血流导向装置治疗急性破裂颅内动脉瘤:系统综述与荟萃分析
该系统综述与荟萃分析纳入20项研究共223例急性破裂颅内动脉瘤患者,评估血流导向装置治疗后的结局。结果显示长期完全/近完全闭塞率为88.9%,治疗相关并发症率为17.8%,动脉瘤再出血率为4%;后循环及多支架治疗的并发症率更高。作者认为前循环破裂动脉瘤在其他方法不可行时可有效使用血流导向技术并减少支架数量,后循环仅限其他治疗不可行的精选病例。
要点
- 急性破裂颅内动脉瘤血流导向治疗后长期完全/近完全闭塞率为88.9%(162/189)。
- 治疗相关并发症率为17.8%(42/223),后循环27%高于前循环11.7%(P = .004)。
- 多支架治疗并发症率26%高于单支架10%(P = .004),再出血率为4%。
核心结论
- 血流导向装置治疗破裂颅内动脉瘤可获得较高的长期血管造影闭塞率(88.9%)和较低的再出血率(4%),但治疗相关并发症率为18%;前循环破裂动脉瘤在其他策略不可行时可有效使用血流导向技术并尽量减少支架数量,后循环因并发症率27%仅应考虑用于其他治疗不可行的精选病例。
研究设计与样本
- 系统综述与荟萃分析,系统检索3个数据库2006至2018年发表的文献,按PRISMA指南纳入2010至2018年报告血流导向装置治疗急性破裂颅内动脉瘤的研究,共纳入20项研究、223例患者,采用随机效应模型合并动脉瘤闭塞率、并发症、再出血及影响因素。
诊断标准与关键数值
- 即刻血管造影闭塞率为32%(29/86;95% CI,15.4%-48%;I2 = 79.6%);长期完全/近完全闭塞率为88.9%(162/189;95% CI,84%-93.5%;I2 = 20.9%),平均影像随访9.6个月;治疗相关并发症率为17.8%(42/223;95% CI,11%-24%;I2 = 52.6%),后循环为27%(16/72;95% CI,14%-40%;I2 = 66%)高于前循环11.7%(18/149;95% CI,7%-16%;I2 = 0%)(P = .004),多支架为26%(14/52;95% CI,14%-45%;I2 = 59%)高于单支架10%(20/141;95% CI,5%-15%;I2 = 0%)(P = .004);动脉瘤再出血率为4%(5/223;95% CI,1.8%-7%;I2 = 0%),前72小时内更高。
临床应用与阅片要点
- 作者认为当弹簧圈栓塞或显微外科夹闭不可行时,前循环破裂动脉瘤可有效采用血流导向技术治疗,并尽量减少支架数量;鉴于并发症率27%,后循环破裂动脉瘤的血流导向治疗仅应考虑用于其他治疗不可行的精选病例。
局限性
- 纳入研究多为小样本和回顾性系列。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: The implantation of flow-diverter stents for the treatment of ruptured intracranial aneurysms required further investigation.
PURPOSE: Our aim was to analyze the outcomes after flow diversion of ruptured intracranial aneurysms.
DATA SOURCES: A systematic search of 3 databases was performed for studies published from 2006 to 2018.
STUDY SELECTION: According to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, we included studies (from 2010 to 2018) reporting acutely ruptured intracranial aneurysms treated with flow diversion.
DATA ANALYSIS: Random-effects meta-analysis was used to pool the following: aneurysm occlusion rate, complications, rebleeding, and factors influencing the studied outcomes.
DATA SYNTHESIS: We included 20 studies evaluating 223 patients with acutely ruptured intracranial aneurysms treated with flow-diverter stents. Immediate angiographic occlusion was obtained in 32% (29/86; 95% CI, 15.4%-48%; I2 = 79.6%) of aneurysms, whereas long-term complete/near-complete aneurysm occlusion was 88.9% (162/189; 95% CI, 84%-93.5%; I2 = 20.9%) (mean radiologic follow-up of 9.6 months). The treatment-related complication rate was 17.8% (42/223; 95% CI, 11%-24%; I2 = 52.6%). Complications were higher in the posterior circulation (16/72 = 27%; 95% CI, 14%-40%; I2 = 66% versus 18/149 = 11.7%; 95% CI, 7%-16%; I2 = 0%) (P = .004) and after treatment with multiple stents (14/52 = 26%; 95% CI, 14%-45%; I2 = 59%) compared with a single stent (20/141 = 10%; 95% CI, 5%-15%; I2 = 0%) (P = .004). Aneurysm rebleeding after treatment was 4% (5/223; 95% CI, 1.8%-7%; I2 = 0%) and was higher in the first 72 hours.
LIMITATIONS: Small and retrospective series.
CONCLUSIONS: Flow-diversion treatment of ruptured intracranial aneurysms yields a high rate of long-term angiographic occlusion with a relatively low rate of aneurysm rebleeding. However, treatment is associated with a complication rate of 18%. When coiling or microsurgical clipping are not feasible strategies, anterior circulation ruptured aneurysms can be effectively treated with a flow-diversion technique, minimizing the number of stents deployed. Given the 27% rate of complications, flow diversion for ruptured posterior circulation aneurysms should be considered only in selected cases not amenable to other treatments.
引用
- Cagnazzo F, di Carlo DT, Cappucci M, et al. Acutely Ruptured Intracranial Aneurysms Treated with Flow-Diverter Stents: A Systematic Review and Meta-Analysis. AJNR Am J Neuroradiol. 2018. PMID: 30049721. doi:10.3174/ajnr.A5730
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。