文献速递神经MR

多发性硬化患者每周注射钆布醇增强T1加权MRI:齿状核与苍白球信号强度是否增高

Weekly enhanced T1-weighted MRI with Gadobutrol injections in MS patients: Is there a signal intensity increase in the dentate nucleus and the globus pallidus?
PubMed 文献 · Eur J Radiol · 2018-06-19

研究纳入5例多发性硬化患者,连续8周每周注射大环类钆对比剂钆布醇后行增强3D T1加权成像,采用ROI法计算齿状核与小脑中脚、苍白球与半卵圆中心信号强度比值。结果显示8周期间两比值均无差异,提示多次密集注射大环类对比剂未导致齿状核和苍白球T1信号增高,作者据此认为大环类对比剂可能不引起脑内钆沉积,并提倡多发性硬化患者使用大环类而非线性对比剂。

要点

  • 5例多发性硬化患者每周注射钆布醇共8次,齿状核与小脑中脚、苍白球与半卵圆中心信号强度比值均无差异。
  • 作者认为大环类对比剂即使多次密集注射也可能不引起脑内钆沉积。
  • 作者提倡多发性硬化患者选用大环类对比剂而非线性对比剂。

核心结论

  • 每周连续注射大环类钆对比剂钆布醇8次,未伴随多发性硬化患者齿状核和苍白球T1信号增高;作者认为大环类对比剂即使多次密集注射也可能不引起脑内钆沉积,并提倡多发性硬化患者使用大环类而非线性对比剂。

研究设计与样本

  • 5例多发性硬化患者接受连续8周每周一次MRI扫描,采集钆布醇增强3D T1加权图像,采用ROI法计算齿状核与小脑中脚、苍白球与半卵圆中心信号强度比值,并用重复测量方差分析进行统计。

诊断标准与关键数值

  • 以齿状核与小脑中脚信号强度比值、苍白球与半卵圆中心信号强度比值作为评价指标,8周期间两比值均无差异。

局限性

  • 作者在结论中提出大环类对比剂可能不引起脑内钆沉积、并提倡多发性硬化患者使用大环类而非线性对比剂,该结论基于5例患者8周观察,原文未报告其他局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Gadolinium-based contrast agents (GBCAs) administration have drastically improved the accuracy of Multiple Sclerosis (MS) diagnosis by highlighting any damage to the brain blood barrier, thereby differentiating between active and non-active lesions. Following multiple administrations of GBCAs, several MS studies have reported a signal intensity (SI) increase on unenhanced T1-weighted images in certain brain regions such as the dentate nucleus (DN) and the globus pallidus (GP). Our aim was therefore to determine the accumulation of macrocyclic GBCAs on enhanced T1-weighted images SI in the DN and the GP of MS patients injected eight times.

MATERIALS AND METHODS: Five MS patients underwent eight weekly consecutive MRI scans. Enhanced 3D T1-weighted images with Gadobutrol as a macrocyclic GBCA, were acquired. A ROI-based approach was applied for the evaluation of SI in the DN to middle cerebellar peduncle (DN-MCP) and GP to semi-oval white matter (GP-SOWM) ratios. An analysis of variance on repeated measures was used for the statistical analysis of each ratio.

RESULTS: No DN-MCP and GP-SOWM SI ratio differences were observed over the eight-weeks period using the macrocyclic GBCA.

CONCLUSION: Iterative and weekly injections of macrocyclic GBCAs are not associated with T1 signal increase in the DN and GP of MS patients. These results would suggest a no gadolinium accumulation in the brain using macrocyclic GBCA even after several close injections and promote the use of a macrocylcic GBCA rather than linear agents for MS patients.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Jaulent P, Hannoun S, Kocevar G, et al. Weekly enhanced T1-weighted MRI with Gadobutrol injections in MS patients: Is there a signal intensity increase in the dentate nucleus and the globus pallidus? Eur J Radiol. 2018. PMID: 30017281. doi:10.1016/j.ejrad.2018.06.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。