文献速递腹部技术与安全CT

亚毫西弗CT结肠成像:基于知识的迭代重建对结肠息肉检出效果的影响

Sub-millisievert CT colonography: effect of knowledge-based iterative reconstruction on the detection of colonic polyps.
PubMed 文献 · Eur Radiol · 2018-06-08

49例患者行超低剂量CT结肠成像(仰卧位100 kVp/20 mAs,俯卧位80 kVp/20 mAs),同日结肠镜对照,图像分别用滤波反投影(FBP)和基于知识的迭代重建(IMR)重建。IMR对≥10 mm息肉的总敏感度(69.5%)显著高于FBP(52.4%,p<0.001),图像噪声显著降低且图像质量更优。

要点

  • 亚毫西弗CTC采用IMR重建对≥10 mm息肉的总敏感度为69.5%。
  • IMR对≥10 mm息肉的敏感度显著高于FBP(69.5% vs 52.4%,p<0.001)。
  • IMR图像噪声(8.4±6.2 HU)显著低于FBP(37.5±13.9 HU)。

核心结论

  • 亚毫西弗CTC采用IMR重建对临床显著息肉的检出是可行的,对≥10 mm息肉显示70%的总敏感度,同时较FBP显著降低噪声并改善图像质量。

研究设计与样本

  • 前瞻性纳入49例患者,行超低剂量CTC(仰卧位100 kVp/20 mAs,俯卧位80 kVp/20 mAs),同日行结肠镜,图像用FBP和IMR(Philips Healthcare, Best, Netherlands)重建,由三名放射科医生评估。

诊断标准与关键数值

  • 对6.0-9.9 mm息肉(n=22),IMR总敏感度36/66(54.5%)与FBP 34/66(51.5%)无显著差异(p=0.414)。
  • 对≥10 mm息肉(n=35),IMR总敏感度73/105(69.5%)显著高于FBP 55/105(52.4%)(p<0.001)。
  • 在中等和经验较少的审阅者中,IMR与FBP对≥10 mm息肉的敏感度差异有统计学意义(p=0.014和p=0.003)。
  • IMR平均图像噪声8.4±6.2 HU,FBP为37.5±13.9 HU,IMR显著更低(p<0.001)。
  • 所有审阅者对所有评估节段的图像质量评分,IMR均显著优于FBP(所有p<0.001)。

临床应用与阅片要点

  • 原文结论认为亚毫西弗CTC采用IMR重建对临床显著息肉的检出是可行的。
  • IMR较FBP显著降低图像噪声并改善图像质量。
  • 原文未据此给出具体的阅片或报告推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To assess the feasibility of ultra-low dose computed tomography colonography (CTC) using knowledge-based iterative reconstruction (IR) and to determine its effect on polyp detection.

METHODS: Forty-nine prospectively-enrolled patients underwent ultra-low dose CTC in the supine (100 kVp/20 mAs) and prone positions (80 kVp/20 mAs), followed by same-day colonoscopy. Thereafter, images were reconstructed using filtered back projection (FBP) and knowledge-based IR (IMR; Philips Healthcare, Best, Netherlands) algorithms. Effective radiation dose of CTC was recorded. Pooled per-polyp sensitivity and positive predictive value of three radiologists was analysed and compared between FBP and IMR. Image quality was assessed on a five-point scale and image noise was recorded using standard deviations.

RESULTS: Mean effective radiation dose of ultra-low dose CTC was 0.90 ± 0.06 mSv. Eighty-nine polyps were detected on colonoscopy (mean, 8.5 ± 4.7 mm). The pooled per-polyp sensitivity for polyps 6.0-9.9 mm (n = 22) on CTC reconstructed with IMR (36/66, 54.5%) was not significantly different with that using FBP algorithm (34/66, 51.5%) (p = 0.414). For polyps ≥10 mm (n = 35), however, the pooled per-polyp sensitivity on CTC with IMR (73/105, 69.5%) was significantly higher than that with FBP (55/105, 52.4%) (p < 0.001). In particular, the difference of per-polyp sensitivity was statistically significant in intermediate (p = 0.014) and novice (p = 0.003) reviewers. Furthermore, mean image noise of IMR (8.4 ± 6.2 HU) was significantly lower than that of FBP (37.5 ± 13.9 HU) (p < 0.001) and image quality with IMR was significantly better than with FBP in all evaluated segments in all reviewers (all ps < 0.001).

CONCLUSIONS: Sub-mSv CTC reconstructed with IMR was feasible for the detection of clinically significant polyps, demonstrating 70% per-polyp sensitivity of polyps ≥10 mm, while allowing significant noise reduction and improvement in image quality compared with FBP reconstruction.

KEY POINTS: • Sub-mSv CTC using IMR demonstrated 70% per-polyp sensitivity for polyps ≥10 mm. • CTC using IMR significantly outperformed CTC reconstructed with FBP. • IMR allows significantly more noise reduction and improvement in image quality than FBP.

来源:Eur Radiol,查看原文。版权归原作者所有。