficult and could be subject to individual interpretation.
AIM: To determine the interobserver agreement, intraobserver agreement and influence of experience of radiologists in the assessment of DW-MRI in patients clinically suspected of local recurrent HNSCC after (chemo)radiation.
METHODS: Ten experienced head and neck radiologists assessed follow-up MRI including DW-MRI series of 10 patients for the existence of local recurrence on a two point decision scale (local recurrence or local control). Patients were clinically suspected for a recurrence of laryngeal (n = 3), hypopharyngeal (n = 3) or oropharyngeal (n = 4) cancer after (chemo)radiation with curative intent. Fleiss' and Cohen's Kappa were used to determine interobserver agreement and intraobserver agreement, respectively.
RESULTS: Interobserver agreement was κ = 0.55. Intraobserver agreement was κ = 0.80. Prior experience within the field of radiology and with DW-MRI had no significant influence on the scoring.
CONCLUSION: For the assessment of HNSCC recurrence after (chemo)radiation by DW-MRI, moderate interobserver agreement and substantial intraobserver agreement was found.
引用
- Peltenburg B, Driessen JP, Philippens MEP, et al. The interobserver agreement in the detection of recurrent HNSCC using MRI including diffusion weighted MRI. Eur J Radiol. 2018. PMID: 30017269. doi:10.1016/j.ejrad.2018.05.031
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。