血管壁MRI环形增厚强化对颅内动脉瘤不稳定性的特异性高
该研究纳入2012年11月至2016年1月的263例患者共333个动脉瘤,在3T下行血管壁MRI,将强化分为0级无、1级局灶、2级薄环形、3级厚(>1 mm)环形四级。在未破裂动脉瘤(n=307)中,3级强化鉴别稳定与不稳定动脉瘤的特异度最高(84.4%;233/276),阴性预测值为94.3%(233/247),3级强化与动脉瘤不稳定性显著相关(P<.0001)。
要点
- 厚(>1 mm)环形强化(3级)鉴别不稳定动脉瘤特异度84.4%(233/276),阴性预测值94.3%(233/247)。
- 强化有无的阅片者间与阅片者内一致性κ值分别为0.82与0.87,强化分级一致性κ=0.92。
- 3级强化与动脉瘤不稳定性显著相关(P<.0001)。
核心结论
- 在颅内动脉瘤患者中,厚(>1 mm)环形管壁强化模式鉴别稳定与不稳定动脉瘤的特异度最高。
研究设计与样本
- 研究纳入2012年11月至2016年1月的患者,在3T下行血管壁MR成像,按稳定(偶然发现且6个月内无变化)或不稳定(有症状或6个月内变化)分组,采用0级无、1级局灶、2级薄环形、3级厚(>1 mm)环形四级强化分类评估,共纳入263例患者333个动脉瘤。
诊断标准与关键数值
- 强化分级:0级无强化,1级局灶强化,2级薄环形强化,3级厚(>1 mm)环形强化;未破裂动脉瘤(n=307)中3级强化鉴别稳定与不稳定病变特异度84.4%(233/276;95% CI:80.1%,88.7%;P=.02),阴性预测值94.3%(233/247)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To identify wall enhancement patterns on vessel wall MRI that discriminate between stable and unstable unruptured intracranial aneurysm (UIA). Materials and Methods Patients were included from November 2012 through January 2016. Vessel wall MR images were acquired at 3 T in patients with stable (incidental and nonchanging over 6 months) or unstable (symptomatic or changing over 6 months) UIA. Each aneurysm was evaluated by using a four-grade classification of enhancement: 0, none; 1, focal; 2, thin circumferential; and 3, thick (>1 mm) circumferential. Inter- and intrareader agreement for the presence and the grade of enhancement were assessed by using κ statistics and 95% confidence interval (CI). The sensitivity, specificity, and negative and positive predictive values of each enhancement grade for differentiating stable from unstable aneurysms was compared. Results The study included 263 patients with 333 aneurysms. Inter- and intrareader agreement was excellent for both the presence of enhancement (κ values, 0.82 [95% CI: 0.67, 0.99] and 0.87 [95% CI: 0.7, 1.0], respectively) and enhancement grade (κ = 0.92 [95% CI: 0.87, 0.95]). In unruptured aneurysms (n = 307), grade 3 enhancement exhibited the highest specificity (84.4%; 233 of 276; 95% CI: 80.1%, 88.7%; P = .02) and negative predictive value (94.3%; 233 of 247) for differentiating between stable and unstable lesions. There was a significant association between grade 3 enhancement and aneurysm instability (P < .0001). Conclusion In patients with intracranial aneurysm, a thick (>1 mm) circumferential pattern of wall enhancement demonstrated the highest specificity for differentiating between stable and unstable aneurysms. © RSNA, 2018.
引用
- Edjlali M, Guédon A, Ben Hassen W, et al. Circumferential Thick Enhancement at Vessel Wall MRI Has High Specificity for Intracranial Aneurysm Instability. Radiology. 2018. PMID: 29969070. doi:10.1148/radiol.2018172879