基于多图谱自动分割小鼠危及器官
本研究针对临床前小动物放疗计划中危及器官手动勾画耗时的问题,开发并定量评估了一种基于多图谱的图像分割算法,用于九只健康小鼠的Microcone beam CT图像中六个危及器官的自动轮廓勾画,并与手动勾画比较。结果表明,对于脑和心脏等边界清晰的器官,自动与手动勾画一致性良好,中位DSC大于0.94;其他器官DSC较低但中位值仍可达0.69以上。结论认为该算法能以相对较高的准确度勾画六个危及器官。
要点
- 多图谱自动分割可勾画小鼠肾、眼、心、脑六个危及器官。
- 边界清晰的脑和心脏自动勾画与手动一致性良好,中位DSC大于0.94。
- 左眼、右眼、左肾、右肾中位DSC分别为大于0.74、0.69、0.89、0.80。
核心结论
- MABIS算法能够以相对较高的准确度勾画六个危及器官。
- 边界清晰的器官分割表现优于低对比度器官。
研究设计与样本
- 研究为方法开发与定量评估,纳入九只健康小鼠的Microcone beam CT图像。
- 采用本院开发的多图谱图像分割算法对肾脏、眼睛、心脏和脑六个危及器官进行自动勾画。
- 以手动勾画为参考,比较自动与手动轮廓,采用DSC、95百分位Hausdorff距离和质心位移三个定量指标。
诊断标准与关键数值
- 脑和心脏:中位DSC大于0.94,中位95百分位Hausdorff距离小于0.44 mm,中位质心位移小于0.20 mm。
- 左眼中位DSC大于0.74,右眼中位DSC为0.69,左肾中位DSC为0.89,右肾中位DSC为0.80。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE:: During the treatment planning of a preclinical small animal irradiation, which has time limitations for reasons of animal wellbeing and workflow efficiency, the time consuming organ at risk (OAR) delineation is performed manually. This work aimed to develop, demonstrate, and quantitatively evaluate an automated contouring method for six OARs in a preclinical irritation treatment workflow.
METHODS:: Microcone beam CT images of nine healthy mice were contoured with an in-house developed multiatlas-based image segmentation (MABIS) algorithm for six OARs: kidneys, eyes, heart, and brain. The automatic contouring was compared with the manual delineation using three quantitative metrics: the Dice Similarity Coefficient (DSC), 95th percentile Hausdorff Distance, and the centre of mass displacement.
RESULTS:: A good agreement between manual and automatic contouring was found for OARs with sharp organ boundaries. For the brain and the heart, the median DSC was larger than 0.94, the median 95th Hausdorff Distance smaller than 0.44 mm, and the median centre of mass displacement smaller than 0.20 mm. Lower DSC values were obtained for the other OARs, but the median DSC was still larger than 0.74 for the left eye, 0.69 for the right eye, 0.89 for the left kidney and 0.80 for the right kidney.
CONCLUSION:: The MABIS algorithm was able to delineate six OARs with a relatively high accuracy. Segmenting OARs with sharp organ boundaries performed better than low contrast OARs.
ADVANCES IN KNOWLEDGE:: A MABIS algorithm is developed, evaluated, and demonstrated in a preclinical small animal irradiation research workflow.
引用
- van der Heyden B, Podesta M, Eekers DB, et al. Automatic multiatlas based organ at risk segmentation in mice. Br J Radiol. 2018. PMID: 29975151. doi:10.1259/bjr.20180364
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。