应用扩散加权成像、磁共振波谱和磁敏感加权成像评估颅内结核瘤
本研究对116例已知或疑似中枢神经系统结核患者行常规MRI加DWI、MRS和SWI检查。结核瘤ADC值与转移瘤及高级别胶质瘤无显著差异,NAA/Cr和NAA/Cho比值与恶性脑病变无显著差异;但结核瘤Cho/Cr比值(1.36±0.41)显著低于恶性脑病变(2.63±0.99)。SWI显示42例结核瘤(58%)存在完整规则的外周低信号环,恶性脑病变均无此征象。
要点
- SWI完整规则外周低信号环见于42例结核瘤(58%),恶性脑病变均未见。
- 结核瘤Cho/Cr比值(1.36±0.41)显著低于恶性脑病变(2.63±0.99)。
- DWI的ADC值在结核瘤与转移瘤及高级别胶质瘤间无显著差异。
核心结论
- DWI在鉴别结核瘤与转移瘤及胶质瘤方面无明确优势;MRS的独特代谢物模式可鉴别结核瘤与转移瘤及胶质瘤;SWI出现完整规则外周低信号环支持结核瘤诊断。
研究设计与样本
- 研究纳入116例已知或疑似中枢神经系统结核患者,在常规MRI基础上行DWI、MRS和SWI先进MRI技术评估。
关键影像表现/征象
- SWI显示42例结核瘤(58%)存在完整规则的外周低信号环,恶性脑病变均无此征象。
- 结核瘤ADC值与转移瘤及高级别胶质瘤ADC值无显著差异(p > 0.05)。
- 结核瘤NAA/Cr和NAA/Cho比值与恶性脑病变无显著差异(p > 0.05)。
诊断标准与关键数值
- 结核瘤Cho/Cr比值为1.36±0.41,显著低于恶性脑病变的2.63±0.99。
- 结核瘤ADC值与转移瘤及高级别胶质瘤ADC值无显著差异(p > 0.05)。
- 结核瘤NAA/Cr和NAA/Cho比值与恶性脑病变无显著差异(p > 0.05)。
临床应用与阅片要点
- SWI出现完整规则外周低信号环支持结核瘤诊断,恶性脑病变未见此征象。
- MRS显示结核瘤Cho/Cr比值(1.36±0.41)显著低于恶性脑病变(2.63±0.99),可辅助鉴别。
- DWI的ADC值在结核瘤与转移瘤及高级别胶质瘤间无显著差异,鉴别价值有限。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE:: The present study was aimed to evaluate patients of suspected intracranial tuberculomas with diffusion-weighted imaging (DWI), magnetic resonance spectroscopy (MRS) and susceptibility-weighted imaging (SWI).
METHODS:: The present study evaluated 116 patients known or suspected of having central nervous system tuberculosis with advanced MRI techniques comprising of DWI, MRS and SWI in addition to the conventional MRI.
RESULTS:: Apparent diffusion coefficient value of tuberculomas was not significantly different (p > 0.05) from apparent diffusion coefficient value of metastatic lesions and high-grade gliomas. MRS revealed that NAA/Cr and NAA/Cho ratios of tuberculomas were not significantly different (p > 0.05) from that of malignant brain lesions. However, Cho/Cr ratio of tuberculomas (1.36 ± 0.41) was significantly lower from that of malignant brain lesions (2.63 ± 0.99). SWI revealed a complete and regular hypointense peripheral ring in 42 cases of tuberculomas (58%) and in none of the malignant brain lesions.
CONCLUSION:: DWI offers no clear advantage in differentiating tuberculomas from metastasis and gliomas. Tuberculomas may be differentiated from metastases and gliomas by their unique metabolite pattern on MRS. Presence of a complete and regular peripheral hypointense ring in SWI favors the diagnosis of tuberculomas.
ADVANCES IN KNOWLEDGE:: The results from the present study suggest promising role of SWI in the discrimination of tuberculomas from metastatic brain lesions and gliomas with the presence of a complete and regular peripheral hypointense ring favoring the diagnosis of tuberculomas.
引用
- Parry AH, Wani AH, Shaheen FA, et al. Evaluation of intracranial tuberculomas using diffusion-weighted imaging (DWI), magnetic resonance spectroscopy (MRS) and susceptibility weighted imaging (SWI). Br J Radiol. 2018. PMID: 29987985. doi:10.1259/bjr.20180342
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。