文献速递心血管儿科影像MR

三维导航门控全心MRI与二维电影MRI在量化心室容积中的比较

Comparison between Three-Dimensional Navigator-Gated Whole-Heart MRI and Two-Dimensional Cine MRI in Quantifying Ventricular Volumes.
PubMed 文献 · Korean J Radiol · 2018-06-14

在110例先天性心脏病患者中,比较三维导航门控全心MRI与二维短轴电影MRI测量心室容积,三维全心MRI的收缩末期和舒张末期触发延迟均显著早于二维电影MRI,二维电影MRI显著高估左心室每搏量,三维全心MRI显著低估右心室每搏量。

要点

  • 三维全心MRI的收缩末期和舒张末期触发延迟均显著早于二维电影MRI。
  • 二维电影MRI显著高估左心室每搏量(8.7 ± 8.9 mL,p < 0.001)。
  • 三维全心MRI显著低估右心室每搏量(-22.7 ± 22.9 mL,p < 0.001)。

核心结论

  • 三维全心MRI常受舒张末期相位触发过早的影响,可能导致右心室每搏量低估。

研究设计与样本

  • 研究纳入110例先天性心脏病患者,采集导航门控三维全心MRI(收缩末期和舒张末期)、二维短轴电影MRI及大动脉相位对比MRI;三维全心MRI采用基于阈值的分割,二维电影MRI采用简化轮廓勾画;以相位对比MRI测得的动脉血流量为参考,比较心室容积计算的每搏量。

诊断标准与关键数值

  • 三维全心MRI与二维电影MRI的触发延迟比较:左心室收缩末期-16.8 ± 35.9 ms、舒张末期-59.0 ± 90.4 ms(p < 0.001);右心室收缩末期-58.8 ± 30.6 ms、舒张末期-104.9 ± 92.7 ms(p < 0.001)。
  • 与相位对比MRI动脉血流量比较:二维电影MRI显著高估左心室每搏量(8.7 ± 8.9 mL,p < 0.001);三维全心MRI显著低估右心室每搏量(-22.7 ± 22.9 mL,p < 0.001)。

局限性

  • 三维全心MRI常受舒张末期相位触发过早的影响,可能导致右心室每搏量低估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To test whether the method utilizing three-dimensional (3D) whole-heart MRI has an additional benefit over that utilizing conventional two-dimensional (2D) cine MRI in quantifying ventricular volumes.

MATERIALS AND METHODS: In 110 patients with congenital heart disease, a navigator-gated, 3D whole-heart MRI during end-systole (ES) and end-diastole (ED), 2D short-axis cine MRI, and phase contrast MRI of the great arteries were acquired. Ventricular volumes were measured by using a 3D threshold-based segmentation for 3D whole-heart MRI and by using a simplified contouring for 2D cine MRI. The cardiac trigger delays of 3D whole-heart MRI were compared with those of a 2D cine MRI. The stroke volumes calculated from the ventricular volumes were compared with the arterial flow volumes, measured by phase contrast MRI.

RESULTS: The ES and ED trigger delays of whole-heart MRI were significantly less than cine MRI for both the left ventricle (-16.8 ± 35.9 ms for ES, -59.0 ± 90.4 ms for ED; p < 0.001) and the right ventricle (-58.8 ± 30.6 ms for ES, -104.9 ± 92.7 ms for ED; p < 0.001). Compared with the arterial flow volumes, 2D cine MRI significantly overestimated the left ventricular stroke volumes (8.7 ± 8.9 mL, p < 0.001) and the 3D whole-heart MRI significantly underestimated the right ventricular stroke volumes (-22.7 ± 22.9 mL, p < 0.001).

CONCLUSION: Three-dimensional whole-heart MRI is often subject to early timing of the ED phase, potentially leading to the underestimation of the right ventricular stroke volumes.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Goo HW. Comparison between Three-Dimensional Navigator-Gated Whole-Heart MRI and Two-Dimensional Cine MRI in Quantifying Ventricular Volumes. Korean J Radiol. 2018. PMID: 29962876. doi:10.3348/kjr.2018.19.4.704

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。