文献速递儿科影像神经MR

死后新生儿高分辨率各向同性扩散成像:可行性研究

High resolution isotropic diffusion imaging in post-mortem neonates: a feasibility study.
PubMed 文献 · Br J Radiol · 2018-08-30

本研究在12例平均胎龄33.4周(范围29-37周)的新生儿中,于3T和1.5T下行死后脑与全身扩散加权成像,评估先进扩散序列的可行性。结果显示,采用多带多层面扩散序列的3T图像质量较1.5T临床方案显著提高,除b=250 s/mm²外各b值视觉评分均显著更高(p<0.001)。作者认为该多层面多带定量扩散序列在围产期死后场景中可行,未来可支持更详细和定量的临床死后MRI研究。

要点

  • 3T多带多层面扩散序列(TE 53.4 ms,TR 5600 ms,1.8 mm各向同性,multiband factor 2)在死后新生儿全身扩散成像中图像质量优于1.5T临床方案。
  • 1.5T扩散加权成像视觉评分较差(均值2.4,SD±0.47),3T各b值除b=250 s/mm²外评分均显著更高(p<0.001)。
  • 该序列在围产期死后场景中展示可行性,支持未来更详细和定量的扩散MRI临床死后研究。

核心结论

  • 利用更高场强和梯度性能的扩散序列与硬件进步,可实现高分辨率全身扩散死后MRI,图像质量较当前临床方法改善;多层面多带定量扩散序列在围产期死后场景中可行。

研究设计与样本

  • 可行性研究,纳入12例新生儿,平均胎龄33.4周(范围29-37周),在3T和1.5T下行死后脑与全身MRI。

诊断标准与关键数值

  • 1.5T方案:双极扩散编码、单次激发自旋回波平面回波成像(SE-EPI),TE 96 ms,TR 2700 ms,层内体素1.8×1.8 mm,层厚5 mm,b值500和1000 s/mm²,三个正交方向,总采集时间2:12。
  • 3T方案:单极扩散编码、同时多层面EPI,12个均匀分布方向,TE 53.4 ms,TR 5600 ms,1.8 mm各向同性,multiband factor 2,b值250、750、1250和1750 s/mm²,单个b值采集时间2:09。
  • 图像质量视觉评分:1.5T扩散加权成像均值2.4(SD±0.47),3T各b值除b=250 s/mm²(差异无统计学显著)外评分均显著更高(p<0.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE:: To investigate the potential of advanced diffusion weighted imaging (DWI) in post-mortem MRI (PMMR) at 3T.

METHODS:: We acquired PMMR brain and body imaging in 12 neonates, mean gestational age 33.4 weeks (range 29-37 weeks) at 3T and 1.5T. Head and body diffusion imaging at 1.5T consisted of bipolar diffusion encoding and single-shot spin-echo echo-planar imaging (SE-EPI) for acquisition (echo time (TE) 96 ms; repetition time (TR) 2700 ms; voxel size 1.8 x 1.8 mm in-plane with slice thickness 5 mm; b-values of 500 and 1000 s/mm2 applied in three orthogonal directions; total acquisition time 2:12). A whole-body 3T diffusion imaging protocol using monopolar diffusion encoding and simultaneous multislice EPI acquisition with gradients applied in 12 uniformly distributed directions was obtained (TE 53.4 ms; TR 5600 ms; 1.8 mm isotropic; multiband factor 2; b-values of 250, 750, 1250 and 1750 s/mm2; acquisition time 2:09 for a single b-value).

RESULTS:: There was significant improvement in image quality in multiband, multislice diffusion PMMR protocol. On visual assessment of image quality, 1.5T DWI scored poorly (mean 2.4 SD ± 0.47), and all 3T b-values individually scored significantly higher (p < 0.001) apart from b = 250 s/mm2 which was not significantly different.

CONCLUSION:: Recent advances in diffusion sequences and hardware utilising higher field strengths and gradient performance allows whole-body diffusion PMMR imaging at high resolution with improved image quality compared to the current clinical approach.